2. DOOR SWITCH CIRCUIT INSPECTION
1. Disconnect door switch and BCM connector.
2. Check continuity between door switch connector B26, B36, B46, B206 terminals 1 and BCM connector
M3, B14 terminals 62, 12, 63, 13.
3. Check continuity between door switch connector B26, B36, B46,
B206 terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. DOOR SWITCH INSPECTION
Check continuity between door switch terminal 1 and ground part of door switch.
OK or NG
OK >> Check door switch case ground condition.
NG >> Replace door switch.
CHECK BACK DOOR SWITCH
1. CHECK BACK DOOR SWITCH INPUT SIGNAL
Check voltage between BCM connector and ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> GO TO 2.Driver side door
1 (W) –62 (W) : Continuity should exist.
Passenger side door
1 (SB) – 12 (P/B) : Continuity should exist.
Rear door LH
1 (P) – 63 (P) : Continuity should exist.
Rear door RH
1 (P) – 13 (P/L) : Continuity should exist.
1 (W, SB, P) – Ground : Continuity should not exist.
PIIA7004E
Terminal Door switch condition Continuity
1 Ground part of door switchPushed No
Released Yes
PIIA3351E
ConnectorTerminals (Wire color)
ConditionVoltage (V)
(Approx.)
(+) (–)
B14 58 (L) GroundOPEN 0
CLOSE 9
PIIA6229E
Page 937 of 4449
BL-130
INTELLIGENT KEY SYSTEM
Revision: 2004 November 2004 FX35/FX45
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and back door closure motor connector.
3. Check continuity between BCM connector B14 terminal 58 and
back door closure motor connector D109 terminal 7.
4. Check continuity between BCM connector B14 terminal 58 and
ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BACK DOOR SWITCH
Check continuity between back door closure motor D109 terminals 7
and 8.
OK or NG
OK >> GO TO 5.
NG >> Replace back door closure motor.58 (L) – 7 (L) : Continuity should exist.
58 (L) – Ground : Continuity should not exist.
PIIA6226E
8 (B) – Ground : Continuity should exist.
PIIA6170E
Terminals Back door condition Continuity
78Open Yes
Close No
PIIA9934E
Page 938 of 4449

INTELLIGENT KEY SYSTEM
BL-131
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
5. CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Replace BCM.
Check Unlock SensorAIS004NG
1. UNLOCK SENSOR POWER SUPPLY INSPECTION
Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Unlock sensor is OK.
NG >> GO TO 2.
2. UNLOCK SENSOR CIRCUIT INSPECTION
1. Turn ignition knob LOCK position.
2. Disconnect Intelligent Key unit and front door lock assembly (driver side) connector.
3. Check continuity between Intelligent Key unit connector M34 terminal 28 (W/B) and front door lock
assembly (driver side) connector D10 terminal 4 (W).
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between Intelligent Key unit
and front door lock assembly (driver side). 58 (L) – Ground : Approx. 9V
PIIA6229E
ConnectorTerminals (Wire color)
ConditionVoltage (V)
(Approx.)
(+) (-)
M34 28 (W/B) GroundDriver side door lock is
locked5
Driver side door lock is
unlocked0
PIIA6802E
28 (W/B) – 4 (W) : Continuity should exist.
PIIA6803E
Page 949 of 4449
BL-142
INTELLIGENT KEY SYSTEM
Revision: 2004 November 2004 FX35/FX45
3. STOP LAMP SWITCH GROUND CIRCUIT INSPECTION
1. Check continuity between stop lamp switch connector E210 ter-
minal 2 (P) and Intelligent Key unit connector M34 terminal 26
(P/L).
2. Check continuity between stop lamp switch connector E210 ter-
minal 2 (P) and ground.
OK or NG
OK >> Stop lamp switch is OK.
NG >> Repair or replace harness.
Check Detention SwitchAIS004NN
1. DETENTION SWITCH INPUT SIGNAL INSPECTION
1. Turn ignition knob LOCK position.
2. Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.2 (P) - 26 (P/L) : Continuity should exist.
2 (P) - Ground : Continuity should not exist.
PIIA6801E
ConnectorTerminal
(Wire color)
ConditionVoltage (V)
(Approx.)
(+) (-)
M34 39 (R/Y) GroundWhen selector lever is locked
at the “P” position0
When selector lever is not
locked at the “P” positionBattery voltage
PIIA6805E
Page 950 of 4449
INTELLIGENT KEY SYSTEM
BL-143
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
2. DETENTION SWITCH CIRCUIT INSPECTION
1. Disconnect A/T device (detention switch) connector.
2. Check voltage between A/T device (detention switch) connector
M67 terminal 3 (R/Y) and ground. (Check harness for open.)
3. Check continuity between A/T device (detention switch) connec-
tor M67 terminals 3 (R/Y) and ground. (Check harness for
short.)
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. DETENTION SWITCH INSPECTION
Check continuity between A/T device (detention switch) terminals 2 and 3.
OK or NG
OK >> GO TO 4.
NG >> Replace back A/T device (detention switch).3 (R/Y) – Ground : Battery voltage
PIIA6806E
3 (R/Y) – Ground : Continuity should not exist.
PIIA6807E
Terminal Condition Continuity
2 – 3When selector lever is not
locked at the “P” positionNo
When selector lever is
locked at the “P” positionYe s
PIIA6808E
Page 978 of 4449

BACK DOOR AUTO CLOSURE SYSTEM
BL-171
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Back Door Closure Control Unit Power Supply and Ground Circuit CheckAIS004OK
1. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Check voltage between back door closure control unit connector
D106 terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check the following.
15A fuse [No.18, located in fuse block (J/B)]
Harness for open or short between back door closure
control unit and fuse.
2. CHECK GROUND CIRCUIT
1. Disconnect back door closure control unit connector.
2. Check continuity between back door closure control unit con-
nector D106 terminal 4 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace harness.
Half-Latch Switch CheckAIS004OL
1. CHECK HALF-LATCH SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Half-latch switch is OK.
NG >> GO TO 2.1 (R) – Ground : Battery voltage
PIIA6166E
4 (B) – Ground : Continuity should exist.
PIIA6167E
Con-
nectorTerminals (Wire color)
Back door
conditionSignal
(Reference value)
(+) (-)
D106 7 (OR) GroundFully open →
fully closed
PIIA6168E
SIIA1479J
Page 980 of 4449

BACK DOOR AUTO CLOSURE SYSTEM
BL-173
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2004 November 2004 FX35/FX45
Close Switch CheckAIS004OM
1. CHECK CLOSE SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Close switch is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door closure motor connector.
2. Check continuity between back door closure control unit con-
nector D106 terminal 8 and back door closure motor connector
D109 terminal 5.
3. Check continuity between back door closure control unit con-
nector D106 terminal 8 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
Con-
nectorTerminals (Wire color)
Back door
conditionSignal
(Reference value)
(+) (-)
D106 8 (L) GroundFully open →
fully closed
PIIA6171E
SIIA1478J
8 (L) – 5 (L) : Continuity should exist.
8 (L) – Ground : Continuity should not exist.
PIIA6174E
8 (B) – Ground : Continuity should exist.
PIIA6170E
Page 981 of 4449

BL-174
BACK DOOR AUTO CLOSURE SYSTEM
Revision: 2004 November 2004 FX35/FX45
4. CHECK BACK DOOR CLOSURE CONTROL UNIT OUTPUT SIGNAL
1. Connect back door closure control unit connector.
2. Check voltage between back door closure control unit connector
D106 terminal 8 and ground.
OK or NG
OK >> Replace back door lock assembly.
NG >> Replace back door closure control unit.
Open Switch CheckAIS004ON
1. CHECK OPEN SWITCH SIGNAL
1. Turn ignition switch OFF.
2. Check the signal between back door closure control unit connector and ground with oscilloscope.
OK or NG
OK >> Open switch is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Disconnect back door closure control unit and back door closure motor connector.
2. Check continuity between back door closure control unit con-
nector D106 terminal 9 and back door closure motor connector
D109 terminal 4.
3. Check continuity between back door closure control unit con-
nector D106 terminal 9 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.Back door is closed
8 (L) – Ground : Battery voltage
PIIA6173E
Con-
nectorTerminals (Wire color)
Back door
conditionSignal
(Reference value)
(+) (-)
D106 9 (P) GroundFully open →
fully closed
PIIA6175E
SIIA1481J
9 (P) – 4 (P) : Continuity should exist.
9 (P) – Ground : Continuity should not exist.
PIIA6176E