SUZUKI GRAND VITARA 1987  Service Repair Manual 4. ENGINE OIL AND FILTER CHANGEBefore draining engine oil, check engine for oil
leakage. If any evidence of leakage is found, 
make sure to correct defective part before
proceeding to the following wo

Page 36 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual 3) Check propeller shaft (No. 1, No. 2, No. 3)
flange yoke bolts for tightness, and retighten
them as necessary:
N.mkg-mlb-ftTighteningtorque23-302.3-3.017.0-21.5
42. TRANSMISSION, TRANSFER,
DIFFERENT

Page 37 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual Oil filler andlevel plug
Oil drain plug
18 - 25 N.m(1.8 - 2.5 kg-m)(13.5 - 18.0 lb-ft)
43. LEAF SPRING lNSPECTlON
Check leaf spring for wear, crack and damage.
(Where each end of the shorter leaf cont

Page 40 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual 2-1. ENGINE
Cond it ion
Poor starting
(Hard starting)
Possible cause
Starter will not run
1. Main fuse blown off
2. Contact not closing in main switch, or this
switch open-circuited
3. Run-down batter

Page 41 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual Condition
Poor starting
(Hard starting)
Possible cause
6. Broken valve timing belt
7. Poor valve seating
8. Wrong kind of engine oil
9. Burnt valves
10. Sticky valve stem
Correction
Replace
Repair or

Page 42 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual ConditionPossible causeCorrection
Not enough powerEmission control
1. Malfunctioning EGR valve
Check and replace as
necessary.
Check and replace as
2. Malfunctioning bowl vent solenoid valve.necessary

Page 45 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual 9
Cond it ionPossible causeCorrection
OverheatingAbnormal condition in ignition system
1. Improper ignition timingAdjust
2. Wrong heat value of spark plugsChange heat value
Abnormal condition in fuel

Page 46 of 962

SUZUKI GRAND VITARA 1987  Service Repair Manual ConditionPossible causeCorrection
High fuel consumptionAbnormal condition ignition system
1. Improper ignition timingAdjust
2. Leak or loose connection of high tension cordRepair or replace
3. Defecti