Page 2260 of 3870
Fig. 188: Locating Connector C
-202
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2. Measure the voltage between terminal 5 and ground.
The measured value should be approximately 12 volts (battery
positive voltage).
Q: Is the measured voltage approx. 12 V?
YES:
Go to Step 9 .
NO:
Go to Step 8.
Fig. 189: Measuring Voltage Between Terminal 5 And Ground
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2261 of 3870
STEP 8. Check the wiring harness between front blower relay connector
C-202 (terminal 5) and fusible link (1).
Fig. 190: Identifying Fusible Link
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2262 of 3870
Fig. 191: Locating Connector C
-216
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2263 of 3870
Q: Is the wiring harness between front blower relay connector C-202
(terminal 5) and fusible link (1) in good condition?
YES:
The front blower motor should operate normally.
NO:
Repair the wiring harness. The front blower motor should operate
normally.
STEP 9. Check the wiring harness between A/C-ECU connector C-16
(terminal 9) and front blower relay connector C-202 (terminal 3).
NOTE: Also check junction block connector C-216 for loose,
corroded, or damaged terminals, or terminals pushed
back in the connector. If junction block connector C-216
is damaged, repair or replace the connector as
described in HARNESS CONNECTOR INSPECTION
.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2264 of 3870
Fig. 192: Locating Connector C
-16
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2265 of 3870
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2266 of 3870
Fig. 193: Locating Connector C
-211
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
Q: Is the wiring harness between A/C-ECU connector C-16 (terminal 9)
and front blower relay connector C-202 (terminal 3) in good condition?
YES:
Go to Step 10.
NO:
Repair the wiring harness. The front blower motor should operate
normally.
STEP 10. Check the wirin
g harness between front blower motor connector
C-111 (terminal 1) and front blower relay connector C-202 (terminal 4). NOTE: Also check junction block connector C-211 for loose,
corroded, or damaged terminals, or terminals pushed
back in the connector. If junction block connector C-211
is damaged, repair or replace the connector as
described in HARNESS CONNECTOR INSPECTION
.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor
Page 2267 of 3870
Fig. 194: Locating Connector C
-111
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
2004 Mitsubishi Endeavor LS
2004 HVAC Heater Air Conditioning, Ventilation - Endeavor