Page 2372 of 3870

ADJUSTMENT 1. Select a quiet area for testing. Duplicate conditions as much as possible.
Switch the compressor on and off several times to clearly identify compressor
noise. To duplicate high ambient conditions (high head pressure), restrict air
flow through the condenser. Install a manifold gauge set to make sure
discharge pressure doesn't exceed 2,070 kPa (300.2 psi).
2. Tighten all compressor mounting bolts, clutch mounting bolt, and compressor
drive belt. Check to assure clutch coil is tight (no rotation or wobble).
3. Check refrigerant hoses for rubbing or interference that can cause unusual
noises.
4. Check refrigerant charge. (Refer to
CHARGING
and
DISCHARGING
).
5. Recheck compressor noise as in Step 1 .
6. If noise still exists, loosen compressor mounting bolts and retighten. Repeat
Step 1 .
7. If noise continues, replace compressor and repeat from Step 1 .
POWER RELAY CHECK FRONT BLOWER RELAY CONTINUITY CHECK
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2373 of 3870
Fig. 277: Identifying Front Blower Relay
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
FRONT BLOWER RELAY CONTINUITY CHART
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2374 of 3870
A/C COMPRESSOR CLUTCH RELAY CONTINUITY CHECK BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
4 - 5
Open circuit
Connect terminal 1 to the
positive battery terminal
Connect terminal 3 to the
negative battery terminal
4 - 5
Less than 2 ohms
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2375 of 3870
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2376 of 3870
Fig. 278: Identifying A/C Compressor Clutch Relay
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
A/C COMPRESSOR CLUTCH RELAY CONTINUITY CHART
FAN CONTROL RELAY CONTINUITY CHECK BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
1 - 4
Open circuit
Connect terminal 2 to the
positive battery terminal
Connect terminal 3 to the
negative battery terminal
1 - 4
Less than 2 ohms
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2377 of 3870
Fig. 279: Identifying Fan Control Relay
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2378 of 3870

FAN CONTROL RELAY CONTINUITY CHART
IDLE-UP OPERATION CHECK 1. Before inspection and adjustment, set vehicle in the following condition:
Engine coolant temperature: 80 - 90 °C (176.0 - 194.0 °F) Lights, electric cooling fan and accessories: OFF Transmission: Neutral ("N" or "P" position) Steering wheel: Straightforward
2. Check whether or not the idle speed is the standard value.
Refer to
CURB IDLE SPEED CHECK
.
Standard value: 680 +/- 50 r/min
3. Turn on the air conditioning switch and the blower speed selection dial. Engine
idling speed should be within the standard value:
Standard value
At low pressure: 680 +/- 50 r/min
At middle pressure: 730 +/- 50 r/min
At high pressure: 750 +/- 50 r/min
BATTERY VOLTAGE
TESTER
CONNECTION
SPECIFIED
CONDITION
Not applied
2 - 4
Open circuit
Connect terminal 1 to the
positive battery terminal
Connect terminal 3 to the
negative battery terminal
2 - 4
Less than 2 ohms
NOTE: The powertrain control module determines whether the
A/C load is low or high according to the output signal
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2379 of 3870
HEATER CONTROL ASSEMBLY AND A/C SWITCH REMOVAL AND INSTALLATION Fig. 280: Removing And Installing Heater Control Assembly
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR
UNIT
from the A/C-ECU.
NOTE: It is not necessary to make an adjustment, because the
idling speed is automatically adjusted by the ISC
system. If, however, a deviation from the standard value
occurs for some reason, check the ISC system. (Refer
to CURB IDLE SPEED CHECK
).
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor