82A
HORN - ENGINE IMMOBILISER
82A - 15
NOTE
For the RF remote control synchronisation, after the replacement of a kit, take into
account the fol lowing situations: - for the first RF remote control, perform the “ simple synchronised procedure”;
- for the second RF remote c ontrol perform the “specific synchronised procedure” .
C. CODE REPAIRING INTRODUCTION PROCEDURE
The repairing code may be introduced only by the means of the CLIP tester. This is possible
only if when setting the contact on, the anti starting indicator blinks rapidly, this being confirmed
by the state: 10G ANTI STARTING…………………………………………….. ACTIVE
After getting from DACIA database the repairing code (based on the code from the vehicle’s
key head), perform the following operations. 1. Connect the CLIP tester to the diagnostic socket and to the battery (or to the lighter
socket) of the vehicle. 2. The anti start up indicator must blink slowly , the contact being taken off.
3. Set the contact in “M” position. The indicator must blink rapidly.
4. Select vehicle type “SUPERNOVA” and “050” equipping level.
5. Select the menu “ COMPUTER TEST” then choose “ ANTI STARTING”.
6. In the menu “ STAT E L IST” find t he state 10G “ANTI STARTING” which m ust be
“ACTIVE”.
7. Access “COMMAND MODE” then select “ACTUATORS”.
8. Select the command “ MANUAL INTRODUCTION CODE” where you will write the
repairing code (formed of four figures), then validate it with the key “ENTER”. T he message
“COMMAND IN PROGRESS” will be displayed followed by the message “FINISHED
COMMAND”.
9. Now the procedure is finished and you may start the vehicle engine.
AT TENT ION
You may perform three essays of introducing the repairing code; if aft er the third
essay the code is not yet valid, wait for 15 minutes, take off the contact and then put it
again, other t hree essays being allowed.
NOTE
This procedure does not decode the injection computer, but allows only the start of
the vehicle’s engine. After ten minutes have passed from the first introduction of the
r epairing code or after the disconnection of the battery, the vehicle’s engine cannot be
s tarted unless a new repairing code is introduced. PROCEDURES
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 16
D. SIMPLE S
YNCHRONISED PROCEDURE
This procedure allows the synchronisation of a RF remote control with E.C.U. decoder and
is to be applied in the following situations:
- the RF remote control c ode is no longer i n the range of the E.C.U. decoder re ception,
because of consecutive pushing over a 1000 time on the RF remote control button.;
- the replacement of the E.C.U. decoder with a new one;
- the replacement of the RF remote control if the E.C.U. decoder is new (E.C.U. decoder
replacement plus a RF key.)
The following operations will be performed: - take off t he contact
- push and maintain like that for about 5 seconds, the doors locking switch located on the
dashboard ; the doors actuators are performing a closing/opening course.
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system indicator, push twice the RF remote control button; the doors actuators are performing a
closing/o pening course.
- the procedure of synchronisation is finished; check the blocking/ unlocking by pushing
the RF remote control.
OBSERVAT ION
Duri ng those 10 seconds you can visualise by means of the CLIP tester the state 17G
“THE PROGRAMMING IN PROGRESS OR THE TIR/TRF
RESYNCHRONISATION” which must be ACTIVE.
E. SPECIFIC SYNCHRONISED PROCEDURE
This procedure is used for the synchronisation of the second RF key with E .C.U. decoder
and will be performed as follows:
- connect the CLIP tester to the diagnostic socket and the battery (or the lighter socket) of
the vehicle. - select the vehicle type “SUPERNOVA” and the “050” equipping level;
- select the m enu “ COMPUTERS TEST” then “ ANTI STARTING”
- enter the m enu “COMMAND MODE” and select “CONFIGURATION”
- validate the command “ PROGRAMMI NG THE SECOND TIR / TRF KEY” launching
the command from the blue button situated on the right top of the screen; the doors actuators are
performing a closing/opening course.
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system, push twice the RF remote control button; the doors will block and then unlock and the
anti starting indicator will t urn off. The second remote control is now synchronised. Check the
blocking/ unlocking by pushing the RF remote control. PROCEDURES
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 20
D)
Memorising of the new code of the injection computer
- in ACTUATORS
launch the command MANUAL INTRODUCTION CODE ; type
the repairing code of the old key kit, then validate it with the key
ENTER.
- the message “COMMAND IN PROGRESS ” will be displayed followed by the message
“FINISHED COMMAND ”.
-s et the contact on; t he anti starting LED indicator will start blinking, then take off the
contact;
-set the c ontact on for 10 seconds ; take off the contact;
- check if the engine starts with the two keys.
If the engine doesn’t start, repeat this operation (point D).
E) Key resynchronisation (remote controls)
-if the vehicle is equipped with only one remote control, its resynchronisation will be
performed as follows (simple resynchronisation);
- with t he contact taken off, push continuously on the c entra l l ocking but ton from the
dashboard, up to the moment the anti starting LED indicator remains lighted (the doors actuators
are performing a closing/opening course.) From this moment, t he operator has 10 seconds to
perform the next operation; - push twice on the remote control (the doors actuators are performing a closing/opening
course.) and the anti starting LED indicator turns off; - if the vehicle is equipped with two remotes controls, perform the simple resynchronisatio n
procedure for the first key and a specific resynchronisation procedure for the second key, with
the CLIP tester as follows: - in COMPUTER TEST select ANTISTARTING with t he c ontact t aken off, then
COMMAND MODE , CONFIGURATION ; launch the command PROGRAMMING OF
THE SECOND TIR/TIE KEY and validate (the doors actuators are performing a closing/
opening course.). Then within 10 seconds, push twice on the remote control (the doors actuators
are performing a closing/o pening course).DIAGNOSTIC
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 26
6. STATE 11G: ACTIVATE THE RF REMOTE CONTROL/ RECEIVED RF SIGNAL
INDICATION
If the 17D state is PASSIVE, do not apply the next diagnostic
because the E .C.U. decoder is unused (new).
RECOMMENDATION Perform first the remote control synchronisation Do not access the next diagnostic if the state 11G remains PASSIVE
when activating the RF remote control at the blocking and unlocking
of the doors.
Check the blocking and unlocking of the doors using the second RF remote control. If this
is one is operating, then the battery of the first RF remote control should be replaced.
Check the presence of +12 V(+DC) at the pin1 of the anti starting bushing.
Is there +12V ?
Perform using CLIP tester, the impulse detection test a t the pin 1 of the anti
starting bushing, when using the RF remote control.
Are any impulses when using the remote control ?
YES Replace the E .C.U. decoder.
NO Replace the anti starting bushing.YES
Check the isolation related to the ground of the electric wiring between:
E.C.U. decoder Pin B1 pole 1 anti starting bushing Pin B2 pole door locking switch
Pin B5 pole 3
Is the isolation related to the ground good?
YES Fix the electric wiring.
NO Replace the E .C.U. decoder.NO
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 27
7. 11 STATE: OPERATE THE RF REMOTE CONTROL / GOOD RF SIGNAL
INDICATION
Do not access the following diagnostic
unless the state 11D
RECOMMENDATION becomes ACTIVE when operating the RF remote control. Check if the keys belong to the vehicle in question.
There is a desynchronising between the code of the RF remote control and the E.C.U. decoder
if at the activation of the remote control, the 111D state remains PASSIVE and the state 11G
becomes AC TIVE for 3 seconds, then becomes PASSIVE. The blocking / unlocking of the
do ors is not possible in this case.
Apply the corresponding procedure of resynchronisation (for one or two keys).
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 36
A
LP7. UNLOCKING DOORS NOT OPERATING BY RF REMOTE CONTROL
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, these must be repaired.
Are the states 11G and 11D ACTIVE when
the RF remote control is activated?S ee the treatment states 11G and
1 1D cf. Chapter “Diagnostic”.No
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?
Replace the fuse.No
Yes
Yes
Activate the doors’ locking switch from t he
dashboard.
Are the doors blocking/ unlocking ? S
ee the treatment of the failure
“Doors blocking contact” and the
state 14 G cf. Chapter “Diagnostic”.
S ee ALP 6.
Yes
No
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 37
A
LP8. TURNING LIGHTS DO NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS
RECOMMENDATION Check the absence of the failures with the CLIP tester.
If there are failures, fix them first.
Check if the synchronisatio n of the RF remote control and the E.C.U. decoder has been performed .
Are the turning lights functioning normally at the activation of the signalling switch ?
Check the continuity and the isolation related to
the ground and the +12 V of the electric layout:
E.C.U. decoder FLASH relay
Pin B3 pole 2
Is it correct?
Repair the signalli ng system.
Check t he fuse F03 and F04.
Fix the electric layout.
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?Replace the fuse.
Disconnect the FLASH relay. Supply with
+ 12, the pole 4 of the relay. Are the l eft
turning lights turning on? Supply with +12 V
the pole 5 of the signal relay.
Are the right turning lights turning on?
Repair the electric layout from
poles 4 and 5 of the FLASH relay.
Replace the FLASH relay.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
No
No
No
Yes
Yes
Yes
Yes No
DIAGNOSTIC
vnx.su
82A
HORN - ENGINE IMMOBILISER
82A - 38
No
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
A LP9. THE CEILING LAMP DOES NOT SWITCH ON AT THE BLO CKING /
UNLOCKING OF THE DOORS OR IT REMAINS PERMANENTLY TURNED ON.
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, fix them first.
Check if t he doors are locked?
Has the ceiling lamp turned on? The ceiling lamp was in the
position “p
ermanently
lighting”. Normal
operation.Yes Yes
Unlock the doors with the RF remote control.
The ceiling is in the position “dome lighting”
Has the ceiling lamp turned on?
Check the isolation of the wiring
related to the ground on the line pinA1.
decoder ceiling
After 15 seconds, the ceiling lamp will
turn off.
Normal operation.
Was the E.C.U. decoder confi gured “With
dome ceiling ”?Configure the E.C.U. decoder with
the CLIP tester.
Check the continuity on the line
E. C.U. decoder pin A1 ceiling
Is the line good?Repair .
Check the ceiling lamp bulb.
No
No
No
Yes
Yes Yes
No
DIAGNOSTIC
vnx.su