ATC-78
< SERVICE INFORMATION >
TROUBLE DIAGNOSIS
1. Disconnect the defroster door motor harness connector.
2. Check continuity between defroster door motor harness connec-tor M144 (B) terminal 3, 2 and fr ont air control harness connec-
tor M49 (A) terminal 2, 15.
OK or NG
OK >> Replace defroster door motor. Refer to ATC-138,
"Removal and Installation".
NG >> Repair or replace harness as necessary.
10.CHECK PBR FEEDBACK VOLTAGE
1. Reconnect the front air control harness connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 25 and ground while cycling defroster switch on and off.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
11 .CHECK PBR FEEDBACK SIGNAL CIRCUIT FOR SHORT TO GROUND
1. Turn ignition switch OFF.
2. Disconnect front air control harness connector.
3. Check continuity between front air control harness connector M49 terminal 25 and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-123, "Removal
and Installation" .
NG >> Repair or replace harness as necessary.
12.CHECK PBR FEEDBACK CIRCUIT FOR OPEN
1. Turn ignition switch OFF.
2. Disconnect the defroster door motor harness connector and front air control harness connector.
3. Check continuity between defroster door motor harness connec- tor M144 terminal 4 and front air control harness connector M49
terminal 25
OK or NG
OK >> Replace defroster door motor. Refer to ATC-138,
"Removal and Installation".
NG >> Repair or replace harness as necessary.
Front Blower Motor CircuitINFOID:0000000003533256
SYMPTOM:• Blower motor operation is malfunctioning.
INSPECTION FLOW
2 - 3 : Continuity should exist.
15 - 2 : Continuity should exist.
WJIA1777E
Voltage : Approx. 1V - 4.5V
WJIA1786E
Continuity should not exist.
WJIA1787E
Continuity should exist.
WJIA0558E
TROUBLE DIAGNOSISATC-83
< SERVICE INFORMATION >
C
DE
F
G H
I
K L
M A
B
AT C
N
O P
7.CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1. Disconnect front air control connector.
2. Check continuity between front air control harness connector
M49 terminal 13 and variable blower control harness connector
M122 terminal 2.
OK or NG
OK >> GO TO 8.
NG >> Repair harness or connector.
8.CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front blower motor relay harness con- nector M107 terminal 2 and ground.
OK or NG
OK >> GO TO 9.
NG >> Repair harness or connector.
9.CHECK FRONT BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front blower motor relay connector M107 terminal 1 and front air control harness connector M49 ter-
minal 26.
OK or NG
OK >> Replace front air control. Refer to ATC-123, "Removal
and Installation" .
NG >> Repair harness or connector.
10.REPLACE FUSES
1. Replace fuses.
2. Activate the front blower motor.
3. Do fuses blow?
YES or NO
YES >> GO TO 11.
NO >> Inspection End.
11 .CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT 13 - 2 : Continuity should exist.
WJIA1362E
2 - Ground : Battery voltage.
WJIA1363E
1 - 26 : Continuity should exist.
WJIA1364E
ATC-84
< SERVICE INFORMATION >
TROUBLE DIAGNOSIS
1. Turn ignition switch OFF.
2. Disconnect front blower motor connector and variable blowercontrol connector.
3. Check continuity between variable blower control harness con-
nector M122 terminal 1 and ground.
OK or NG
OK >> GO TO 12.
NG >> Repair harness or connector.
12.CHECK VARIABLE BLOWER CONTROL SIGNAL CIRCUIT
1. Disconnect front air control connector.
2. Check continuity between front air control harness connector M49 terminal 13 and variable blower control harness connector
M122 terminal 2.
OK or NG
OK >> GO TO 13.
NG >> Repair harness or connector.
13.CHECK FRONT BLOWER MOTOR
Refer to "Front Blower Motor" .
OK or NG
OK >> GO TO 14.
NG >> Replace front blower motor. Refer to ATC-123, "
Removal and Installation"
14.CHECK BLOWER MOTOR GROUND CIRCUIT
Check continuity between front blower motor harness connector
M62 terminal 1 and variable blower control harness connector M122
terminal 3.
OK or NG
OK >> GO TO 15.
NG >> Repair harness or connector.
15.CHECK VARIABLE BLOWER CONTROL GROUND CIRCUIT
Check continuity between variable blower control harness connector
M122 terminal 4 and ground.
OK or NG
OK >> Replace variable blower control. Refer to ATC-143.
NG >> Repair harness or connector.
COMPONENT INSPECTION
Front Blower Motor Relay
1 - Ground. : Continuity should not exist.
WJIA1365E
13 - 2 : Continuity should exist.
WJIA1366E
1 - 3 : Continuity should exist.
WJIA1367E
4 - ground : Continuity should exist.
WJIA1368E
TROUBLE DIAGNOSISATC-97
< SERVICE INFORMATION >
C
DE
F
G H
I
K L
M A
B
AT C
N
O P
7.RECHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Refer to ATC-50, "
Operational Check (Front)" .
Does another symptom exist?
YES >> Refer to ATC-32, "How to Perform Trouble Diagnosis for Quick and Accurate Repair" .
NO >> Replace front air control. Refer to ATC-123, "
Removal and Installation" .
SYSTEM DESCRIPTION
The front air control controls compressor operation based on ambient and intake temperature and a signal
from ECM.
Low Temperature Protection Control
The front air control will turn the compressor ON or OFF as determined by a signal detected by the intake sen-
sor and the ambient sensor.
When intake air temperature is higher than the preset value, the compressor turns ON. The compressor turns
OFF when intake air temperature is lower than the pres et value. That preset value is dependent on the ambi-
ent temperature, refer to the following table.
DIAGNOSTIC PROCEDURE FOR MAGNET CLUTCH
SYMPTOM: Magnet clutch does not engage when A/C switch is ON.
1.CHECK INTAKE AND AMBIENT SENSOR CIRCUITS
Check intake and ambient sensors. Refer to ATC-48, "
A/C System Self-Diagnosis Function" .
OK or NG
OK >> GO TO 2.
NG >> • Malfunctioning intake sensor. Refer to ATC-120, "
Intake Sensor Circuit" .
• Malfunctioning ambient sensor. Refer to ATC-114, "
Ambient Sensor Circuit".
2.PERFORM AUTO ACTIVE TEST
Refer to PG-20, "
Auto Active Test".
Does magnet clutch operate?
Ambient temperature °C ( °F) C o m p r e s s o r O N i n ta k e
temperature °C ( °F) Compressor OFF in-
take temperature °C ( °F)
0 (32) 2.5 (37) 2.0 (36)
10 (50) 2.5 (37) 2.0 (36)
20 (68) 2.5 (37) 1.5 (35)
30 (86) 2.0 (36) 0.5 (33)
40 (104) 2.0 (36) 0.5 (33)
50 (122) 2.0 (36) 0.5 (33)
WJIA1369E
ATC-98
< SERVICE INFORMATION >
TROUBLE DIAGNOSIS
YES or NO
YES >> • WITH CONSULT-IIGO TO 5.
• WITHOUT CONSULT-II GO TO 6.
NO >> Check 10A fuse (No. 42, located in IPDM E/R), and GO TO 3.
3.CHECK CIRCUIT CONTINUITY BETW EEN IPDM E/R AND COMPRESSOR
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and compressor (magnet clutch) connector.
3. Check continuity between IPDM E/R harness connector E119 terminal 11 and compressor harness connector F3 terminal 1.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4.CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct cur-
rent to terminal.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-28, "Removal and
Installation of IPDM E/R".
NG >> Replace magnet clutch. Refer to ATC-155, "
Removal
and Installation for Compressor Clutch".
5.CHECK BCM INPUT (COMPRESSOR ON) SIGNAL
Check compressor ON/OFF signal. Refer to ATC-30, "
CONSULT-II
Function (HVAC)" .
OK or NG
OK >> GO TO 8.
NG >> GO TO 6.
6.CHECK CIRCUIT CONTINUITY BETWEE N BCM AND FRONT AIR CONTROL
1. Turn ignition switch OFF.
2. Disconnect BCM connector and front air control connector.
3. Check continuity between BCM harness connector M18 terminal 27 and front air control harness connector M49 terminal 12.
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
11 – 1 : Continuity should exist.
WJIA0560E
SJIA0197E
A/C SW ON : COMP ON SIG ON
A/C SW OFF : COMP ON SIG OFF
WJIA0469E
27 - 12 Continuity should exist.
WJIA1443E
TROUBLE DIAGNOSISATC-99
< SERVICE INFORMATION >
C
DE
F
G H
I
K L
M A
B
AT C
N
O P
7.CHECK VOLTAGE FOR FRONT AIR CO NTROL (COMPRESSOR ON SIGNAL)
1. Reconnect BCM connector and front air control connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 12 and ground.
OK or NG
OK >> GO TO 8.
NG-1 >> If the voltage is approx. 5V when A/C switch is ON, replace front air control. Refer to ATC-123,
"Removal and Installation".
NG-2 >> If the voltage is approx. 0V when A/C switch is OFF, replace BCM. Refer to BCS-24, "
BCM".
8.CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT-II
1. Start engine.
2. Check voltage of refrigerant pressure sensor. Refer to EC-638
.
WITHOUT CONSULT-II
1. Start engine.
2. Check voltage between ECM harness connector F54 terminal
70 and ground.
OK or NG
OK >> • WITH CONSULT-II GO TO 9.
• WITHOUT CONSULT-II GO TO 10.
NG >> Refer to EC-638
.
9.CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to ATC-30, "
CONSULT-II Function
(HVAC)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10.CHECK CIRCUIT CONTINUITY BETWEE N BCM AND FRONT AIR CONTROL
Te r m i n a l s
Condition Voltage
(+)
(-)
Front air con-
trol connec- tor Te r m i n a l N o .
M49 12 Ground A/C switch: ON Approx. 0V
A/C switch: OFF Approx. 5V
WJIA0449E
Te r m i n a l s
Condition Voltage
(+)
(-)
ECM con-
nector Te r m i n a l N o .
F54 70 Ground A/C switch: ON Approx. 0.36 - 3.88V
LJIA0124E
FRONT BLOWER CONTROL
DIAL ON : FAN ON SIG ON
FRONT BLOWER CONTROL
DIAL OFF : FAN ON SIG OFF
WJIA0469E
ATC-100
< SERVICE INFORMATION >
TROUBLE DIAGNOSIS
1. Turn ignition switch OFF.
2. Disconnect BCM connector and front air control connector.
3. Check continuity between BCM harness connector M18 terminal28 and front air control harness connector M49 terminal 10.
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
11 .CHECK VOLTAGE FOR FRONT AIR CONTROL (FAN ON SIGNAL)
1. Reconnect BCM connector and front air control connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 10 and ground.
OK or NG
OK >> GO TO 12.
NG-1 >> If the voltage is approx. 5V when blower moto r is ON, replace front air control. Refer to ATC-123,
"Removal and Installation" .
NG-2 >> If the voltage is approx. 0V when blower motor is OFF, replace BCM. Refer to BCS-24, "
BCM".
12.CHECK CAN COMMUNICATION
Check CAN communication. Refer to LAN-4
.
•BCM – ECM
• ECM – IPDM E/R
• ECM – Front air control
OK or NG
OK >> Inspection End.
NG >> Repair or replace malfunctioning part(s).
Insufficient CoolingINFOID:0000000003533260
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.CONFIRM SYMPTOM BY PERFORMING OPER ATIONAL CHECK - TEMPERATURE DECREASE
1. Press the AUTO switch.
2. Turn temperature control dial (driver) counterclockwise until 16 ° C (60 ° F) is displayed.
3. Check for cold air at discharge air outlets.
Can the symptom be duplicated?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Refer to ATC-50, "
Operational Check (Front)" .
Does another symptom exist?
28 - 10 Continuity should exist.
WJIA0450E
Te r m i n a l s
Condition Voltage
(+)
(-)
Front air con-
trol connector Te r m i n a l N o .
M49 10 Ground A/C switch: ON
Blower motor
operates
Approx. 0V
A/C switch: OFF Approx. 5V
WJIA0451E
AV-22
< SERVICE INFORMATION >
AUDIO
42 (R) 41 (G)Audio left
channel
sound signal
from satel-
lite radio
tunerInput ONReceive audio
signalNo sound from satel-
lite radio tuner left
channel.
44 (W) 43 (B)Audio right
channel
sound signal
from satel-
lite radio
tunerInput ONReceive audio
signalNo sound from satel-
lite radio tuner right
channel.
45 –Shield
ground (au-
dio signal)–– – 0V –
46 –Shield
ground (da-
ta)–– – 0V –
48 (L) GroundSatellite ra-
dio tuner re-
quest to
audio unitInput ONTurn audio unit
ON 5VSatellite radio tuner
does not operate
properly.
49 (O/L) Ground Audio RX Input ONOperate audio
volume Satellite radio tuner
audio information
does not display
properly.
50 (W/L) Ground Audio TX Output ONOperate audio
volume Satellite radio tuner
audio information
does not display
properly.
65 (O/L) Ground Audio RX Input ONOperate audio
volume Audio does not oper-
ate properly. Te r m i n a l
(Wire color)
ItemSignal
input/
outputCondition
Reference value
(Approx.)Example of symptom
+–Ignition
switchOperation
SKIA0177E
SKIA0177E
SKIA4403E
SKIA4402E
SKIA4403E