1998 JAGUAR X308 service

[x] Cancel search: service

Page 1333 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test L: P0710 
With EM007 and LS008 disconnected, measure the 
resistance between EM007/054 and LS008/007 1 
Repeat for EM007/055 and LS008/007 2 
Is the resistance < 0.5 OHM? 
Yes GO to K5

Page 1389 of 2490

JAGUAR X308 1998 2.G Workshop Manual Automatic Transmission/Transaxle - 4.0L SC V8 - AJ26 - Transmission 
Description 
Description and Operation 
Transmission Assembly 
This electronically controlled five speed  unit is unique to superch

Page 1404 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test B: P0740, P1744 
With EM062 and EM061 disconnected, measure the voltage 
between EM062/038 and EM061/030. 1 
0V? 
Yes GO to A6  
No  Inspect EM062, EM063, EM044 and EM061 for corrosion,

Page 1405 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test C: P0702, P0753, P0758, P0763 
Connect the scan tool 1 
Have the DTC(s) and freeze  frame data been recorded? 
Yes  GO to B2  
B2: RENEW TORQUE CONVERTER
Renew the torque converter 1 
Ha

Page 1413 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test D: P0702, P0748, P1748 
P0753, P0758, P0763 present? 
Yes  Contact Jaguar Service 
PINPOINT TEST D : P0702, P0748, P1748 
TEST CONDITIONSDETAILS/RESULTS/ACTIONS
D1: RETRIEVE DTCS
• NOT

Page 1419 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test E: P0702 
With EM062 disconnected, measure the resistance 
between the following, noting the relevant DTC  1 
For P0702 or P0748 EM062/38 and EM062/036 2 
For P0702 or P1748 EM062/38 and

Page 1422 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test F: P0715 
With EM062 and GB001 disconnected, measure the 
resistance between GB001/012 and EM062/033 1 
Is the resistance < 0.5 OHM? 
Yes GO to E5  
No  Inspect EM062, EM044 and GB001 fo

Page 1426 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test G: P1601 
 With EM062 and GB001 disconnected, measure the 
resistance between GB001/001 and EM062/035 1 
Is the resistance < 0.5 OHM? 
Yes GO to F6  
No  Inspect EM062, EM044 and GB001 f