2004 INFINITI FX35 ground

[x] Cancel search: ground

Page 1482 of 4449

INFINITI FX35 2004  Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-141
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
17. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT I

Page 1493 of 4449

INFINITI FX35 2004  Service Manual EC-152
[VQ35DE]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse sign

Page 1495 of 4449

INFINITI FX35 2004  Service Manual EC-154
[VQ35DE]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse sign

Page 1496 of 4449

INFINITI FX35 2004  Service Manual DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-155
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 ha

Page 1501 of 4449

INFINITI FX35 2004  Service Manual EC-160
[VQ35DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
D

Page 1503 of 4449

INFINITI FX35 2004  Service Manual EC-162
[VQ35DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
D

Page 1504 of 4449

INFINITI FX35 2004  Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-163
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 ha

Page 1510 of 4449

INFINITI FX35 2004  Service Manual DTC P0101 MAF SENSOR
EC-169
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION