2003 SSANGYONG MUSSO air condition

[x] Cancel search: air condition

Page 1089 of 1574

SSANGYONG MUSSO 2003  Service Manual TRANSFER CASE (PART TIME 4408)  5D1-37
Inspection and Repair 
1. 4H and 4L indicator light inspection� When turn the ignition switch to "ON" position, 4H and
4L indicator light will turn on for 0.6 se

Page 1114 of 1574

SSANGYONG MUSSO 2003  Service Manual TRANSFER CASE (TOD)  5D2-25
Error in electro - magnetic clutch : fault code “1721 ”,  “1722 ”
� Phenomenon 
1. Upon diagnosis by SCAN-100, it displays on fault
codes  “1721,1722 ”.
� Cause

Page 1120 of 1574

SSANGYONG MUSSO 2003  Service Manual TRANSFER CASE (TOD)  5D2-31
Position incoder and position 1,2,3,4 malfunction :Fault code®1750,1751,1752,1753, 1754
� Phenomenon The  ‘4WD check ’ lamp can not go out when the ignition
switch pos

Page 1157 of 1574

SSANGYONG MUSSO 2003  Service Manual SECTION 7D
FULL  AUTOMATIC  TEMPERATURECONTROL  HEATING, VENTILATION AND  AIR CONDITIONING  SYSTEM
Specifications . . . . . . . . . . . . . . . . . . . . . . . .  7D-1 Specifications . . . . . . . . .

Page 1161 of 1574

SSANGYONG MUSSO 2003  Service Manual FATC-HAVC  7D-5
FATC BLOCK DIAGRAM
INCAR SENSOR
AMBIENT SENSOR
WATER TEMPERATURE SENSOR
SUN LOAD SENSOR
TEMPERATURE SWITCH
BLOWER SWITCH
MODE SWITCH
DEFROSTER SWITCH
INTAKE SWITCH
AUTO SWITCH
A/CON SW

Page 1163 of 1574

SSANGYONG MUSSO 2003  Service Manual FATC-HAVC  7D-7
FUNCTION DESCRIPTION 1. AUTO switch 
�By pressing the AUTO switch, set temperature, AUTO, fan speed, air source, air flow mode will be 
appeared on the VFD display.
� Following items w

Page 1164 of 1574

SSANGYONG MUSSO 2003  Service Manual 7D-8  FATC-HAVC Self-diagnosis Method
Ignition switch “ON ”
Press the intake switch more than 4 times within
2 seconds while pressing the AUTO switch
Self-diagnosis will start after turning off al

Page 1165 of 1574

SSANGYONG MUSSO 2003  Service Manual FATC-HAVC  7D-9
Diagnosis Item and Fault Code Self-diagnosis Display 
1. Data will be displayed at the set temperature display as 2-digit number during self-diagnosis function and other settemperature