2004 ISUZU TF SERIES section 8A

[x] Cancel search: section 8A

Page 1946 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6C-4  ENGINE FUEL (6VE1 3.5L) 
Fuel Filter 
Removal 
CAUTION:  When repair to the fuel system has been
completed, start engine  and check the fuel system
for loose connection or leakage. For the fuel

Page 1947 of 4264

ISUZU TF SERIES 2004  Workshop Manual ENGINE FUEL (6VE1 3.5L)  6C-5 
Fuel Pump Flow Test 
If reduction of fuel supply is suspected, perform the
following checks. 
1.  Make sure that there is fuel in the tank. 
2.  With the engine running,

Page 1948 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6C-6  ENGINE FUEL (6VE1 3.5L) 
Fuel Pump 
Fuel Pump and Associated Parts 
 
 
 
 RTW46FMF000401 
Legend (6) Fuel Tube/Quick Connector 
(1)  Fuel Feed Port  (7) Retainer Ring (Fuel Pump Lock) 
(2)  Fue

Page 1949 of 4264

ISUZU TF SERIES 2004  Workshop Manual ENGINE FUEL (6VE1 3.5L)  6C-7 
3.  Remove the retainer ring (7) from the fuel tank 
with the removal tool 5-8840-2602-0. 
 
 
 
 
140R100035
4. Remove slowly the fuel pump (4) from the fuel
tank as no

Page 1954 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6C-12  ENGINE FUEL (6VE1 3.5L) 
Removal 
CAUTION:  When repair to the fuel system has been
completed, start engine and check the fuel system
for loose connection or leakage. For the fuel system
diagno

Page 1955 of 4264

ISUZU TF SERIES 2004  Workshop Manual ENGINE FUEL (6VE1 3.5L)  6C-13 
Filler Neck 
Removal 
1. Remove the fuel tank. 
NOTE: Refer to "Fuel Tank" in this section. 
2. Put a marking the following point as the filler neck
assembly is restore

Page 1960 of 4264

ISUZU TF SERIES 2004  Workshop Manual 6D1-2  ENGINE ELECTRICAL (6VE1 3.5L) 
Battery 
General Description 
There are six battery fluid caps on the top of the battery.
These are covered by a paper label. 
The battery is completely sealed ex

Page 1961 of 4264

ISUZU TF SERIES 2004  Workshop Manual ENGINE ELECTRICAL (6VE1 3.5L)  6D1-3 
4. Load Test 
 1. Connect a voltmeter and a battery load tester
across the battery terminals. 
 2. 
Apply 300 ampere load for 15 seconds to remove
surface charge