INFINITI FX35 2005  Service Manual GW-96
REAR WINDOW DEFOGGER
Revision: 2005 July 2005 FX
7. Select diagnosis mode,“DATA MONITOR” and “ACTIVE TEST” 
are available.
DATA MONITOR 
Display Item List 
ACTIVE TEST 
Display Item List

Page 3377 of 4731

INFINITI FX35 2005  Service Manual GW-100
REAR WINDOW DEFOGGER
Revision: 2005 July 2005 FX
3. CHECK BCM OUTPUT SIGNAL 
1. Connect BCM connector. 
2. Turn ignition switch ON.
3. Check voltage between BCM connector M3 terminal 9 and  gro

Page 3378 of 4731

INFINITI FX35 2005  Service Manual REAR WINDOW DEFOGGER GW-101
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
GW 
Revision: 2005 July  2005 FX
3. CHECK REAR WINDOW DEFOGGER RELAY 
Check continuity between rear window defogger terminals 3 and 5, 6

Page 3379 of 4731

INFINITI FX35 2005  Service Manual GW-102
REAR WINDOW DEFOGGER
Revision: 2005 July 2005 FX
6. CHECK REAR WINDOW DEFOGGER RELAY OUTPUT SIGNAL 
1. Connect IPDM E/R connector and rear window defogger relay. 
2. Turn ignition switch ON.
3.

Page 3380 of 4731

INFINITI FX35 2005  Service Manual REAR WINDOW DEFOGGER GW-103
C 
D  E 
F 
G  H 
J 
K  L 
M  A 
B
GW 
Revision: 2005 July  2005 FX
3. CHECK REAR WINDOW DEFOGGER RELAY CIRCUIT 
1. Turn ignition switch OFF. 
2. Remove rear window defogge

Page 3400 of 4731

INFINITI FX35 2005  Service Manual IDX-7
A 
C 
D  E 
F 
G  H 
I 
J 
K  L 
B
IDX
ALPHABETICAL INDEX
Pressure switch 6  ...............................  
AT-164, AT-181
Pressure test (A/T)  ............................................

Page 3421 of 4731

INFINITI FX35 2005  Service Manual LAN-2Revision: 2005 July 2005 FX 
Display Unit Circuit Inspection  ............................. 
... 74 
Data Link Connector Circuit Inspection  ...............  ... 74 
BCM Circuit Inspection  .....

Page 3422 of 4731

INFINITI FX35 2005  Service Manual LAN-3
C 
D  E 
F 
G  H 
I 
J 
L 
M  A 
B
LAN 
Revision: 2005 July  2005 FX 
ECM Circuit Inspection ........................................ 
. 247 
TCM Circuit Inspection  ............................