Page 361 of 444
0-10
RODIUS 2007.07
6810-20
AIR CONDITIONING SYSTEM
2. AIR CONDITIONER MODULE WIRING AND LAYOUT
1) Front Air Conditioner Module
Wiring layout
Components
Air source selection
door actuatorAir conditioner filterEvaporator
Blower
motor
Blower high
speed relay
Heater core
Page 362 of 444
0-11
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20
2) Rear Air Conditioner Module
Wiring layout
Components
Roof air conditioner duct
Blower motor
EvaporatorAir mixer door actuator
Rear floor heater duct
Mixer door
Heater coreHeater &
air conditioner pipes
Page 363 of 444
0-12
RODIUS 2007.07
6810-20
AIR CONDITIONING SYSTEM
3. AIR CONDITIONER AND HEATER PIPE LAYOUT
Page 364 of 444

0-13
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20
4. SENSORS AND ACTUATORS
1) Sun Sensor
It is installed on the upper left end of instrument panel. It is using characteristics that the
amount of current changes according to amount of light on the photosensitive surface. Photo
diode, converts the changes in light intensity into electrical changes, detects the amount of light
coming through windshield and changes it into current and then sends the signal to FATC
controller.
(1) Inspection
Remove the sun sensor and measure the current between terminals under sunlight.
Measure the current again under shade. It is in normal conditions if the measured value is
less than the measured value under sunlight.
Turn the ignition switch to “ON” position.
Measure the voltage to the sun sensor from FATC connector. (approx. 2.5 V under sunlight
and 4.8 V under shade.)
If the voltage value cannot be measured, check the circuit for open. If the measured value is
within the specified range, replace the FATC controller. 1.
2.
3.
4.
5.
Page 365 of 444
0-14
RODIUS 2007.07
6810-20
AIR CONDITIONING SYSTEM
2) Active Incar/Humidity Sensor (AIH Sensor)
The AIH sensor is installed at the driver side instrument panel undercover. It is a sensor that
detects interior temperature and humidity.
(1) Location
(2) Functions
Interior temperature sensor
▶
This sensor is a negative temperature coefficient (NTC) thermistor and detects the interio
r
temperature with air coming from senor hole and then sends the voltage value according to the
changed resistance to FATC controller.
Humidity sensor
▶
This sensor detects the interior humidity with humidity cell and then sends the voltage value
according to the changed humidity to FATC controller.
Humidity
sensor
Active incar sensor
(interior temperature
sensor)
Page 366 of 444
0-15
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20
(3) Inspection
If the active incar sensor defect code (DTC 1) and the humidity sensor defect code (DTC 10)
are set, check as below:
Air conditioner controller
Air conditioner controller connector (based on wiring) AIH sensor (based on sensor)
Active incar sensor
▶
Remove the integrated AIH sensor and measure the resistance between terminal No. 5 and
6 on the sensor connector. (standard: approx. 25°C, 2.2 kΩ)
If the measured value is out of the specified range, replace the AIH sensor. If the measured
values are within the specified range, check as below.
Turn the ignition switch to ON position and measure the voltage to active incar sensor from
the FATC controller connector. (standard: approx. 2 V at 25°C)
If the voltage value cannot be measured, check the circuit for open. If the measured value is
within the specified range, replace the FATC controller.
1.
2.
3.
4.
Page 367 of 444
0-16
RODIUS 2007.07
6810-20
AIR CONDITIONING SYSTEM
Humidity sensor ▶
Apply 5 V to terminal No. 1 and 3 on the humidity sensor connector.
Connect the positive (+) probe of a tester on No. 2 terminal and the negative (-) probe on
No. 3 terminal, and measure the output voltage while the voltage is applied.
(output voltage: approx. 0.8 ~ 3.4 V)
Check whether the output voltage is changed when blowing into the inlet of the sensor. I
f
there is a voltage change, the sensor is in normal condition. However, if the voltage is not
changed, replace the humidity sensor.
In addition, if the output voltage is extremely high or low even in the specified range, replace
the humidity sensor. 1.
2.
3.
4.
Page 368 of 444

0-17
AIR CONDITIONING SYSTEM
RODIUS 2007.07
6810-20
5. AIR QUALITY SYSTEM (AQS)
1) Components of AQS
Air Quality System (AQS) changes the air source selection to recirculation mode when polluted
air is detected through AQS sensor. The air source selection returns back to fresh air intake
mode after a specified period or the polluted air is disappeared.
AQS sensor and ambient temperature sensor
AQS sensor
Ambient
temperature
sensor
Connector
AQS and air source selection switch
The AQS switch is integrated with the air source selection switch.
AUTO Mode
The air source is not changed when pressing the AQS and air
source selection switch in “AUTO” mode. However, the
indicator on the switch turned ON/OFF. In other words, the air
source cannot be changed to recirculation mode in AUTO mode
by just pressing the switch. To change the air source to
recirculation mode in AUTO mode, get into Manual mode first,
then press the air source selection switch.
Manual Mode
To change the AQS mode to Manual mode from AUTO mode,
use the MODE switch or the fan speed control dial. In Manual
mode, the “AUTO” symbol on the display is disappeared.
When pressing the AQS and air source selection switch, the
mode is changed in order of AQS LED ON, AQS LED OFF
(fresh air), and air source LED ON (recirculation).
The figure shows that the mode has been changed to the
recirculation mode from fresh air mode under AQS mode (AQS
LED ON) after detecting the polluted outside air.