Page 638 of 2896

INTELLIGENT KEY SYSTEM
BL-149
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
3. CHECK STOP LAMP SWITCH OPERATION
Check continuity between stop lamp switch terminals 1 and 2.
OK or NG
OK >> GO TO 4.
NG >> Replace stop lamp switch.
4. CHECK STOP LAMP SWITCH CIRCUIT
1. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 26 and stop lamp switch harness connector (B)
E13 terminal 2.
2. Check continuity between Intelligent Key unit harness connector
M52 terminal 26 and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Repair or replace harness.
Stop Lamp Switch Check (With M/T)EIS009D9
1. CHECK STOP LAMP SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect Intelligent Key unit connector.
3. Check voltage between Intelligent Key unit harness connector
M52 terminal 26 and ground.
OK or NG
OK >> Stop lamp switch is OK.
NG >> GO TO 2.
Component Terminals Condition Continuity
Stop lam p
switch12Brake pedal depressed Yes
Brake pedal not depressed No
WIIA1256E
26 - 2 : Continuity should exist.
26 - Ground : Continuity should not exist.
WIIA1257E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M52 26 GroundBrake pedal
depressedBattery volt-
age
Brake pedal
released0
WIIA1207E
Page 639 of 2896

BL-150
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
2. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Disconnect stop lamp switch connector.
2. Check voltage between stop lamp switch harness connector
E13 terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between stop lamp switch
power supply circuit and fuse.
3. CHECK STOP LAMP SWITCH OPERATION
Check continuity between stop lamp switch terminals 1 and 2.
OK or NG
OK >> GO TO 4.
NG >> Replace stop lamp switch.
4. CHECK STOP LAMP SWITCH CIRCUIT
1. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 26 and stop lamp switch harness connector (B)
E13 terminal 2.
2. Check continuity between Intelligent Key unit harness connector
M52 terminal 26 and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Repair or replace harness.1 - Ground : Battery voltage
WIIA1208E
Component Terminals Condition Continuity
Stop lamp
switch12Brake pedal depressed Yes
Brake pedal not depressed No
WIIA1209E
26 - 2 : Continuity should exist.
26 - Ground : Continuity should not exist.
WIIA1210E
Page 640 of 2896

INTELLIGENT KEY SYSTEM
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
Check CVT Device (Park Position Switch) CheckEIS009DA
1. CHECK CVT DEVICE (PARK POSITION SWITCH) INPUT SIGNAL
1. Turn ignition switch OFF.
2. While pressing the ignition knob switch, check voltage between Intelligent Key unit harness connector
M52 terminal 10 and ground.
OK or NG
OK >> Replace Intelligent Key unit. Refer to BL-160, "Removal
and Installation of Intelligent Key Unit" .
NG >> GO TO 2.
2. CHECK CVT DEVICE (PARK POSITION SWITCH)
1. Disconnect CVT device (park position switch) connector.
2. Check continuity between CVT device (park position switch) terminals 6 and 8.
OK or NG
OK >> GO TO 3.
NG >> Replace CVT device (park position switch).
3. CHECK PARK POSITION SWITCH GROUND CIRCUIT
Check continuity between CVT device (park position switch) harness
connector M38 terminal 6 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M52 10 GroundSelector lever is in "P" position 0
Other than above Battery voltage
WIIA1258E
Component Terminals Condition Continuity
CVT device
(park position
switch)68Selector lever is in "P" position Yes
Other than above No
WIIA1259E
6 – Ground : Continuity should exist.
WIIA1260E
Page 641 of 2896

BL-152
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
4. CHECK PARK POSITION SWITCH CIRCUIT
1. Disconnect Intelligent Key unit connector.
2. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 10 and CVT device (park position switch) har-
ness connector (B) M38 terminal 8.
3. Check continuity between Intelligent Key unit harness connector
(A) M52 terminal 10 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
5. CHECK INTELLIGENT KEY OUTPUT SIGNAL
1. Connect Intelligent Key unit connector and CVT device (park position switch) connector.
2. Check voltage between Intelligent Key unit connector M52 terminal 10 and ground.
OK or NG
OK >> CVT device (park position switch) circuit is OK.
NG >> Replace Intelligent Key unit. Refer to BL-160, "
Removal
and Installation of Intelligent Key Unit" . 10 – 8 : Continuity should exist.
10 – Ground : Continuity should not exist.
WIIA1261E
ConnectorTerminal
ConditionVoltage (V)
(Approx.)
(+) (-)
M52 10 GroundSelector lever is in “P” position 0
Other than above Battery voltage
WIIA1258E
Page 642 of 2896
INTELLIGENT KEY SYSTEM
BL-153
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
“P-SHIFT” Warning Lamp (With CVT) CheckEIS009DB
1. CHECK WARNING LAMP OPERATION
With CONSULT-II
Check “INDICATOR” in “ACTIVE TEST” mode with CONSULT-
II.
Select “KNOB ON”.
“P-SHIFT” warning lamp should illuminate.
Without CONSULT-II
1. Turn ignition switch OFF.
2. While monitoring the combination meter warning lamps, turn
ignition switch ON. "P-SHIFT" warning lamp should illuminate
for 1 second to perform a bulb check.
OK or NG
OK >> INSPECTION END
NG >> Check combination meter. Refer to DI-5, "
COMBINATION METERS" .
PIIB4356E
WIIA1262E
Page 643 of 2896
BL-154
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
“LOCK” Warning Lamp (With M/T) CheckEIS009DC
1. CHECK WARNING LAMP OPERATION
With CONSULT-II
Check “INDICATOR” in “ACTIVE TEST” mode with CONSULT-
II.
Select “KNOB ON”.
“LOCK” warning lamp should illuminate.
Without CONSULT-II
1. Turn ignition switch OFF.
2. While monitoring the combination meter warning lamps, turn
ignition switch ON. "LOCK" warning lamp should illuminate for 1
second to perform a bulb check.
OK or NG
OK >> INSPECTION END
NG >> Check combination meter. Refer to DI-5, "
COMBINATION METERS" .
PIIB4356E
WIIA1263E
Page 644 of 2896
INTELLIGENT KEY SYSTEM
BL-155
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: June 20062007 Versa
“KEY” Warning Lamp (RED) CheckEIS009DD
1. CHECK WARNING LAMP OPERATION
With CONSULT-II
Check “INDICATOR” in “ACTIVE TEST” mode with CONSULT-
II.
Select “RED ON”.
“KEY” warning lamp (red) should illuminate.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Ensure Intelligent Key is outside and away from the vehicle.
3. While monitoring the combination meter warning lamps, push
the ignition knob switch.
4. The "KEY" warning lamp (red) should illuminate indicating that
the Intelligent Key is not nearby.
OK or NG
OK >> INSPECTION END
NG >> Check combination meter. Refer to DI-5, "
COMBINATION METERS" .
PIIB4356E
WIIA1264E
Page 645 of 2896

BL-156
INTELLIGENT KEY SYSTEM
Revision: June 20062007 Versa
“KEY” Warning Lamp (GREEN) CheckEIS009DE
1. CHECK WARNING LAMP OPERATION
With CONSULT-II
Check “INDICATOR” in “ACTIVE TEST” mode with CONSULT-
II.
Select “BLUE ON”.
“KEY” warning lamp (green) should illuminate.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Ensure Intelligent Key is in your possession inside the vehicle.
3. While monitoring the combination meter warning lamps, push
the ignition knob switch.
4. The "KEY" warning lamp (green) should illuminate indicating
that the Intelligent Key is nearby.
OK or NG
OK >> INSPECTION END
NG >> Check combination meter. Refer to DI-5, "
COMBINATION METERS" .
Check Warning Chime in Combination MeterEIS0092R
1. CHECK WARNING CHIME OPERATION
With CONSULT-II
Check “INSIDE BUZZER” in “ACTIVE TEST” mode with CON-
SULT-II.
Touch “TAKE OUT”, “KNOB” and “KEY” on “ACTIVE TEST”
screen.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
PIIB4356E
WIIA1264E
Does each warning chime sound?
PIIB6619E