1F – 484IENGINE CONTROLS
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0420
CATALYST OXYGEN SENSOR LOW EFFICIENCY
Circuit Description
In order to control exhaust emissions of Hydrocarbons
(HC), Carbon Monoxide (CO) and Nitrogen Oxide (NOx),
a Three–Way Catalytic Converter (TWC) is used. The cat-
alyst within the converter promotes a chemical reaction
which oxidizes the HC and CO present in the exhaust gas,
converting them into harmless water vapor and carbon
dioxide, it also reduces NOx, converting it into nitrogen.
The catalytic converter also has the ability to store oxygen.
The Engine Control Module (ECM) has the capability to
monitor this process using a Heated
Rear Heated Oxygen Sensor (HO2S2) located in the ex-
haust stream past the TWC. The HO2S2 produces an out-
put signal which indicates the oxygen storage capacity of
the catalyst; this in turn indicates the catalyst’s ability to
convert exhaust emissions effectively. The ECM monitors
the catalyst efficiency by first allowing the catalyst to heat
up, waiting for a stabilization period while the engine is id-
ling, and then adding and removing fuel while monitoring
the reaction of the HO2S2. When the catalyst is function-
ing properly, the HO2S2 response to the extra fuel is slow
compared to the Front Heated Oxygen Sensor (HO2S1).
When the HO2S2 response is close to that of the HO2S1,
the Oxygen storage capability or efficiency of the catalyst
is considered to be bad, and the Malfunction Indicator
Lamp (MIL) will illuminate.
Conditions for Setting the DTC
S Oxygen storage capacity index time is less than 0.3
seconds.
S Before idle test, the vehicle needs to be driven for
at least:
S 15 seconds at airflow is greater than 9.2 g/sec.
for manual transaxle.
S 11 seconds at airflow is greater than 12 g/sec
for automatic transaxle.
S Oxygen Sensor Capacity test condition:
S Closed loop stoichiometry.
S Purge concentration learned.
S Engine is running more than 330 seconds.
S Airflow is between 2.5 and 7.25 g/sec.
S Throttle Position (TP) sensor is less than 1.5%.
S Intake Air Temperature (IAT) is between –7°C
(19.4°F) and 105°C (221°F).
S Barometric pressure (BARO) is greater than 72 kPa
(10.4 psi).
S Catalyst temperature is between 500°C (932°F)
and 850°C (1562°F) for automatic transaxle.
S Catalyst temperature is between 450°C (842°F)
and 850°C (1562°F) for automatic transaxle.
S Closed Loop integrator change is less than 0.03.
S Idle time is less than 1 minute.
S Vehicle speed is less than 3 km/h (1.9 mph).S Block Learn Mode is learned.
S Above condition is stabilized for 5 seconds.
Note : Test is aborted for this idle if:
S Change in engine speed is greater than 80 rpm.
S A/C status changed.
S Cooling fan status changed.
S Insufficient air/fuel shift.
S DTC(s) P0106, P0107, P0108, P0117, P0118,
P0122, P0123, P0131, P0132, P0133, P1133,
P0134, P0135, P0137, P0138, P0140, P0141,
P1167, P1171, P0171, P0172, P0201, P0202,
P0203, P0204, P0300, P0336, P0337, P0341,
P0342, P0351, P0352, P0402, P0404, P1404,
P0405, P0406, P0443, P0502, P0506, P0507, and
P0562 are not set.
Action Taken When the DTC Sets
S The Malfunction Indicator Lamp (MIL) will illumi-
nate.
S The ECM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Freeze Frame and Failure Records
buffers.
S A history DTC is stored.
Conditions for Clearing the MIL/DTC
S The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
S A history DTC will clear after 40 consecutive warm–
up cycles without a fault.
S DTC(s) can be cleared by using the scan tool.
S Disconnecting the ECM battery feed for more than
10 seconds.
Diagnostic Aids
The catalyst test may abort due to a change in the engine
load. Do not change the engine load (i.e. A/C, coolant fan,
heater motor) while a catalyst test is in progress.
An intermittent problem may be caused by a poor connec-
tion, rubbed–through wire insulation, or a wire that is bro-
ken inside the insulation.
Any circuitry, that is suspected as causing the intermittent
complaint, should be thoroughly checked for the following
conditions:
S Backed–out terminals
S Improper mating
S Broken locks
S Improperly formed
S Damaged terminals
S Poor terminal–to–wire connection
Test Description
Number(s) below refer to the step number(s) on the Diag-
nostic Table.
1F – 490IENGINE CONTROLS
DAEWOO V–121 BL4
DTC P0461 – Fuel Level Stuck
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Is the system check complete?–Go to Step 2Go to
”On–Board
Diagnostic Sys-
tem Check”
21. Install a scan tool to the Data Link Connector
(DLC).
2. Start the engine and operate the vehicle over
the specified mileage.
Is any of the Diagnostic trouble Codes (DTCs)
P0462, P0463 or P0502 set?250 km
(155 mile)Go to Applica-
ble DTC tableGo to Step 3
31. Turn the ignition OFF.
2. Disconnect the fuel pump connector.
3. Turn the ignition ON.
4. Using a voltmeter, measure the fuel level signal
voltage at the fuel level sensor connector ter-
minal 1.
Is the voltage within the specified value?4–5 voltsGo to Step 4Go to Step 5
41. Disconnect the Engine Control Module (ECM).
2. Check the fuel level sensor ground circuit for
an open between terminal 6 of the fuel sensor
connector and terminal K34 of the ECM and
repair as needed.
Is the repair complete?–Go to Step 10Go to Step 6
5Using a voltmeter, measure the voltage at the ECM
connector terminal K34 by back–probing the ECM
connector.
Is the voltage within the specified value?4–5 VGo to Step 8Go to Step 9
61. Remove the fuel pump from the fuel tank.
2. Reconnect the fuel pump connector.
3. Turn the ignition ON.
4. Monitor the fuel level sensor parameter on the
scan tool while moving the fuel sensor float
from empty position to full position.
5. Repeat procedure 4 several times.
Does the fuel level sensor vale on the scan tool in-
crease and then decrease steadily when the float is
moved?–Go to
”Diagnostic
Aids”Go to Step 7
71. Turn the ignition OFF.
2. Replace the fuel pump assembly.–Go to Step 10–
81. Turn the ignition OFF.
2. Disconnect the ECM connector.
3. Check the fuel level signal circuit fir an open or
short to ground between terminal K51 and fuel
pump harness connector terminal 1 and repair
as needed.
Is the repair complete?–Go to Step 10–
91. Turn the ignition OFF.
2. Replace the ECM.
Is the repair complete?–Go to Step 10–
ENGINE CONTROLS 1F – 493
DAEWOO V–121 BL4
DTC P0462 – Fuel Level Low Voltage
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Was the check performed?–Go to Step 2Go to
”On–Board
Diagnostic Sys-
tem Check”
21. Install a scan tool to the Data Link Connector
(DLC).
2. Start the engine and operate the vehicle within
Failure Record condition as noted.
Is Diagnostic trouble Codes (DTCs) P0462 set?–Go to Step 3Go to
”Diagnostic
Aids”
31. Turn the ignition OFF.
2. Disconnect the fuel pump connector.
3. Turn the ignition ON.
4. Using a voltmeter, measure the fuel level signal
voltage at the fuel level sensor connector ter-
minal 1.
Is the voltage within the specified value?0.4 – 4.5 VGo to Step 4Go to Step 6
4Check for a proper ground connection at the fuel
tank and repair as needed.
Is the repair complete?–Go to Step 11Go to Step 5
51. Remove the fuel pump from the fuel tank.
2. Reconnect the fuel pump connector.
3. Turn the ignition ON.
4. Monitor the fuel level sensor parameter on the
scan tool while moving the fuel sensor float
from empty position to full position.
5. Repeat procedure 4 several times.
Does the fuel level sensor vale on the scan tool in-
crease and then decrease steadily when the float is
moved?–Go to
”Diagnostic
Aids”Go to Step 8
6Check for an open or short to ground in the fuel level
sensor circuit and repair as needed.
Is the repair necessary?–Go to Step 11Go to Step 9
7Repair the open or short to ground in the fuel level
sensor circuit between the fuel level sensor harness
connector and fuel level sensor.
Is the repair complete?–Go to Step 11–
81. Turn the ignition OFF.
2. Replace the fuel pump assembly.
Is the repair complete?–Go to Step 11–
91. Turn the ignition OFF.
2. Connect the fuel pump connector.
3. Disconnect the engine Control Module (ECM)
connector.
4. Turn the ignition ON.
5. Using a digital voltmeter, measure the voltage
in the signal circuit at terminal K51.
Is the voltage within the specified value?4–5 VGo to Step 10Go to
Section 9E, In-
strumentation/
Driver Informa-
tion
10S Turn the ignition OFF.
S Replace the ECM.
Is the repair complete?–Go to Step 11–
1F – 496IENGINE CONTROLS
DAEWOO V–121 BL4
DTC P0463 – Fuel Level High Voltage
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Was the check performed?–Go to Step 2Go to
”On–Board
Diagnostic Sys-
tem Check”
21. Install a scan tool to the Data Link Connector
(DLC).
2. Start the engine and operate the vehicle within
Failure Record condition as noted.
Is Diagnostic trouble Codes (DTCs) P0463 set?–Go to Step 3Go to
”Diagnostic
Aids”
31. Turn the ignition OFF.
2. Disconnect the fuel pump connector.
3. Turn the ignition ON.
4. Using a voltmeter, measure the fuel level signal
voltage at the fuel level sensor connector ter-
minal 1.
Is the voltage within the specified value?0.4 – 4.5 VGo to Step 4Go to Step 6
4Check for a proper ground connection at the fuel
tank and repair as needed.
Is the repair necessary?–Go to Step 11Go to Step 5
51. Remove the fuel pump from the fuel tank.
2. Reconnect the fuel pump connector.
3. Turn the ignition ON.
4. Monitor the fuel level sensor parameter on the
scan tool while moving the fuel sensor float
from empty position to full position.
5. Repeat procedure 4 several times.
Does the fuel level sensor vale on the scan tool in-
crease and then decrease steadily when the float is
moved?–Go to
”Diagnostic
Aids”Go to Step 8
6Check for short to voltage in the fuel level sensor cir-
cuit and repair as needed.
Is the repair necessary?–Go to Step 7Go to Step 9
7Repair the short to voltage in the fuel level sensor cir-
cuit between the fuel level sensor harness connector
and fuel level sensor.
Is the repair necessary?–Go to Step 11–
8S Turn the ignition OFF.
S Replace the fuel pump assembly.
Is the repair complete? –Go to Step 11–
91. Turn the ignition OFF.
2. Connect the fuel pump connector.
3. Disconnect the engine Control Module (ECM )
connector.
4. Turn the ignition ON.
5. Using a digital voltmeter, measure the voltage
in the signal circuit at terminal K51.
Is the voltage within the specified value?0.4 – 4.5 VGo to Step 10Go to
Section 9E, In-
strumentation/
Driver Informa-
tion
10S Turn the ignition OFF.
S Replace the ECM.
Is the repair complete?–Go to Step 11–
ENGINE CONTROLS 1F – 499
DAEWOO V–121 BL4
S The MIL will turn off after four consecutive ignition
cycles in which the diagnostic runs without a fault.
S A history DTC will clear after 40 consecutive warm–
up cycles without a fault.
S DTC(s) can be cleared by using the scan tool.
S Disconnecting the ECM battery feed for more than
10 seconds.
Diagnostic Aids
An intermittent problem may be caused by a poor connec-
tion, rubbed–through wire insulation, or a wire that is bro-
ken inside the insulation.
VSS signal circuit should be thoroughly checked for the
following conditions:
S Backed–out terminals
S Improper mating
S Broken locks
S Improperly formed
S Damaged terminals
S Poor terminal–to–wire connection
S Physical damage to the wiring harness
Ensure the VSS is correctly tightened with proper torque
to the transmission housing.
Refer to ”Intermittents”in this section.
Test Description
Number(s) below refer to the step number(s) on the Diag-
nostic Table.
1. The On–Board Diagnostic (EOBD) System Check
prompts the technician to complete some basic
checks and store the freeze frame and failure re-cords data on the scan tool if applicable. This
creates an electronic copy of the data taken when
the malfunction occurred. The information is then
stored on the scan tool for later reference.
2. The permanent magnet generator only produces a
signal if the drive wheels are turning greater than 5
mph (8 km/h). This step determines if DTC P0502
is the result of a hard failure or an intermittent con-
dition.
3. Proper engine loads cannot be achieved in a shop
environment to properly run the vehicle within the
Freeze Frame Data conditions. It will be necessary
to drive the vehicle on the road to obtain the proper
engine loads.
4. This step verifies that the ECM is receiving a signal
from the vehicle speed sensor.
5. Refer to service bulletin information for the latest
calibration update.
6. Refer to the latest Techline information for program-
ming procedures.
8. A resistance reading that is higher than the speci-
fied value indicates that the VSS circuitry is open.
10. If the displayed resistance is less than the 1300
ohms, the VSS high and low circuits are shorted
together.
11. This checks the resistance of the VSS if no opens
or shorts were found on the VSS high and low cir-
cuits.
13. The replacement ECM must be reprogrammed.
Refer to the latest Techline procedure for ECM re-
programming.
DTC P0502 – Vehicle Speed Sensor No Signal (Engine Side)
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Was the check performed?–Go to Step 2Go to
”On–Board
Diagnostic Sys-
tem Check”
2Notice : Running the vehicle in gear with the wheels
hanging down at full travel will damage the drive
axles.
1. Install a scan tool to the Data Link Connector
(DLC).
2. Raise the drive wheels.
3. Support the lower control arms so that the
drive axles are in a horizontal (straight) posi-
tion.
4. Start the engine and allow to idle in gear.
Does the scan tool display vehicle speed above the
specific value?0 mphGo to Step 3Go to Step 4
1F – 500IENGINE CONTROLS
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
31. Turn the ignition ON.
2. Review the Freeze Frame data and note the
parameters.
3. Operate the vehicle within the Freeze Frame
conditions and Conditions for Setting this DTC.
Does the scan tool display vehicle speed above the
specific value?0 mphGo to Step 12Go to Step 4
41. Turn the ignition OFF.
2. Disconnect the Vehicle Speed Sensor (VSS)
connector.
3. Turn the ignition ON.
4. Using a voltmeter connected to ground, mea-
sure the voltage in VSS signal circuit, at termi-
nal B.
Is the voltage near the specified value?10.1 vGo to Step 5Go to Step 7
5Using a voltmeter connected to ground, measure
the voltage at terminal C of the VSS connector.
Is the voltage near the specified value?11–14 VGo to Step 6Go to Step 8
6Using a ohmmeter connected to ground, measure
the voltage at terminal A of the VSS connector.
Is the voltage near the specified value?400 WGo to Step 10Go to Step 9
7Check the VSS signal circuit for an open or short to
ground and repair as needed.
Is the repair complete?–Go to Step 12Go to Step 11
8Check the ignition circuit for an open and repair as
needed.
Is the repair complete?–Go to Step 12–
9Check the VSS ground circuit for an open and repair
as needed.
Is the repair complete?–Go to Step 12–
101. Turn the ignition OFF.
2. Replace the VSS.
Is the repair complete?–Go to Step 12–
111. Turn the ignition OFF.
2. Replace the ECM.
Is the repair complete?–Go to Step 12–
121. Using the scan tool, clear the Diagnostic
Trouble Codes (DTCs).
2. Start the engine and idle at normal operating
temperature.
3. Operate the vehicle within the conditions for
setting this DTC as specified in the supporting
text.
Does the scan tool indicate that this diagnostic has
run and passed?–Go to Step 13Go to Step 2
13Check if any additional DTCs are set.
Are any DTCs displayed that have not been diag-
nosed?–Go to
Applicable DTC
tableSystem OK
ENGINE CONTROLS 1F – 507
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE (DTC) P0532
A/C PRESSURE SENSOR LOW VOLTAGE
Circuit Description
The Air Conditioning (A/C) system uses an A/C refrigerant
pressure sensor mounted in the high pressure side of the
A/C refrigerant system to monitor A/C refrigerant pres-
sure. The Engine Control Module (ECM) uses this infor-
mation to turn ON the engine coolant fans when the A/C
refrigerant pressure is high and to keep the compressor
disengaged when A/C refrigerant pressure is excessively
high or low.
The Air Conditioning Pressure (ACP) sensor operates like
other 3–wire sensors. The ECM applies a 5.0 volt refer-
ence and a sensor ground to the sensor. Changes in the
A/C refrigerant pressure will cause the ACP sensor input
to the ECM to vary. The ECM monitors the ACP sensor
signal circuit and can determine when the signal is outside
of the possible range of the sensor. When the signal is out
of range for a prolonged period of time, the ECM will not
allow the A/C compressor clutch to engage. This is done
to protect the compressor.
Conditions for Setting the DTC
S A/C pressure is less than 1 % of the sensor reading
scale.
S Engine is running.
Action Taken When the DTC Sets
S The Malfunction Indicator Lamp (MIL) will not illumi-
nate.S The ECM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffers.
S A history DTC is stored.
S The A/C compressor operation will be disabled
while the low voltage indication exists.
Conditions for Clearing the MIL/DTC
S A history DTC will clear after 40 consecutive warm–
up cycles without a fault.
S DTC(s) can be cleared by using the scan tool.
S Disconnecting the ECM battery feed for more than
10 seconds.
Diagnostic Aids
Inspect harness connectors for backed–out terminals, im-
proper mating, broken locks, improperly formed or dam-
aged terminals, and poor terminal–to–wire connection at
the ECM.
Inspect the wiring harness for damage. If the harness ap-
pears to be OK, observe the A/C pressure display on the
scan tool while moving the connectors and wiring har-
nesses related to the A/C Pressure sensor. A change in
the A/C pressure display will indicate the location of the
fault.
If DTC P0532 cannot be duplicated, reviewing the Fail Re-
cords vehicle mileage since the diagnostic test last failed
may help determine how often the condition that caused
the DTC to set occurs. This may assist in diagnosing the
condition.
1F – 508IENGINE CONTROLS
DAEWOO V–121 BL4
DTC P0532 – A/C Pressure Sensor Low Voltage
StepActionValue(s)YesNo
1Perform an On–Board Diagnostic (EOBD) System
Check.
Was the check performed? –Go to Step 2Go to
”On–Board
Diagnostic Sys-
tem Check”
21. Install a scan tool to the Data Link Connector
(DLC).
2. Idle the engine.
Does the scan tool display Air Conditioning Pressure
(ACP) sensor voltage below the specified value?0.06 VGo to Step 3Go to Step 4
31. Turn the ignition OFF.
2. Disconnect the ACP sensor connector.
3. Jumper the ACP signal circuit, terminal 2 to the
5 volt reference circuit, terminal 1.
4. Turn the ignition switch on.
Does the ACP voltage read more than the specified
value?4.9 VGo to Step 5Go to Step 6
41. Turn the ignition ON, with the engine OFF.
2. Operate the vehicle within the Failure Record
conditions and Conditions For Setting the DTC
as noted.
Does the scan tool display ACP voltage below the
specified value?0.06 VGo to Step 3Go to
”Diagnostic
Aids”
5Inspect the ACP sensor harness connector termi-
nals for the following conditions:
S Poor connections
S Proper contact tension
S Poor terminal–to–wire connection
Is a problem found?–Go to Step 8Go to Step 9
61. Turn the ignition OFF.
2. Remove the jumper wire.
3. Probe the ACP sensor signal circuit terminal 2
with a test light to B+.
4. Turn the ignition ON.
Does the scan tool read over the specified value?4 VGo to Step 7Go to Step 11
7Check the ACP sensor 5 volt reference circuit for an
open or short to ground and repair as needed.
Is the repair complete?–Go to Step 13Go to Step 10
8Repair the connection terminals as necessary.
Is the repair complete?–Go to Step 13–
91. Turn the ignition OFF.
2. Replace the ACP sensor.
Is the repair complete?–Go to Step 13–
101. Turn the ignition OFF.
2. Replace the engine control module (ECM).
Is the repair complete?–Go to Step 13–