DTC Description Possible Causes Action B11F0-11
Air Intake Damper
Position Sensor -
Circuit short to
ground
RECIRC servo motor air
intake feedback and 5
volt supply circuits -
short to ground
Refer to the electrical circuit diagrams and check RECIRC
servo motor air intake feedback and 5 volt supply circuits
for short to ground B11F0-15
Air Intake Damper
Position Sensor -
Circuit short to
battery or open
RECIRC servo motor air
intake feedback and
ground circuits - short
to power, open circuit
Carry out any pinpoint tests associated with this DTC using the manufacturer approved diagnostic system. Refer to the electrical circuit diagrams and check RECIRC servo motor air intake feedback and ground circuits for short to power, open circuit B11F8-00
Left Outer Vent -
No sub type
information
Left outer IP vent
actuator internal or
external fault
Carry out any pinpoint tests associated with this DTC using
the manufacturer approved diagnostic system B11F8-49
Left Outer Vent -
Internal electronic
failure
Left outer IP vent
actuator internal
electronic failure
Suspect the left outer IP vent actuator. Check and install a
new actuator as required, refer to the new
module/component installation note at the top of the DTC
Index B11F9-00
Left Inner Vent -
No sub type
information
Left inner IP vent
actuator internal or
external fault
Carry out any pinpoint tests associated with this DTC using
the manufacturer approved diagnostic system B11F9-49
Left Inner Vent -
Internal electronic
failure
Left inner IP vent
actuator internal
electronic failure
Suspect the left inner IP vent actuator. Check and install a
new actuator as required, refer to the new
module/component installation note at the top of the DTC
Index B11FA-00
Right Inner Vent -
No sub type
information
Right inner IP vent
actuator internal or
external fault
Carry out any pinpoint tests associated with this DTC using
the manufacturer approved diagnostic system B11FA-49
Right Inner Vent -
Internal electronic
failure
Right inner IP vent
actuator internal
electronic failure
Suspect the right inner IP vent actuator. Check and install a
new actuator as required, refer to the new
module/component installation note at the top of the DTC
Index B11FB-00
Right Outer Vent -
No sub type
information
Right outer IP vent
actuator internal or
external fault
Carry out any pinpoint tests associated with this DTC using
the manufacturer approved diagnostic system B11FB-49
Right Outer Vent -
Internal electronic
failure
Right outer IP vent
actuator internal
electronic failure
Suspect the right outer IP vent actuator. Check and install a
new actuator as required, refer to the new
module/component installation note at the top of the DTC
Index B11FF-84
A/C Refrigerant
Pressure - Signal
below allowable
range
Signal below allowable
range. A/C System
Refrigerant Pressure
too low
This DTC can be logged by the system due to low ambient
temperature soak (below 3°C) reducing the pressure in the
refrigerant gas system. If the cabin temperature logged
along with the DTC at the time is below 10°C this could
indicate low temperature. If the air conditioning
performance is satisfactory and the in-cabin temperature is
below 10°C then it is likely that the system contains a
suitable amount of gas and the DTC is being recorded as
an effect of the low ambient temperature. If this is not the
case carry out any pinpoint tests associated with this DTC
using the manufacturer approved diagnostic system. Refer
to the electrical circuit diagrams and check air conditioning
pressure sensor circuits for short, open circuit. Check for
correct charge weight B11FF-85
A/C Refrigerant
Pressure - Signal
above allowable
range
Signal above allowable
range. A/C System
Refrigerant pressure
too high
Carry out any pinpoint tests associated with this DTC using
the manufacturer approved diagnostic system. Refer to the
electrical circuit diagrams and check air conditioning
pressure sensor circuits for short, open circuit