2006 DODGE RAM SRT-10 ignition

[x] Cancel search: ignition

Page 4943 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 10.RUN THE ACTUATOR DTC DETECTION TEST
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetectio

Page 4944 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual B1001–A/C SWITCH REQUEST INPUT CIRCUIT LOW (SINGLE-ZONE)
For a complete wiring diagramRefer to Section 8W.
Theory of Operation
The A/C mode switch input changes when the switch is pushed down. A sto

Page 4945 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.CHECK FOR NORMAL A/C MODE SWITCH & STATUS INDICATOR FUNCTION
Turn the ignition on.
Turn the blower control on.
Press the A/C mode switch on and off several times while observing the A/C status indic

Page 4946 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual B1016–REAR DEFROST SWITCH REQUEST INPUT CIRCUIT LOW (SINGLE-ZONE)
For a complete wiring diagramRefer to Section 8W.
Theory of Operation
The Rear Defrost mode switch input changes when the switch is

Page 4947 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.CHECK FOR NORMAL REAR DEFROST MODE SWITCH & STATUS INDICATOR FUNCTION
Turn the ignition on.
Press the Rear Defrost mode switch on and off several times while observingthe status indicator.
Does the

Page 4949 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on.
Set Condition:
If the Evaporator Temperature Sensor input is out of range toward the low voltage threshold, (A/D counts reach
low threshold of 3). This DTC has a

Page 4950 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 2.CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C21) Evap

Page 4952 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on.
Set Condition:
If the Evaporator Temperature Sensor input is out of range toward the high voltage threshold, (A/D counts
reach high threshold of 253). This DTC ha