DTC P0300, P0301, P0302, P0303, P0304, P0305, P0306 MULTIPLE CYLINDER
MISFIRE, NO. 1 - 6 CYLINDER MISFIRE
EC-309
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
5. Check 1st trip DTC.
6. If 1st trip DTC is detected, go to
EC-309, "
Diagnosis Procedure".
NOTE:
If 1st trip DTC is not detected during above proc edure, performing the following procedure is advised.
a. Turn ignition switch OFF and wait at least 10 seconds.
b. Start engine and drive the vehicle under the similar conditi ons to (1st trip) Freeze Frame Data for a certain
time. Refer to table below.
Hold the accelerator pedal as steady as possible.
The similar conditions to (1st trip) Freeze Frame Data means the vehicle operation that the following condi-
tions should be satisfied at the same time.
The time to driving varies according to the engine speed in the freeze frame data.
Refer to the following table.
WITH GST
Follow the procedure “WITH CONSULT-III” above.
Diagnosis ProcedureINFOID:0000000001326133
1.CHECK FOR INTAKE AIR LEAK AND PCV HOSE
1. Start engine and run it at idle speed.
2. Listen for the sound of the intake air leak.
3. Check PCV hose connection.
OK or NG
OK >> GO TO 2.
NG >> Discover air leak location and repair.
2.CHECK FOR EXHAUST SYSTEM CLOGGING
Stop engine and visually check exhaust tube, three way catalyst and muffler for dents.
OK or NG
OK (With CONSULT-III)>>GO TO 3.
OK (Without CONSULT-III)>>GO TO 4.
NG >> Repair or replace it.
3.PERFORM POWER BALANCE TEST
With CONSULT-III
1. Perform “POWER BALANCE ” in “ACTIVE TEST” mode.
2. Is there any cylinder which does not produce a momentary engine speed drop?
Ye s o r N o
Yes >> GO TO 4.
No >> GO TO 10.
4.CHECK FUNCTION OF FUEL INJECTOR-I
Engine speed Engine speed in the freeze frame data ± 400 rpm
Vehicle speed Vehicle speed in the freeze frame data ± 10 km/h (6 MPH)
Engine coolant temperature (T)
condition When the freeze frame data shows lower than 70
°C (158 °F),
T should be lower than 70 °C (158 °F).
When the freeze frame data shows higher than or equal to 70 °C (158 °F),
T should be higher than or equal to 70 °C (158 °F).
Engine speed Time
Around 1,000 rpm Approximately 10 minutes
Around 2,000 rpm Approximately 5 minutes
More than 3,000 rpm Approximately 3.5 minutes
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
DTC P0327, P0328 KSEC-317
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000001326138
1.CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-I
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check resistance between ECM terminal 15 and ground. Refer to Wiring Diagram. NOTE:
It is necessary to use an ohmmeter which can measure more than 10 M Ω.
OK or NG
OK >> GO TO 5.
NG >> GO TO 2.
2.CHECK KNOCK SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Disconnect knock sensor harness connector.
2. Check harness continuity between ECM terminal 15 and knock sensor terminal 1.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3.DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F20, F252
Harness for open or short between ECM and knock sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK KNOCK SENSOR
Refer to EC-318, "
Component Inspection".
OK or NG
OK >> GO TO 5.
NG >> Replace knock sensor.
5.CHECK GROUND CONNECTIONS
TER- MI-
NAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
15 W Knock sensor [Engine is running]
Idle speedApproximately 2.5V
Resistance: Approximately 532 - 588 k
Ω [at 20 °C (68 °F)]
Continuity should exist.
PBIB1564E
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
DTC P0335 CKP SENSOR (POS)EC-321
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
CAUTION:
Do not use ECM ground terminals wh
en measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground ot her than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnosis ProcedureINFOID:0000000001326146
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground screw on the body. Refer to EC-144, "
Ground Inspection".
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2.CHECK CRANKSHAFT POSITION SENS OR (POS) POWER SUPPLY CIRCUIT
TER-
MI-
NAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
13 Y Crankshaft position sensor
(POS) [Engine is running]
Warm-up condition
Idle speed NOTE:
The pulse cycle changes depending on rpm
at idle Approximately 1.6V
[Engine is running]
Engine speed: 2,000 rpm Approximately 1.4V
111 W / B ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF 0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni- tion switch OFF BATTERY VOLTAGE
(11 - 14V)
11 9
120 R
R/B
Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
PBIB1041E
PBIB1042E
PBIB2625E
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
EC-328
< SERVICE INFORMATION >[VQ35DE]
DTC P0340, P0345
CMP SENSOR (PHASE)
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnosis ProcedureINFOID:0000000001326154
1.CHECK STARTING SYSTEM
Turn ignition switch to START position.
Ye s o r N o
Ye s > > G O T O 2 .
No >> Check starting system. (Refer to SC-8
.)
2.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground screw on the body. Refer to EC-144, "
Ground Inspection".
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
3.CHECK CAMSHAFT POSITION (CMP) SENS OR (PHASE) POWER SUPPLY CIRCUIT
TER-
MI-
NAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
14 BR Camshaft position sensor
(PHASE) (bank 2) [Engine is running]
Warm-up condition
Idle speed
NOTE:
The pulse cycle changes depending on rpm
at idle 1.0 - 4.0V
[Engine is running]
Engine speed: 2,000 rpm 1.0 - 4.0V
11 9
120 R
R/B
Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
PBIB1039E
PBIB1040E
Does the engine turn over?
Does the starter motor operate?
PBIB2625E
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
EC-332
< SERVICE INFORMATION >[VQ35DE]
DTC P0420, P0430 THREE
WAY CATALYST FUNCTION
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
On Board Diagnosis LogicINFOID:0000000001326157
The ECM monitors the switching frequency ratio of air fuel ratio (A/F) sensor 1 and heated oxygen sensor 2.
A three way catalyst 1 with high oxygen storage capacity will indicate a low switching frequency of heated oxy-
gen sensor 2. As oxygen storage capacity decreas es, the heated oxygen sensor 2 switching frequency will
increase.
When the frequency ratio of air fuel ratio (A/F) sens or 1 and heated oxygen sensor 2 approaches a specified
limit value, the three way catalyst 1 malfunction is diagnosed.
DTC Confirmation ProcedureINFOID:0000000001326158
NOTE:
If DTC Confirmation Procedure has been previously conduc ted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-III
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
2. Start engine and warm it up to the normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C (158 °F).
If not, warm up engine and go to next step when “C OOLAN TEMP/S” indication reaches to 70°C (158 °F).
7. Open engine hood.
8. Select “DTC & SRT CONFIRMATION” then “S RT WORK SUPPORT” mode with CONSULT-III.
9. Rev engine up to 2,000 to 3,000 rpm and hold it for 3 consecutive minutes then release the accelerator pedal completely.
If “INCMP” of “CATALYST” changed to “CMPLT”, go to step 12.
10. Wait 5 seconds at idle.
11. Rev engine up to 2,000 to 3,000 rpm and maintain it until “INCMP” of “CATALYST” changes to “CMPLT” (It
will take approximately 5 minutes).
If not “CMPLT”, stop engine and cool it down to less than 70 °C (158 °F) and then retest from step 1.
12. Select “SELF-DIAG RESULTS” mode with CONSULT-III.
13. Confirm that the 1st trip DTC is not detected. If 1st trip DTC is detected, go to EC-333, "
Diagnosis Procedure".
PBIB1923E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420
(Bank 1) Catalyst system efficien-
cy below threshold Three way catalyst 1 does not operate prop-
erly.
Three way catalyst 1 does not have enough oxygen storage capacity. Three way catalyst 1
Exhaust tube
Intake air leaks
Fuel injector
Fuel injector leaks
Spark plug
Improper ignition timing
P0430
0430
(Bank 2)
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
EC-336
< SERVICE INFORMATION >[VQ35DE]
DTC P0441 EVAP CONTROL SYSTEM
DTC P0441 EVAP CONTROL SYSTEM
System DescriptionINFOID:0000000001326161
NOTE:
If DTC P0441 is displayed with other DTC such
as P2122, P2123, P2127, P2128 or P2138, first perform
trouble diagnosis for other DTC.
In this evaporative emission (EVAP) control system, purge flow occurs during non-closed throttle conditions.
Purge volume is related to air intake volume. Under normal purge conditions (non-closed throttle), the EVAP
canister purge volume control solenoid valve is open to admit purge flow. Purge flow exposes the EVAP con-
trol system pressure sensor to intake manifold vacuum.
On Board Diagn osis LogicINFOID:0000000001326162
Under normal conditions (non-closed throttle), sensor output voltage indicates if pressure drop and purge flow
are adequate. If not, a ma lfunction is determined.
DTC Confirmation ProcedureINFOID:0000000001326163
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If DTC Confirmation Procedure has been previously conduc ted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-III
PBIB1026E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0441
0441 EVAP control system in-
correct purge flow EVAP control system does not operate proper-
ly, EVAP control system has a leak between in-
take manifold and EVAP control system
pressure sensor. EVAP canister purge volume control so-
lenoid valve stuck closed
EVAP control system pressure sensor and the circuit
Loose, disconnected or improper con- nection of rubber tube
Blocked rubber tube
Cracked EVAP canister
EVAP canister purge volume control so- lenoid valve circuit
Accelerator pedal position sensor
Blocked purge port
EVAP canister vent control valve
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
DTC P0441 EVAP CONTROL SYSTEMEC-337
< SERVICE INFORMATION > [VQ35DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 70 seconds.
4. Select “PURG FLOW P0441” of “EVAPORATIVE
SYSTEM” in “DTC CONFIRMATION” mode with CON-
SULT-III.
5. Touch “START”.
If “COMPLETED” is displayed, go to step 7.
6. When the following conditions are met, “TESTING ” will be displayed on the CONSULT-III screen. Maintain
the conditions continuously until “TES TING” changes to “COMPLETED”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7. Make sure that “OK” is displayed after touching “S ELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
337, "Diagnosis Procedure".
Overall Function CheckINFOID:0000000001326164
Use this procedure to check the overall monitoring func tion of the EVAP control system purge flow monitoring.
During this check, a 1st trip DTC might not be confirmed.
WITH GST
1. Lift up drive wheels.
2. Start engine (TCS switch or VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM te rminals 32 (EVAP control system
pressure sensor signal) and ground.
6. Check EVAP control system pressure sensor value at idle speed and note it.
7. Establish and maintain the following conditions for at least 1
minute.
8. Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (mea-
sured at step 6) for at least 1 second.
9. If NG, go to EC-337, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001326165
1.CHECK EVAP CANISTER
1. Turn ignition switch OFF.
2. Check EVAP canister for cracks.
OK or NG
OK (With CONSULT-III)>>GO TO 2.
OK (Without CONSULT-III)>>GO TO 3.
NG >> Replace EVAP canister.
2.CHECK PURGE FLOW
Selector lever Suitable position
VHCL SPEED SE 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,000 rpm
B/FUEL SCHDL 1.3 - 9.0 msec
COOLAN TEMP/S 70 - 100 °C (158 - 212 °F)
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Selector lever Any position other than P, N or R
PBIB1109E
3AA93ABC3ACD3AC03ACA3AC03AC63AC53A913A773A893A873A873A8E3A773A983AC73AC93AC03AC3
3A893A873A873A8F3A773A9D3AAF3A8A3A8C3A863A9D3AAF3A8B3A8C
EC-342
< SERVICE INFORMATION >[VQ35DE]
DTC P0442 EVAP CONTROL SYSTEM
If DTC Confirmation Procedure has been previously conduc
ted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is placed
on flat level surface.
Always perform test at a temperature of 0 to 30 °C (32 to 86 °F).
WITH CONSULT-III
1. Turn ignition switch ON.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
4. Make sure that the following conditions are met.
COOLAN TEMP/S: 0 - 70 °C (32 - 158 °F)
INT/A TEMP SE: 0 - 30 °C (32 - 86 °F)
5. Select “EVAP SML LEAK P0442/P1442” of “EV APORATIVE SYSTEM” in “DTC WORK SUPPORT” mode
with CONSULT-III.
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within t he range displayed on the CONSULT-III screen, go to
EC-80, "
Basic Inspection".
6. Make sure that “OK” is displayed. If “NG” is displayed, refer to EC-342, "
Diagnosis Procedure".
NOTE:
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve
properly.
WITH GST
NOTE:
Be sure to read the explanation of EC-55, "
Emission-Related Diagnostic Information" before driving vehicle.
1. Start engine.
2. Drive vehicle according to EC-55, "
Emission-Related Diagnostic Information".
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
5. Select Service $07 with GST.
- If P0442 is displayed on the screen, go to EC-342, "
Diagnosis Procedure".
- If P0441 is displayed on the screen, go to EC-337, "
Diagnosis Procedure" for DTC P0441.
Diagnosis ProcedureINFOID:0000000001326168
1.CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK >> GO TO 2.
NG >> Replace with genuine NISSAN fuel filler cap.
2.CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened proper ly by rotating the cap clockwise.
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
SEF915U