2006 DODGE RAM SRT-10 battery

[x] Cancel search: battery

Page 484 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
Engine running.
Set Condition:
Fuel pressure is above a calibrated value for a calibrated amount of time.
Possible Causes
FUEL CONTROL ACTUATOR (FCA)
FUEL PRESSURE SENSOR
INTERMITTENT

Page 488 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on and battery voltage greater than 10.4 volts.
Set Condition:
The circuit voltage to the ECM falls below a calibrated threshold for a certain period of time.
Possibl

Page 491 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 8.(K616) SIGNAL CIRCUIT SHORTED TO GROUND
Measure the resistance between the (K616) signal circuit in the inlet Air
Pressure sensor connector and battery negative.
Is the resistance greater than 100 K

Page 493 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on and battery voltage greater than 10.4 volts.
Set Condition:
The circuit voltage to the ECM is above a calibrated threshold for a certainperiod of time.
Possible Ca

Page 494 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.INLET AIR PRESSURE SENSOR
While monitoring scan tool, use a jumper wire to connect the (K690)
Return circuit to the (K616) signal circuit at the Inlet Air Pressure sensor
harness connector.
Does the

Page 500 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on and battery voltage greater than 10.4 volts.
Set Condition:
The circuit voltage to the ECM falls below a calibrated threshold for a certain period of time.
Possibl

Page 505 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With ignition on and battery voltage greater than 10.4 volts.
Set Condition:
The circuit voltage to the ECM is above a calibrated threshold for a certainperiod of time.
Possible Causes

Page 512 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With ignition on and battery voltage greater than 10.4 volts.
Set Condition:
The circuit voltage to the ECM falls below a calibrated threshold for a certain period of time.
Possible Ca