INFINITI FX35 2004  Service Manual LT-158
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
When inserted the key plate to key switch, power is supplied (with intelligent key system)
through the key switch and ignition knob sw

Page 3714 of 4449

INFINITI FX35 2004  Service Manual INTERIOR ROOM LAMP
LT-159
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
SWITCH OPERATION
When driver door switch is ON (door is opened), ground is supplied
through BCM terminal 1


Page 3715 of 4449

INFINITI FX35 2004  Service Manual LT-160
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
through key switch terminal 1
to BCM terminal 37.
When key is removed from key switch (key switch OFF), power supply to BCM terminal

Page 3727 of 4449

INFINITI FX35 2004  Service Manual LT-172
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
Terminals and Reference Values for BCMAKS007FB
Terminal
No.Wire 
colorSignal nameMeasuring condition
Reference value
Ignition 
switchOp

Page 3728 of 4449

INFINITI FX35 2004  Service Manual INTERIOR ROOM LAMP
LT-173
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
How to Proceed With Trouble DiagnosisAKS007FC
1. Confirm the symptom or customer complaint.
2. Understand ope

Page 3732 of 4449

INFINITI FX35 2004  Service Manual INTERIOR ROOM LAMP
LT-177
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
2. ACTIVE TEST
1. Select “BCM” on CONSULT-II. Select “INT LAMP” active test.
2. When interior room la

Page 3733 of 4449

INFINITI FX35 2004  Service Manual LT-178
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
6. CHECK INTERIOR ROOM LAMP CIRCUIT
1. Disconnect BCM connector and interior room lamp connector.
2. Check continuity between BCM harne

Page 3735 of 4449

INFINITI FX35 2004  Service Manual LT-180
INTERIOR ROOM LAMP
Revision: 2004 November 2004 FX35/FX45
Personal Lamp Control Does Not OperateAKS007FG
1. CHECK REAR DOOR SWITCH
Select “BCM” on CONSULT-II. With “INT LAMP” data monit