2003 NISSAN TEANA Power

[x] Cancel search: Power

Page 422 of 3502

NISSAN TEANA 2003  Service Manual ATC-44
TROUBLE DIAGNOSIS
 
Auto Amp. Terminals and Reference ValueBJS000FW
Measure voltage between each terminal and ground by referring ter-
minals and reference value for unified meter and A/C amp.

Page 423 of 3502

NISSAN TEANA 2003  Service Manual TROUBLE DIAGNOSIS
ATC-45
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
46 W/L Power supply from IGN 2 ON — Battery voltage
47 L/RBlower fan motor feedback 
signalON Fan speed: 1st speed Approx. 8
49 B/Y Sensor grou

Page 433 of 3502

NISSAN TEANA 2003  Service Manual TROUBLE DIAGNOSIS
ATC-55
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
CHECKING TEMPERATURE INCREASE
1. Press temperature control switch (UP, driver side) until 32°C is displayed.
2. Check for hot air at discharge a

Page 434 of 3502

NISSAN TEANA 2003  Service Manual ATC-56
TROUBLE DIAGNOSIS
 
Power Supply and Ground Circuit for Auto Amp.BJS000FZ
SYMPTOM: A/C system does not come on.
INSPECTION FLOW
*1ATC-57, "DIAGNOSIS PROCE-
DURE FOR A/C SYSTEM"
*2ATC-54, "Opera

Page 436 of 3502

NISSAN TEANA 2003  Service Manual ATC-58
TROUBLE DIAGNOSIS
 
1. CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check voltage between unified meter and A/C amp. harness

Page 437 of 3502

NISSAN TEANA 2003  Service Manual TROUBLE DIAGNOSIS
ATC-59
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
LAN System CircuitBJS000G0
SYMPTOM: Mode door motor, intake door motor and/or air mix door motor(s) does not operate normally.
DIAGNOSIS PROCEDUR

Page 438 of 3502

NISSAN TEANA 2003  Service Manual ATC-60
TROUBLE DIAGNOSIS
 
3. CHECK POWER SUPPLY FOR EACH DOOR MOTOR
Check voltage between each door motor harness connector M252,
M253, M254 and M255 terminal 1 and ground.
OK or NG
OK >> GO TO 4.
NG

Page 453 of 3502

NISSAN TEANA 2003  Service Manual TROUBLE DIAGNOSIS
ATC-75
C
D
E
F
G
H
I
K
L
MA
B
AT C
 
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor ha