Downloaded from www.Manualslib.com manuals search engine 10B-29 Body Electrical Control System:
5) Disconnect connectors from BCM and junction
block.
6) Detach wiring harness clamp from junction block.
Installation
Reverse removal procedure for installation, noting
following points.
• Connect connectors securely.
• Enable air bag system referring to “Enabling Air Bag
System in Section 8B”.
• With keyless entry system (other than keyless start
model), if BCM is replaced, register transmitter code
into BCM, referring to “Programming Transmitter
Code for Keyless Entry System (Other than Keyless
Start Model) in Section 9F”.
Security Alarm Mode Selection Procedure (If
Equipped)
S6RW0DA206005
Security alarm mode can be selected by performing the
following procedure.
1) Confirm that all doors are closed, all doors are
unlocked and ignition key is inserted in ignition key
cylinder.
2) Remove ignition key from ignition key cylinder.
3) Perform Step a) through e) described below within
15 seconds.
a) Insert ignition key (1) in ignition key cylinder (2).
b) Remove ignition key from ignition key cylinder.
c) Repeat Step a) and b) twice.
d) Insert ignition key in ignition key cylinder.
e) Push lock side (3) of driver side manual lock
switch (4) 3 times.4) When Step 3) is completed, the mode changes to
the next one automatically. The warning buzzer
(located in BCM) sounds by the number of specified
for each mode as follows.
• Changed from A mode to B mode: Buzzer sounds
4 times
• Changed from B mode to A mode: Buzzer sounds
once
Outside Air Temperature Sensor Removal and
Installation
S6RW0DA206002
For removal and installation, refer to “Outside Air
Temperature Sensor Removal and Installation (If
Equipped) in Section 9C”.
Outside Air Temperature Sensor InspectionS6RW0DA206003
For inspection, refer to “Outside Air Temperature Sensor
Inspection (If Equipped) in Section 9C”.
Special Tools and Equipment
Special ToolS6RW0DA208001
1 2
4
3
I7JB01A20007-01
SUZUKI scan tool
—
This kit includes following
items. 1. Tech 2, 2. PCMCIA
card, 3. DLC cable, 4. SAE
16/19 adapter, 5. Cigarette
cable, 6. DLC loop back
adapter, 7. Battery power
cable, 8. RS232 cable, 9.
RS232 adapter, 10. RS232
loop back connector, 11.
Storage case, 12. )
Downloaded from www.Manualslib.com manuals search engine 10E-14 Keyless Start System:
Keyless Start System Operation InspectionS6RW0DA504011
Keyless Engine Start Operation
1) Sit in driver seat with remote controller carried with
you.
2) Check that all doors are closed and ignition key is
not inserted in ignition key cylinder.
3) While pushing ignition knob switch (1) of steering
lock unit, check if ignition knob switch can be turned
from its lock position.
If key indicator light (2) in combination meter lights in
blue and ignition knob switch can be turned from its
lock position in this check, keyless engine start
operation is in good condition.
If key indicator light in combination meter lights in red
and ignition knob switch cannot be turned from its
lock position in this check, go to “Keyless Start
System Check”.
NOTE
Pushing ignition knob switch for 5 seconds
or longer causes function to protect steering
lock releasing solenoid against heat to work.
Then steering lock unit stops energizing
solenoid, preventing ignition knob switch
from turning. At the same time, key indicator
light in combination meter turns off. In such
case, take your hand off from ignition knob
switch once and operate it again.
Door Lock Operation (Keyless Start System)S6RW0DA504012
1) Check that all door locks are released and all doors
are closed.
2) With remote controller of which ID code is registered
in keyless start control module carried with yourself,
check that pushing driver door request switch once
locks all doors.
3) Check that pushing request switch of driver door,
passenger door or rear end door once releases
corresponding door lock.
4) Check that pushing again request switch pushed in
Step 3) releases all door locks.
NOTE
If door of which request switch has been
pushed is opened/closed before performing
Step 4), all door locks will not be released
even when Step 4) is performed. If Step 4) is
performed after door is opened/closed, only
the door of which request switch was pushed
will be locked.
Inspection of Keyless Start Control Module and
Its Circuits
S6RW0DA504013
Keyless start control module and its circuits can be
checked at keyless start control module wiring couplers
by measuring voltage and resistance.
CAUTION!
Keyless start control module cannot be
checked by itself. It is strictly prohibited to
connect voltmeter or ohmmeter to keyless
start control module with coupler
disconnected from it.
1 2
I4RS0BA50012-01
I4RS0BA50013-01