Page 733 of 3061
BL-22
< SERVICE INFORMATION >
POWER DOOR LOCK SYSTEM
WIWA2045E
Page 734 of 3061
POWER DOOR LOCK SYSTEM
BL-23
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
Terminal and Reference Value for BCMINFOID:0000000003532899
Refer to BCS-11, "Terminal and Reference Value for BCM".
Work FlowINFOID:0000000003532900
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-15, "
System Description".
WIWA2046E
Page 735 of 3061

BL-24
< SERVICE INFORMATION >
POWER DOOR LOCK SYSTEM
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-25,
"Trouble Diagnosis Symptom Chart".
4. Does power door lock system operate normally? OK: GO TO 5, NG: GO TO 3.
5. Inspection End.
CONSULT-II Function (BCM)INFOID:0000000003532901
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT–II START PROCEDURE
Refer to GI-36, "CONSULT-II Start Procedure".
DATA MONITOR
ACTIVE TEST
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Monitor item "OPERATION" Content
KEY ON SW "ON/OFF" Indicates [ON/OFF] condition of key switch.
CDL LOCK SW "ON/OFF" Indicates [ON/OFF] condition of lock signal from lock/unlock switch LH and RH.
CDL UNLOCK SW "ON/OFF" Indicates [ON/OFF] condition of unlock signal from lock/unlock switch LH and RH.
KEY CYL LK-SW "ON/OFF" Indicates [ON/OFF] condition of lock signal from key cylinder.
KEY CYL UN-SW "ON/OFF" Indicates [ON/OFF] condition of unlock signal from key cylinder.
IGN ON SW "ON/OFF" Indicates [ON/OFF] condition of ignition switch.
DOOR SW–DR "ON/OFF" Indicates [ON/OFF] condition of front door switch LH.
DOOR SW–AS "ON/OFF" Indicates [ON/OFF] condition of front door switch RH.
DOOR SW–RR "ON/OFF" Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW–RL "ON/OFF" Indicates [ON/OFF] condition of rear door switch LH.
BACK DOOR SW "ON/OFF" Indicates [ON/OFF] condition of back door latch (door ajar switch).
KEYLESS LOCK "ON/OFF" Indicates [ON/OFF] condition of lock signal from keyfob.
KEYLESS UNLOCK "ON/OFF" Indicates [ON/OFF] condition of unlock signal from keyfob.
Test item Content
ALL LOCK/UNLOCKThis test is able to check all door lock actuators lock operation. These actuators lock when "ON"
on CONSULT–II screen is touched.
DR UNLOCKThis test is able to check front door lock assembly LH (actuator) unlock operation.These actu-
ators lock when "ON" on CONSULT–II screen is touched.
OTHER UNLOCKThis test is able to check door lock actuators [except front door lock assembly LH (actuator)]
unlock operation.These actuators unlock when "ON" on CONSULT–II screen is touched.
Page 736 of 3061

POWER DOOR LOCK SYSTEM
BL-25
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
Trouble Diagnosis Symptom ChartINFOID:0000000003532902
BCM Power Supply and Ground Circuit InspectionINFOID:0000000003532903
Refer to BCS-15, "BCM Power Supply and Ground Circuit Inspection".
Door Switch CheckINFOID:0000000003532904
1.CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-II
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR", "BACK DOOR
SW") in DATA MONITOR mode with CONSULT–II.Refer to BL-24, "
CONSULT-II Function (BCM)".
• When doors are open:
• When doors are closed:
Symptom Repair order Refer to page
Key reminder door function does not operate prop-
erly.1. Door switch checkBL-25
2. Key switch (insert) checkBL-27
3. Replace BCM.BCS-24
Power door lock does not operate with door lock
and unlock switch on main power window and
door lock/unlock switch or power window and door
lock/unlock switch RH.1. Door lock/unlock switch checkBL-28
2. Replace BCM.BCS-24
Front door lock assembly LH (actuator) does not
operate.1. Front door lock assembly LH (Actuator) checkBL-32
Specific door lock actuator does not operate.1. Front door lock actuator RH checkBL-322. Rear door lock actuator RH/LH checkBL-33
Power door lock does not operate with front door
key cylinder LH operation.1. Front door lock assembly LH (key cylinder
switch) checkBL-35
2. Replace BCM.BCS-24
Power door lock does not operate.1. BCM power supply and ground circuit checkBCS-152. Door lock/unlock switch checkBL-28
Back door opener does not operate.1. Back door power supply and ground circuit in-
spectionBL-952. Door switch checkBL-25
3. Power liftgate switch system inspectionBL-95
Glass hatch lock actuator does not operate
(RF door must be unlocked for normal operation).1. Glass hatch switch checkBL-302. Glass hatch lock actuator checkBL-34
3. Replace BCM.BCS-24
DOOR SW-DR : ON
DOOR SW-AS : ON
DOOR SW-RL : ON
DOOR SW-RR : ON
BACK DOOR SW : ON
DOOR SW-DR : OFF
DOOR SW-AS : OFF
DOOR SW-RL : OFF
LIIA0665E
Page 737 of 3061

BL-26
< SERVICE INFORMATION >
POWER DOOR LOCK SYSTEM
Without CONSULT-II
Check voltage between BCM connector M18 or M19 terminals 12,
13, 43, 47, 48 and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.
2.CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH), B18 (rear LH), B116
(rear RH) terminal 2 or back door latch connector (C) D503 terminal 7 and BCM connectors (A) M18, M19
terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH), B18 (rear LH), B116 (rear RH) terminal 2
or back door latch connector (C) D503 terminal 7 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.CHECK DOOR SWITCHES
FRONT AND REAR DOORSDOOR SW-RR : OFF
BACK DOOR SW : OFF
Connector ItemTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19Back door
latch (door
ajar switch)43
GroundOpen
↓
Closed0
↓
Battery voltage Front door
switch LH47
Rear door
switch LH48
M18Front door
switch RH12
Rear door
switch RH13
LIIA1041E
2 - 12 : Continuity should exist.
2 - 13 : Continuity should exist.
2 - 47 : Continuity should exist.
2 - 48 : Continuity should exist.
7 - 43 : Continuity should exist.
2 - Ground : Continuity should not exist.
7 - Ground : Continuity should not exist.
WIIA0750E
Page 738 of 3061

POWER DOOR LOCK SYSTEM
BL-27
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
Check continuity between front or rear door switch terminal 2 and
exposed metal of switch while pressing and releasing switch.
BACK DOOR
Check continuity between back door latch connector (A) D503 termi-
nals 7 and 8 while pressing (closing back door) and releasing (open-
ing back door) switch.
OK or NG
OK >> (Front and rear doors) Switch circuit is OK.
OK >> (Back door) GO TO 4.
NG >> Replace door switch.
4.CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Key Switch (Insert) CheckINFOID:0000000003532905
1.CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-24, "
CONSULT-II
Function (BCM)".
• When key is inserted to ignition key cylinder:
• When key is removed from ignition key cylinder:
Without CONSULT-IIDoor switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
WIIA0644E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA0752E
8 - Ground : Continuity should exist.
LIIA0828E
KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
Page 739 of 3061

BL-28
< SERVICE INFORMATION >
POWER DOOR LOCK SYSTEM
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2.CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.
Door Lock/Unlock Switch CheckINFOID:0000000003532906
1.CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
With CONSULT-II
Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in DATA MONITOR mode in CON-
SULT–II. Refer to BL-24, "
CONSULT-II Function (BCM)"
• When door lock/unlock switch is turned to LOCK:
• When door lock/unlock switch is turned to UNLOCK:
Without CONSULT-II
1. Remove key from ignition key cylinder.
2. Check the signal between BCM connector M18 terminal 22 and ground with oscilloscope when door lock/
unlock switch is turned to LOCK or UNLOCK.
3. Make sure the signals which are shown in the figure below can be detected during 10 seconds just after
the door lock/unlock switch is turned to LOCK or UNLOCK.
ConnectorTe r m i n a l s
Condition Voltage (V)
(+) (–)
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E
CDL LOCK SW :ON
CDL UNLOCK SW :ON
PIIA6538E
Page 740 of 3061

POWER DOOR LOCK SYSTEM
BL-29
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
OK or NG
OK >> Door lock and unlock switch circuit is OK.
NG >> GO TO 2.
2.CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch
RH
3. Check continuity between main power window and door lock/
unlock switch connector D8 terminal 17 and ground.
4. Check continuity between power window and door lock/unlock
switch RH connector D105 terminal 11 and ground
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.CHECK POWER WINDOW BUS CIRCUIT FOR OPEN
1. Disconnect BCM.
2. Check continuity between BCM connector M18 terminal 22 and
main power window and door lock/unlock switch connector D7
terminal 14.
ConnectorTe r m i n a l s
Voltage (V)
(+) (–)
M18 22 Ground
PIIA6379EPIIA1297E
17 - Ground : Continuity should exist.
LIIA0392E
11 - Ground : Continuity should exist.
LIIA1140E
22 - 14 : Continuity should exist.
LIIA0394E