MERCEDES-BENZ SPRINTER 2006  Service Manual REVERSE GEAR POWERFLOW - LIMP IN
Fig. 14 Reverse Gear Powerflow - Limp In or 4WD Low Range
1 - TORQUE CONVERTER LOCK-UP CLUTCH 14 - CENTER PLANETARY CARRIER
2 - TORQUE CONVERTER TURBINE 15 - REAR PLAN

Page 1766 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Torque from the torque converter is increased via
the input shaft (25) and all three planetary gearsets
and transferred with reversed direction of rotation to
the output shaft (26) (Fig. 14) and (Fig.

Page 1767 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual SHIFT GROUPS/ SHIFT SEQUENCE
1-2 Shift - First Gear Engaged
Fig. 16 First Gear Engaged
1 - 1-2/4-5 SHIFT SOLENOID 5 - 1-2/4-5 COMMAND VALVE
2 - 1-2/4-5 OVERLAP VALVE 6 - DRIVING CLUTCH K1
3 - 1-2/4-5

Page 1768 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual The end face of the command valve (5) (Fig. 16) is
kept unpressurized via the solenoid valve for 1-2 and
4-5 shift (1). Because of the holding pressure shift
valve (4), the working pressure (p-A) is p

Page 1769 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Shift Phase - 1-2 Shift Phase 1
When the 1-2 and 4-5 shift solenoid valve (1) (Fig.
17) is turned on, the shift valve pressure (p-SV) is
directed onto the end face of the command valve (5).The command

Page 1770 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual directed via the command valve (5) onto clutch K1
(6).
Simultaneously the clutch B1 (7) is subjected to
overlap pressure by the overlap regulating valve (2).
The pressure in the clutch B1 (7) as it di

Page 1771 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Shift Phase - 1-2 Shift Phase 2
The B1 (7) (Fig. 18) pressure acting on the end face
of the shift pressure shift valve (3) is replaced by the
working pressure (p-A). The shift pressure is alsorouted t

Page 1772 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Second Gear Engaged
After the gearchange is complete, the pressure on
the end face of the command valve (5) (Fig. 19) is
reduced via the 1-2 and 4-5 shift solenoid valve (1),and the command valve (5)