Page 760 of 2395

5 CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªSELF-LEARNING CONTº in ªWORK SUPPORTº mode with CONSULT-II.
3. Clear the self-learning control coefficient by touching ªCLEARº.
SEF968Y
4. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch ªOFFº.
3. Disconnect mass air flow sensor harness connector, and restart and run engine for at least 5 seconds at idle speed.
4. Stop engine and reconnect mass air flow sensor harness connector.
5. Make sure 1st trip DTC P0100 is displayed.
6. Erase the 1st trip DTC memory. Refer to ªHOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMATIONº,
EC-72.
7. Make sure DTC P0000 is displayed.
8. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected?
Is it difficult to start engine?
YesorNo
Ye s©Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to EC-294,
302.
No©GO TO 6.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-225
Page 761 of 2395
6 CHECK HO2S1 (FRONT) HARNESS PROTECTOR COLOR
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector.
SEF505Y
3. Disconnect corresponding heated oxygen sensor 1 (front) harness connector.
SEF965Y
SEF966Y
©GO TO 7.
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-226
Page 762 of 2395

7 CHECK HO2S1 (FRONT) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and front HO2S terminal as follows.
Refer to Wiring Diagram.
MTBL0473
Continuity should exist.
3. Check harness continuity between ECM terminal or FRONT HO2S terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0474
Continuity should not exist.
4. Also check harness for short to power.
OK or NG
OK©GO TO 8.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
8 CHECK HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between HO2S1 (front) terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-227
Page 763 of 2395
9 CHECK MASS AIR FLOW SENSOR
1. Reconnect harness connectors disconnected.
2. Start engine and warm it up to normal operating temperature.
3. Check voltage between ECM terminal 61 (Mass air flow sensor signal) and ground.
SEF298X
4. If the voltage is out of specification, disconnect mass air flow sensor harness connector and connect it again.
Then repeat above check.
OK or NG
OK©GO TO 10.
NG©Replace mass air flow sensor.
10 CHECK PCV VALVE
1. Install all removed parts.
2. Start engine and let it idle.
3. Remove PCV valve ventilation hose from PCV valve.
4. Make sure that a hissing noise will be heard as air passes through it and a strong vacuum should be felt immediately
when a finger is placed over valve inlet.
SEC137A
OK or NG
OK (With CONSULT-II)©GO TO 11.
OK (Without CONSULT-
II)©GO TO 12.
NG©Replace PCV valve.
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-228
Page 764 of 2395

11 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 14.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-229
Page 765 of 2395
12 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 63 (HO2S1 bank 1 right signal) or 62 (HO2S1 bank 2 left signal) and
engine ground.
3. Check the following with engine speed held at 2,000 rpm constant under no load.
SEF967XA
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 14.
NG©GO TO 13.
13 REPLACE HEATED OXYGEN SENSOR 1 (FRONT)
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
©Replace malfunctioning heated oxygen sensor 1 (front).
14 CHECK INTERMITTENT INCIDENT
Refer to ªTROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTº, EC-140.
©INSPECTION END
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-230
Page 771 of 2395
Diagnostic ProcedureNBEC0122
1 INSPECTION START
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
3. Disconnect corresponding heated oxygen sensor 1 (front) harness connector.
SEF965Y
SEF966Y
©GO TO 2.
2 RETIGHTEN HEATED OXYGEN SENSOR 1 (FRONT)
Loosen and retighten corresponding heated oxygen sensor 1 (front).
Tightening torque:
40 - 60 N´m (4.1 - 6.1 kg-m, 30 - 44 ft-lb)
©GO TO 3.
DTC P0134, P0154 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Diagnostic Procedure
EC-236
Page 775 of 2395

DescriptionNBEC0123SYSTEM DESCRIPTIONNBEC0123S01
Sensor Input Signal to ECMECM func-
tionActuator
Crankshaft position sensor (POS)
Engine speedHeated
oxygen
sensor 1
heater
(front) con-
trolHeated oxygen sensor 1 heat-
ers (front)
Crankshaft position sensor (REF)
The ECM performs ON/OFF control of the heated oxygen sensor 1 heaters (front) corresponding to the engine
speed.
OPERATIONNBEC0123S02
Engine speed rpm Heated oxygen sensor 1 heaters (front)
Above 3,600 OFF
Below 3,600 ON
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0124Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 HTR (B1)
HO2S1 HTR (B2)IEngine speed: Below 3,600 rpm ON
IEngine speed: Above 3,600 rpm OFF
ECM Terminals and Reference ValueNBEC0657Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
3 L/ORHeated oxygen sensor
1 heater (front) (bank
1)[Engine is running]
IEngine speed is below 3,600 rpm.0 - 1.0V
[Engine is running]
IEngine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)
2 R/GHeated oxygen sensor
1 heater (front) (bank
2)[Engine is running]
IEngine speed is below 3,600 rpm.0 - 1.0V
[Engine is running]
IEngine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Description
EC-240