Page 1455 of 3383
EC-244Revision: November 2009
DTC P0133, P0153 A/F SENSOR 1
2006 QX56
Wiring DiagramUBS00N6V
BANK 1
BBWA2111E
Page 1462 of 3383

DTC P0133, P0153 A/F SENSOR 1EC-251
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
8. CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between A/F sensor 1 terminal and ECM terminal as follows. Refer to Wiring Diagram.
4. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
5. Also check harness for short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK AIR FUEL RATIO (A/F) SENSOR 1 HEATER
Refer to EC-162, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> GO TO 13.
10. CHECK MASS AIR FLOW SENSOR
Refer to EC-178, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace mass air flow sensor.
A/F sensor 1 terminal ECM terminal
Bank1 11
6
27 5
53 5
65 6
Bank 2 17
6
27 7
55 7
65 8
Continuity should exist.
Bank 1 Bank 2
A/F sensor 1 terminal ECM terminal A/F sensor 1 terminal ECM terminal 11 617 6
27 527 7
53 555 7
65 665 8
Continuity should not exist.
Page 1467 of 3383
EC-256Revision: November 2009
DTC P0137, P0157 HO2S2
2006 QX56
Wiring DiagramUBS00H8G
BANK 1
BBWA1678E
Page 1472 of 3383

DTC P0137, P0157 HO2S2EC-261
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
3. CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between ECM terminal 78 and HO2S2 terminal 4. Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal and HO2S2 terminal as follows. Refer to Wiring Diagram.
2. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors. Continuity should exist.
BBIA0435E
DTC
Te r m i n a l s
Bank
ECM Sensor
P0137 5511
P0157 7412
Continuity should exist.
DTC Te r m i n a l s
Bank
ECM Sensor
P0137 5511
P0157 7412
Continuity should not exist.
Page 1478 of 3383
DTC P0138, P0158 HO2S2EC-267
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
Wiring DiagramUBS00N73
BANK 1
BBWA1678E
Page 1482 of 3383

DTC P0138, P0158 HO2S2EC-271
C
DE
F
G H
I
J
K L
M A
EC
Revision: November 2009 2006 QX56
2. CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect heated oxygen sensor 2 harness connector.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 78 and HO2S2 terminal 4. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal and HO2S2 terminal as follows. Refer to Wiring Diagram.
2. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors. Continuity should exist.
BBIA0435E
DTC
Te r m i n a l s
Bank
ECM Sensor
P0138 5511
P0158 7412
Continuity should exist.
DTC Te r m i n a l s
Bank
ECM Sensor
P0138 5511
P0158 7412
Continuity should not exist.
Page 1485 of 3383

EC-274Revision: November 2009
DTC P0138, P0158 HO2S2
2006 QX56
3. CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between ECM terminal 78 and HO2S2 terminal 4. Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal and HO2S2 terminal as follows. Refer to Wiring Diagram.
2. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors. Continuity should exist.
BBIA0435E
DTC
Terminals
Bank
ECM Sensor
P0138 5511
P0158 7412
Continuity should exist.
DTC Terminals
Bank
ECM Sensor
P0138 5511
P0158 7412
Continuity should not exist.
Page 1491 of 3383
EC-280Revision: November 2009
DTC P0139, P0159 HO2S2
2006 QX56
Wiring DiagramUBS00H2S
BANK 1
BBWA1678E