AC2QC−03
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−3
1996 LAND CRUISER (RM451U)
PROBLEM SYMPTOMS TABLE
Use the table below to help you find the cause of the problem.The numbers i\
ndicate the priority of the likely
cause of the problem. Check each part in order. If necessary, replace these parts.
SymptomSuspect AreaSee page
No blower operation
4. HTR Fuse
5. Heater main relay
6. Blower motor
7. Blower resistor
8. Blower speed control switch
9. Wire harness−
AC−64
AC−52
AC−57
AC−69 −
No air temperature control
1. Engine coolant volume
2. A/C control assembly
3. Water valve−
AC−69
AC−49
No compressor operation
1. Refrigerant volume
2. A.C Fuse
3. Magnetic clutch
4. Compressor
5. Pressure switch
6. Heater main relay
7. Blower speed control switch
8. A/C switch
9. A/C amplifier
10.Thermistor
11. Wire harnessAC−5 −
AC−33
AC−33
AC−61
AC−64
AC−69
AC−69
AC−74
AC−60 −
Compressor operates intermitently
1. Refrigerant volume
2. Pressure switch
3. A/C amplifier
4. Thermistor
5. Wire harnessAC−5
AC−61
AC−74
AC−60 −
No cool air comes out
1. Refrigerant volume
2. Refrigerant pressure
3. Drive belt
4. Magnetic clutch
5. Compressor
6. Pressure switch
7. Thermistor
8. A/C switch
9. A/C amplifier
10.A/C control assembly
11. Wire harnessAC−5
AC−5
AC−15
AC−33
AC−33
AC−61
AC−60
AC−69
AC−74
AC−69 −
Cool air comes out only at high engine rpm
1. Refrigerant volume
2. Drive bel
3. Magnetic clutch
4. Compressor
5. Condenser
6. Receiver
7. Expansion valve
8. Evaporator
9. Thermistor
10.A/C amplifier
11. Wire harnessAC−5
AC−15
AC−33
AC−33
AC−42
AC−39
AC−47
AC−45
AC−60
AC−74 −
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
AC−4
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
Insuf
ficient cooling
1. Refrigerant volume
2. Drive belt
3. Magnetic clutch
4. Compressor
5. Condenser
6. Receiver
7. Expansion valve
8. Evaporator
9. Refrigerant line
10.Pressure switch
11. A/C amplifier
12.A/C control assemblyAC−5
AC−15
AC−33
AC−33
AC−42
AC−39
AC−47
AC−45
AC−20
AC−61
AC−74
AC−69
No engine idle up when A/C switch ON
1. A/C amplifier
2. ECM
3. Wire harnessAC−74 −
−
No warm air comes out
1. Engine coolant volume
2. A/C control assembly
3. Water valve
4. Heater radiator−
AC−69
AC−49
AC−46
A/C indicator does not light up when mode lever at DEF. position
1. Defroster mode switch
2. A/C switch
3. Wire harnessAC−69
AC−69 −
Rear heater:
SymptomSuspect AreaSee page
No blower operation
1. RR HTR Fuse
2. Rear heater relay
3. Rear heater switch
4. Rear blower motor
5. Rear blower resistor−
AC−65
AC−77
AC−55
AC−58
No warm air come out1. Engine coolant volume
2. Rear heater radiator−
AC−46
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
N14063
AC2QD−01
I01386
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−5
1996 LAND CRUISER (RM451U)
ON−VEHICLE INSPECTION
1. INSPECT REFRIGERANT VOLUME
Observe the sight glass on the liquid tube.
Test conditions:
Running engine at 1,500 rpm
Blower speed control switch set at ”HI”
A/C switch ON
Temperature control set at ”MAX. COOL”
Fully open doors
ItemSymptomAmount of refrigerantRemedy
1Bubbles present in sight glassInsufficient*
1. Check for gas leakage with gas leak
tester and repair if necessary
2. Add refrigerant until bubbles disappear
2No bubbles present in sight glassNone, sufficient or too muchRefer to items 3 and 4
3No temperature difference between compressor inlet and outletEmpty or nearly empty
1. Check for gas leakage with gas leaktester and repair if necessary
2. Add refrigerant until bubbles disappear
4Temperature between compressor inlet and outlet is noticeably differentCorrect or too muchRefer to items 5 and 6
5Immediately after air conditioning is turnedoff, refrigerant in sight glass stays clearToo much
1. Discharge refrigerant
2. Evacuate air and charge proper amount of purified refrigerant
6When air conditioning is turned off,
refrigerant foams and then stays clearCorrect−
*: Bubbles in the sight glass with ambient temperatures higher
than usual can be considered normal if cooling is sufficient.
2. INSPECT REFRIGERAT PRESSURE WITH MANIFOLD
GAUGE SET
This is a method in which the trouble is located by using a man-
ifold gauge set. Read the manifold gauge pressure when the
these conditions are established:
Test conditions:
Temperature at the air inlet with the switch set at RECIRC
is 30 − 35° C (86 − 95° F)
Engine running at 1,500 rpm
Blower speed control switch set at high
Temperature control set at max. cool
HINT:
It should be noted that the gauge indications may vary slightly
due to ambient temperature conditions.
(1) Normally functioning refrigeration system.
Gauge reading:
Low pressure side:
0.15 − 0.25 MPa (1.5 − 2.5 kgf/cm
2)
High pressure side:
1.37 − 1.57 MPa (14 − 15 kgf/cm
2)
SightGlass
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
I01387
Condition : Periodically cools and then fails to cool
I01388
Condition: Insufficient cooling
AC−6
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
(2) Moisture present in refrigeration system.
Symptom seen in
refrigeration systemProbable causeDiagnosisRemedy
During operation, pressure on low
pressure side sometimes become
a vacuum and sometime normal
Moisture entered in refrigeration
system freezes at expansion valve
orifice and temporarily stops cycle,
but normal state is restored after a
time when the ice melts Drier in oversaturated state
Moisture in refrigeration system
freezes at expansion valve orifice
and blocks circulation of refriger-
ant(1) Replace condenser
(2) Remove moisture in cycle
through repeatedly evacuating air
(3) Charge proper amount of new
refrigerant
(3) Insufficient cooling
Symptom seen in
refrigeration systemProbable causeDiagnosisRemedy
Pressure low on both low and
high pressure sides
Bubbles seen in sight glass con-
tinuously
Insufficient cooling performance
Gas leakage at some place in re-
frigeration system Insufficient refrigerant in system
Refrigerant leaking
(1) Check for gas leakage with gas
leak detector and repair if neces-
sary
(2) Charge proper amount of re-
frigerant
(3) If indicated pressure value is
near 0 when connected to gauge,
create the vacuum after inspecting
and repairing the location of the
leak
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
I01450
Condition: Insufficient cooling
I01393
Condition : Does not cool
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−9
1996 LAND CRUISER (RM451U)
(8) Expansion valve improperly
Symptom seen in
refrigeration systemProbable causeDiagnosisRemedy
Pressure too high on both low
and high pressure sides
Frost or large amount of dew on
piping on low pressure side
Trouble in expansion valve
Excessive refrigerant in low
pressure piping
Expansion valve opened too
wide
Check expansion valve
Replace if defective
(9) Defective compression compressor
Symptom seen in
refrigeration systemProbable causeDiagnosisRemedy
Pressure too high on low and
high pressure sides
Pressure too low on high pres-
sure side
Internal leak in compressor
Compression defective
Valve leaking or broken sliding
parts
Repair or replace compressor
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
AC−10
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
3. INSPECT IDLE−UP SPEED
(a) Warm up engine
(b) Inspect idle −up speed when the these conditions are es-
tablished:
Blower switch HI
Electrical load OFF
A/C switch ON
Put gear shift in neutral
Magnetic clutch conditionIdle speed
Magnetic clutch not engaged650 ± 50 rpm
Magnetic clutch engaged800 ± 50 rpm
If idle speed is not as specified, check the IAC valve and air in-
take system.
4. INSPECT FOR LEAKAGE OF REFRIGERANT
(a) Perform in these conditions:
Stop engine.
Secure good ventilation (If not, the gas leak detec-
tor may react to volatile gases which are not refrig-
erant, such as evaporated gasoline and exhaust
gas.)
Repeat the test 2 or 3 times.
Make sure that there is some refrigerant remaining
in the refrigeration system.
When compressor is OFF: approximately 392 − 588
KPa (4 − 6 kgf/cm
2, 57 − 35 psi)
(b) Bring the gas leak detector close to the drain hose before
performing the test.
HINT:
After the blower motor is stopped, leave the cooling unit
for more than 15 minutes.
Expose the gas leak detector sensor the under the drain
hose.
When bring the gas leak detector close to the drain hose,
make sure that the gas leak detector does not react to the
volatile gases.
If such reaction is unavoidable, the vehicle must be lifted up.
(c) If gas leak is not detected on the drain hose, remove the
power transistor from the cooling unit. Then insert the gas
leak detector sensor into the unit and perform the test.
(d) Disconnect the connector and leave the pressure switch for approximately 20 minutes. Then bring the gas leak de-
tector close to the pressure switch and perform the test.
(e) Bring the gas leak detector close to the refrigerant lines and perform the test.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
N13795
Quick Disconnect
AdapterCharging
Service Valve Hose
AC2QE−01
N13794
Vacuum Pump
Vacuum Pump Adapter
N13791
Low Pressure
Service Valve
Vacuum Pump Adapter
High Pressure
Service Valve Manifold
Gauge
Set
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−11
1996 LAND CRUISER (RM451U)
EVACUATING
1. CONNECT QUICK DISCONNECT ADAPTERS TO
CHARGING HOSES
2. REMOVE CAPS FROM SERVICE VALVES ON RE- FRIGERANT LINES
3. INSTALL MANIFOLD GAUGE SET
(a) Close both hand valves of manifold gauge set.
(b) Connect the quick disconnect adapters to the service valves.
4. EVACUATE AIR FROM REFRIGERATION SYSTEM
(a) Connect the vacuum pump adapter to the vacuum pump.
(b) Connect the center hose of the manifold gauge set to the vacuum pump adapter.
(c) Open both the high and low hand valves and run the vacu-
um pump.
(d) After 10 minutes or more, check that the low pressure
gauge indicates 750 mmHg (30 in.Hg) or more.
HINT:
If the reading is not 750 mmHg (30 in.Hg) or more, close both
hand valves of manifold gauge set and stop the vacuum pump.
Check the system for leaks and repair as necessary.
(e) Close both the high and low hand valves and stop the vac-
uum pump.
(f) Leave the system in this condition for 5 minutes or more and check that there is no gauge indicator.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
AC2QF−01
N13790
Low Pressure
Service ValveHigh Pressure
Service Valve
N13792
Gas Leak Detector
AC−12
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
CHARGING
1. INSTALL CHARGING CYLINDER
HINT:
When handling the charging cylinder, always follow the direc-
tion given in the instruction manual.
(a) Charge the proper amount of refrigerant in charging cylin-
der.
(b) Connect the center hose to the charging cylinder.
CAUTION:
Do not open both high and low hand valves of manifold
gauge set.
(c) Open the valve of charging cylinder.
(d) Press the valve core on the side of manifold gauge and expel the air inside of the center hose.
2. INSPECT REFRIGERATION SYSTEM FOR LEAKS
(a) Open the high pressure hand valve and charge refriger- ant.
(b) When the low pressure gauge indicates 98 kPa (1 kgf/cm
2, 14 psi), close the high pressure hand valve.
(c) Using leak detector, check the system for leakage.
(d) If leak is found, repair the faulty component or connection. Add evacuate air from refrigeration system (Refer to 4).
CAUTION:
Use the refrigerant recovery/ recycling machine to recover
the refrigerant whenever replacing parts.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010