2001 CHRYSLER VOYAGER headlamp

[x] Cancel search: headlamp

Page 624 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
PANEL DIMMING OUTPUT SHORT
POSSIBLE CAUSES
INTERMITTENT WIRING AND CONNECTORS
EMIC DIMMING CIRCUIT SHORT TO GROUND
HEADLAMP SWITCH DIMMING CIRCUIT SHORT TO GROUND
HVAC MODULE DIMMING CIRCUIT

Page 625 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition on.
With the DRBIIIt, erase Body Control Module DTCs.
Turn the ignition off to the lock position.
Disconnect the Headlamp Switch harness connector.
Turn t

Page 626 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
7 Turn the ignition on.
With the DRBIIIt, erase Body Control Module DTCs.
Turn the ignition off to the lock position.
Disconnect the HVAC Module harness connector.
Turn the i

Page 629 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
REAR FOG INDICATOR OUTPUT OPEN
POSSIBLE CAUSES
INTERMITTENT WIRING AND CONNECTORS
REAR FOG LAMP INDICATOR CIRCUIT OPEN
REAR FOG LAMP INDICATOR GROUND CIRCUIT OPEN
REAR FOG LAMP INDICATOR CIRC

Page 630 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off to the lock position.
Disconnect the Body Control Module harness connector.
Disconnect the Headlamp Switch harness connector.
Note: Check connectors -

Page 631 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
REAR FOG INDICATOR OUTPUT SHORT
POSSIBLE CAUSES
INTERMITTENT WIRING AND CONNECTORS
REAR FOG LAMP INDICATOR CIRCUIT SHORT TO GROUND
HEADLAMP SWITCH
BODY CONTROL MODULE
TEST ACTION APPLICABILIT

Page 663 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
DOME LAMP OUTPUT SHORT
When Monitored and Set Condition:
DOME LAMP OUTPUT SHORT
When Monitored: Anytime the Body Control Module is active.
Set Condition: When output voltage status is LOW.
PO

Page 664 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
DOME SWITCH INPUT OPEN
When Monitored and Set Condition:
DOME SWITCH INPUT OPEN
When Monitored: Dome Lamps Off.
Set Condition: When Voltage is below 4.8 volts for 62.5 msec.
POSSIBLE CAUSES
H