1998 JAGUAR X308 service

[x] Cancel search: service

Page 1295 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test D: P0702, P1745, P1746, P1747, P0743, P1748 
Renew the solenoid; refer to 44.15.50. 
C13: INTERNAL TRANSMISSION HARNESS CHECK
 Measure the resistance from transmission internal harness

Page 1306 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test E: P1720 (P0721) 
GO to D13  
No  Renew the pressure regulator; refer to 44.15.51. 
D13: INTERNAL TRANSMISSION HARNESS CHECK
 Measure the resistance from transmission internal harness 
m

Page 1311 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test F: P0715 
 With EM007 and EM046 disconnected, measure the insulation resistance between EM007/016 and EM007/044 1 
Is the resistance > 10 MOHM? 
Yes GO to E8  
No  Inspect harness / conn

Page 1316 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test G: P1722 
 With EM007 and EM046 disconnected, measure the insulation resistance between EM007/014 and EM007/042 1 
Is the resistance > 10 MOHM? 
Yes GO to F8  
No  Inspect harness / conn

Page 1321 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test H: P1726 
Pinpoint test I: P1730, P1734, P1779 
G8: END
Perform appropriate service drive cycle and check for the 
presence of DTC. 1 
Has the fault code cleared? 
Yes STOP 
No  Contact

Page 1330 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test J: P1603, P1605, P1608 
With EM007 and EM046 disconnected, measure the insulation 
resistance between EM007/016 and EM007/044 1 
Repeat for EM007/014 and EM007/042 2 
Is the resistance >

Page 1331 of 2490

JAGUAR X308 1998 2.G Workshop Manual Pinpoint test K: P1789, P1793 
Connect the scan tool 1 
Have the DTC(s) and freeze frame data been recorded? 
Yes  GO to J2  
J2: RENEW TCM
Renew the TCM 1 
Has the TCM been renewed? 
Yes GO to J3  
J

Page 1332 of 2490

JAGUAR X308 1998 2.G Workshop Manual  Is underhood fuse F1 OK? 
Yes GO to K3  
No  Renew the fuse (10A) and te st the system for normal 
operation 
K3: CHECK SWITCHED POWER SUPPLY
With EM007 disconnected measure the voltage between 
EM00