COMPONENT DESCRIPTION
Mode Door Motor
The mode door motor is attached to the heater & cooling unit. It
rotates so that air is discharged from the outlet as indicated by the
front air control. Motor rotation is conveyed to a link which activates
the mode door.
DIAGNOSTIC PROCEDURE FOR MODE DOOR MOTOR
1. CHECK RESULT FROM FRONT AIR CONTROL SELF-DIAGNOSIS
Self-diagnosis code 92 is present. Refer to ATC-53, "
A/C System Self-diagnosis Function" .
YES or NO
YES >> GO TO 2.
NO >> GO TO 3.
2. CHECK POWER SUPPLY AND GROUND CIRCUITS FOR MODE DOOR MOTOR
1. Turn ignition switch OFF.
2. Disconnect front air control connector M49 and mode door
motor connector M142.
3. Check continuity between front air control harness connector
M49 terminal 5 (BR/W) and mode door motor connector M142
terminal 5 (BR/W) and between front air control harness con-
nector M49 terminal 6 (P/L) and mode door motor connector
M142 terminal 6 (P/L).
OK or NG
OK >> Replace mode door motor. Refer to ATC-152, "Removal and Installation" .
NG >> Repair or replace harness as necessary.
3. CHECK PBR REFERENCE SIGNAL VOLTAGE
1. Disconnect mode door motor connector M142.
2. Turn ignition switch ON.
3. Check voltage between mode door motor harness connector
M142 terminal 3 (Y) and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
WJIA0587E
5 - 5 : Continuity should exist.
6 - 6 : Continuity should exist.
LJIA0027E
3 - Ground : Approx. 5V
LJIA0028E
Page 474 of 3371
TROUBLE DIAGNOSIS
ATC-69
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
COMPONENT DESCRIPTION
Air Mix Door Motors
The driver and front passenger air mix door motors are attached to
the front heater & cooling unit. The rear air mix door motor is
attached to the rear heater & cooling unit. These motors rotate so
that the air mix door is opened or closed to a position set by the front
(or rear) air control. Motor rotation is then conveyed through a shaft
and the air mix door position is then fed back to the front air control
by the PBR built into the air mix door motors.
DIAGNOSTIC PROCEDURE FOR AIR MIX DOOR MOTOR (DRIVER)
1. CHECK RESULT FROM FRONT AIR CONTROL SELF-DIAGNOSIS
Self-diagnosis code 22 is present. Refer to ATC-53, "
A/C System Self-diagnosis Function" .
YES or NO
YES >> GO TO 2.
NO >> GO TO 3.
WJIA0546E
WJIA0547E
WJIA0894E
Page 485 of 3371

ATC-80
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
SYSTEM DESCRIPTION
Component Parts
Defroster door control system components are:
Front air control
Defroster door motor
PBR (Built into defroster door motor)
In-vehicle sensor
Ambient sensor
Optical sensor
Intake sensor
System Operation
The front air control determines defroster door position based on the position of the defroster switch. When the
defroster switch is rotated counterclockwise, the defroster door motor rotates directing air to the defroster
ducts. When any mode other than defroster is selected, the defroster motor rotates in the opposite direction
closing off air flow to the defroster ducts.
In the AUTO mode, the front air control determines defroster door position based on the ambient temperature,
the intake air temperature and the in-vehicle temperature.
COMPONENT DESCRIPTION
Defroster door motor
The defroster door motor is attached to the front heater & cooling
unit. The front air control sends a voltage to rotate to the defroster
door directing the air flow either to the defroster ducts, or to the floor
ducts, depending on which way the voltage and ground are applied
to the motor leads. Motor rotation is conveyed to a lever which acti-
vates the defroster door.
WJIA0961E
WJIA0592E
Page 490 of 3371
TROUBLE DIAGNOSIS
ATC-85
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Blower Speed Compensation - Sunload
When the in-vehicle temperature and the set temperature are very close, the blower will be operating at low
speed. The speed will vary depending on the sunload. During conditions of low or no sunload, the blower
operates at low speed. During high sunload conditions, the front air control causes the blower speed to
increase.
Blower Speed Control Specification
COMPONENT DESCRIPTION
Variable Blower Control
The variable blower control is located on the front heater and cooling
unit. The variable blower control receives a gate voltage from the
front air control to steplessly maintain the blower motor voltage in the
0 to 5 volt range (approx.).
DIAGNOSTIC PROCEDURE FOR BLOWER MOTOR
SYMPTOM: Blower motor operation is malfunctioning under starting
blower speed control.
WJIA0441E
WJIA0559E
WJIA0778E
Page 515 of 3371
ATC-110
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Insufficient CoolingEJS002CM
SYMPTOM: Insufficient cooling
INSPECTION FLOW
*1 .AT C - 5 6 , "Operational Check
(Front)"
*2AT C - 5 3 , "A/C System Self-diagno-
sis Function"
*3AT C - 5 5 , "SELF-DIAGNOSIS CODE
CHART"
*4 EC-410, "SYSTEM DESCRIPTION"*5AT C - 5 , "Contaminated Refrigerant"*6 .AT C - 111 , "PERFORMANCE TEST
DIAGNOSES"
*7ATC-113, "Test Reading"*8MA-12, "Checking Drive Belts"*9ATC-121, "Water Valve Circuit"
WJIA0963E
Page 519 of 3371

ATC-114
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
TROUBLE DIAGNOSES FOR UNUSUAL PRESSURE
Whenever system′s high and/or low side pressure(s) is/are unusual, diagnose using a manifold gauge. The
marker above the gauge scale in the following tables indicates the standard (usual) pressure range. Since the
standard (usual) pressure, however, differs from vehicle to vehicle, refer to preceding table (Ambient air tem-
perature-to-operating pressure table).
Both High- and Low-pressure Sides are Too High
High-pressure Side is Too High and Low-pressure Side is Too Low
Gauge indication Refrigerant cycle Probable cause Corrective action
Both high- and low-pressure sides
are too high.Pressure is reduced soon
after water is splashed on
condenser.Excessive refrigerant charge
in refrigeration cycleReduce refrigerant until speci-
fied pressure is obtained.
Air suction by cooling fan is
insufficient.Insufficient condenser cooling
performance
↓
1. Condenser fins are clogged.
2. Improper fan rotation of
cooling fan
Clean condenser.
Check and repair cooling fan
as necessary.
Low-pressure pipe is not
cold.
When compressor is
stopped high-pressure
value quickly drops by
approximately 196 kPa (2
kg/cm
2 , 28 psi). It then
decreases gradually there-
after.Poor heat exchange in con-
denser
(After compressor operation
stops, high-pressure
decreases too slowly.)
↓
Air in refrigeration cycleEvacuate and recharge sys-
tem.
Engine tends to overheat.Engine cooling systems mal-
function.Check and repair engine cool-
ing system.
An area of the low-pres-
sure pipe is colder than
areas near the evaporator
outlet.
Plates are sometimes cov-
ered with frost.
Excessive liquid refrigerant
on low-pressure side
Excessive refrigerant dis-
charge flow
Expansion valve is open a
little compared with the
specification.
↓
Improper expansion valve
adjustmentReplace expansion valve.
AC359A
Gauge indication Refrigerant cycle Probable cause Corrective action
High-pressure side is too high and
low-pressure side is too low.
Upper side of condenser and
high-pressure side are hot,
however, liquid tank is not so
hot.High-pressure tube or parts
located between compressor
and condenser are clogged or
crushed.
Check and repair or replace
malfunctioning parts.
Check lubricant for contami-
nation.
AC360A
Page 521 of 3371

ATC-116
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Low-pressure Side Sometimes Becomes Negative
Low-pressure Side Becomes Negative
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side sometimes
becomes negative.
Air conditioning system
does not function and does
not cyclically cool the com-
partment air.
The system constantly func-
tions for a certain period of
time after compressor is
stopped and restarted.Refrigerant does not dis-
charge cyclically.
↓
Moisture is frozen at expan-
sion valve outlet and inlet.
↓
Water is mixed with refriger-
ant.
Drain water from refrigerant
or replace refrigerant.
Replace liquid tank.
AC354A
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side becomes nega-
tive.
Liquid tank or front/rear side of
expansion valve′s pipe is
frosted or dewed.High-pressure side is closed
and refrigerant does not flow.
↓
Expansion valve or liquid tank
is frosted.Leave the system at rest until
no frost is present. Start it
again to check whether or not
the malfunction is caused by
water or foreign particles.
If water is the cause, initially
cooling is okay. Then the
water freezes causing a
blockage. Drain water from
refrigerant or replace refrig-
erant.
If due to foreign particles,
remove expansion valve
and remove the particles
with dry and compressed air
(not shop air).
If either of the above meth-
ods cannot correct the mal-
function, replace expansion
valve.
Replace liquid tank.
Check lubricant for contami-
nation.
AC362A
Page 526 of 3371
TROUBLE DIAGNOSIS
ATC-121
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Memory FunctionEJ S00 2CQ
SYMPTOM: Memory function does not operate.
INSPECTION FLOW
Water Valve CircuitEJS002CR
COMPONENT DESCRIPTION
Water Valve
The water valve cuts the flow of engine coolant to the front and rear
heater cores to allow for maximum cooling during A/C operation. It is
controlled by the front air control through the water valve relay.
*1ATC-60, "Power Supply and Ground
Circuit for Front Air Control"
*2AT C - 5 6 , "Operational Check (Front)"*3AT C - 5 3 , "A/C System Self-diagnosis
Function"
WJIA0797E
WJIA1015E