1996 SUBARU LEGACY clutch

[x] Cancel search: clutch

Page 942 of 2890

SUBARU LEGACY 1996  Service Repair Manual G3M0505
7) Coat the seal ring with vaseline, and install it in the seal
ring groove of the shaft.
CAUTION:
Do not expand the seal ring excessively when install-
ing.
ST 899580100 INSTALLER
G3M0913
16.

Page 1264 of 2890

SUBARU LEGACY 1996  Service Repair Manual C: INSTALLATION
1) Install PHV onto side frame.
Tightening torque:
18±5 N⋅m (1.8±0.5 kg-m, 13.0±3.6 ft-lb)
2) Connect brake pipes to PHV.
Tightening torque:
15
+3
�2N⋅m (1.5+0.3
�0.2kg-m, 10.8+

Page 1282 of 2890

SUBARU LEGACY 1996  Service Repair Manual 2. CHECKING THE HYDRAULIC UNIT OPERATION BY
PRESSURE GAUGE
1) Remove the FL and FR pipes from the hydraulic unit.
G4M0460
2) Connect two pressure gauges to the hydraulic unit.
CAUTION:
Pressure gauge

Page 1284 of 2890

SUBARU LEGACY 1996  Service Repair Manual G4M0462
3. CHECKING THE HYDRAULIC UNIT WITH BRAKE
TESTER
1) In the case of AWD vehicles, install a spare fuse with
the FWD connector in the engine compartment to simulate
FWD vehicles.
B4M0082A
2) Con

Page 1285 of 2890

SUBARU LEGACY 1996  Service Repair Manual 7) Read values indicated on the brake tester and check if
the fluctuation of values, when decompressed and
compressed, meet the standard values.
Initial value When decompressed When compressed
Front w

Page 1324 of 2890

SUBARU LEGACY 1996  Service Repair Manual D: ABS SEQUENCE CONTROL
1) Under the ABS sequence control, after the hydraulic
unit solenoid valve is driven, the operation of the hydraulic
unit can be checked by means of the brake tester or pres-
s

Page 1325 of 2890

SUBARU LEGACY 1996  Service Repair Manual B4M0997
5) The message shown in the figure is displayed.
B4M0998
6) The message shown in the figure is displayed as fol-
lows:
(1) When using the brake tester, depress brake pedal
with braking force o

Page 1337 of 2890

SUBARU LEGACY 1996  Service Repair Manual 2. Hill Holder
Trouble and possible cause Corrective action
1. Counterforce of clutch pedal is too strong.
(1) PHV cable is damaged or does not operate properly. Repair or replace.
(2) Lever of PHV is