Page 992 of 2389

(d) To release the air, loosen the union bolt of the water out-
let five revolutions.
(e) Slowly fill the system with coolant.
Use a good brand of ethylene±glycol base coolant,
mixed according to the manufacturer's directions.
Capacity (w/ Heater):
M/T 9.5 liters (10.0 US qts, 8.4 Imp. qts)
A/T 9.4 liters (9.9 US qts, 8.3 Imp. qts)
(f) Tighten the union bolt of the water outlet.
Torque: 180 kg±cm (13 ft±Ib, 18 N±m)
(g) Install the radiator cap.
(h) Start the engine and check for leaks.
(i) Recheck the coolant level and refill as necessary.
HINT: When the coolant has been depleted, refill with
coolant and repeat steps (d) to (i). 4. (2VZ±FE)
REPLACE ENGINE COOLANT
(a) Remove the radiator cap.
CAUTION: To avoid the danger of being burned, do not re-
move it while the engine and radiator are still hot as fluid
and steam can be blown out under pressure.
(b) Drain the coolant from the radiator and engine drain cocks.
(Engine drain cocks are at the front center and rear right
of the cylinder block.)
(c) Close the drain cocks.
Torque (Engine drain cock):
300 kg±cm (22 ft±Ib, 29 N±m)
NOTICE:
wDo not use alcohol type coolant.
wThe coolant should be mixed with demineralized
water or distilled water.
Capacity (w/ Heater).
M/T 6.4 liters (6.8 US qts, 5.6 Imp. qts)
A/T (2WD) 6.3 liters (6.7 US qts, 5.5 Imp. qts)
A/T (4WD) 6.8 liters (7.2 US qts, 6.0 Imp. qts)
(e) Install the radiator cap.
(f) Start the engine and check for leaks.
(g) Recheck the coolant level and refill as necessary. (d) Fill the system with coolant.
Use a good brand of ethylene±glycol base coolant, mixed
according to the manufacturer's directions.
Using coolant which includes more than 5O%
ethylene±glycol (but less than 70%) is recommended.
± COOLING SYSTEMCheck and Replacement of Engine CoolantCO±5
Page 993 of 2389
REMOVAL OF WATER PUMP
1. DRAIN ENGINE COOLANT (See page CO±4)
2. DISCONNECT WATER TEMPERATURE SWITCH
CONNECTOR
3. DISCONNECT RADIATOR LOWER HOSE FROM
WATER INLET HOUSING
4. REMOVE TIMING BELT, PULLEYS
(See pages EM±23 to 26)
5. REMOVE WATER PUMP AND WATER PUMP COVER
ASSEMBLY .
(a) Remove the two nuts holding the pump to the water by±
pass pipe.
WATER PUMP (3S±FE)
COMPONENTS
± COOLING SYSTEMWater Pump (3S±FE)CO±6
Page 995 of 2389
(b) Apply a fight coat of engine oil on the 4±ring of the water
by±pass pipe.
(c) Connect the pump cover to the water by±pass pipe. Do
not install the nuts yet.
(d) Install the water pump with the three bolts. Torque the
bolts in the sequence shown.
Torque: 95 kg±cm (82 in.±Ib, 9.3 N±m)
3. INSTALL PULLEYS AND TIMING BELT (See pages
EM±29 to 33)
4. CONNECT RADIATOR LOWER HOSE
5. CONNECT WATER TEMPERATURE SWITCH
CONNECTOR
6. FILL WITH ENGINE COOLANT (See page CO±5) (e) Install the two nuts holding the pump cover to the water
by±pass pipe.
Torque: 95 kg±cm (82 in.±Ib, 9.3 N±m)
± COOLING SYSTEMWater Pump PS±FE)CO±8
Page 996 of 2389
REMOVAL OF WATER PUMP
1. DRAIN ENGINE COOLANT (See page CO±5)
2. DISCONNECT RADIATOR LOWER NOSE FROM
WATER INLET PIPE
3. DISCONNECT TIMING BELT FROM WATER PUMP
PULLEY (See pages EM±34 to 39)
4. REMOVE WATER INLET PIPE
(a) Remove the bolt holding the water inlet pipe to the alternator
belt adjusting bar.
(b) Remove the water inlet pipe and 0±ring.
5. REMOVE WATER INLET AND THERMOSTAT
(See steps 4 and 5 on page CO±13)
WATER PUMP(2VZ±FE)
COMPONENTS
± COOLING SYSTEMWater Pump (2VZ±FE)CO±9
Page 998 of 2389
3. INSTALL WATER INLET PIPE
(a) Install a new 0±ring to the water inlet pipe.
(b) Apply soapy water to the O±ring.
(c) Connect the water inlet pipe to the water inlet.
(d) Install the bolt holding the water inlet pipe to the alternator
belt adjusting bar.
Torque: 200 kg±cm (14 ft±Ib, 20 N±m)
4. INSTALL TIMING BELT (See pages EM±42 to 46)
5. CONNECT RADIATOR LOWER HOSE
6. FILL WITH ENGINE COOLANT (See page CO±5)
± COOLING SYSTEMWater Pump (2VZ±FE)CO±11
Page 999 of 2389

THERMOSTAT (3S±FE)
REMOVAL OF THERMOSTAT
1. DRAIN ENGINE COOLANT (See page CO±4)
2. DISCONNECT WATER TEMPERATURE SWITCH
CONNECTOR
3. DISCONNECT RADIATOR FROM WATER INLET
HOUSING
4. REMOVE WATER INLET HOUSING
Remove the two nuts and water inlet housing from the
waterpump.
5. REMOVE THERMOSTAT AND GASKET
INSPECTION OF THERMOSTAT
INSPECT THERMOSTAT
HINT: The thermostat is numbered with the valve opening
temperature.
(a) Immerse the thermostat in water and gradually heat the wa-
ter.
(b) Check the valve opening temperature.
Valve opening temperature:
80 ± 845C (176 ± 1835F)
If the valve opening temperature is not as specified, re-
place the thermostat.
(e) Check the valve lift.
Valve lift:
8 mm (0.31 in.) or more at 95°C (203°F)
If the valve lift is less than specification, replace the
thermostat.
INSTALLATION OF THERMOSTAT
1. PLACE THERMOSTAT IN WATER INLET HOUSING
(a) Install a new gasket to the thermostat.
(b) Align the jiggle valve of the thermostat with protrusion of the
water inlet housing and, insert the thermostat in the water
inlet housing.
2. INSTALL WATER INLET HOUSING AND THERMOSTAT
ASSEMBLY
Install the water inlet housing and thermostat assembly with
the two nuts.
Torque: 90 kg±cm (78 in.±Ib, 8.8 N±m)
3. CONNECT RADIATOR LOWER HOSE
4. CONNECT WATER TEMPERATURE SWITCH
CONNECTOR
5. FILL WITH ENGINE COOLANT (See page CO±5)
6. START ENGINE AND CHECK FOR LEAKS
± COOLING SYSTEMThermostat (3S±FE)CO±12
Page 1000 of 2389
(b) Check the valve opening temperature
Valve opening temperature:
80 ± 845C (176 ± 1835F)
If the valve opening temperature is not as specified, re-
place the thermostat.
(c) Check the valve lift.
Valve lift:
8.5 mm (0.335 in.) or more at 95
°C (203°F)
If the valve lift is less than specification, replace the ther-
mostat.
(d) Check that the valve spring is tight when the thermostat
is fully closed.
THERMOSTAT (2VZ±FE)
REMOVAL OF THERMOSTAT
1. DRAIN ENGINE COOLANT (See page CO±5)
2. REMOVE WATER INLET PIPE
(See steps 2 and 4 on page CO±9)
3. DISCONNECT WATER TEMPERATURE SENSOR
CONNECTOR
INSPECTION OF THERMOSTAT
INSPECT THERMOSTAT
HINT: The thermostat is numbered with the valve opening
temperature.
(a) Immerse the thermostat in water and gradually heat the wa-
ter. 4. REMOVE WATER INLET
Remove the three nuts and water inlet from the water
pump.
5. REMOVE THERMOSTAT AND GASKET
± COOLING SYSTEMThermostat (2VZ±FE)CO±13
Page 1001 of 2389
INSTALLATION OF THERMOSTAT
1. PLACE THERMOSTAT IN WATER PUMP
(a) install a new gasket to the thermostat.
(b) Align the jiggle valve of the thermostat with stud bolt
(A), and insert the thermostat in the water pump.
3. CONNECT WATER TEMPERATURE SENSOR
CONNECTOR
4. INSTALL WATER INLET PIPE
(See steps 3 and 5 on page CO±11)
5. FILL WITH ENGINE COOLANT (See page CO±5)
6. START ENGINE AND CHECK FOR LEAKS2. INSTALL WATER INLET
Install the water inlet with the three nuts.
Torque: 200 kg±cm (14 ft±Ib, 20 N±m)
± COOLING SYSTEMThermostat (2VZ±FE)CO±14