Page 100 of 2100

1A±74
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Control Panel Switch Operation
Switch NamePanel DisplaySwitch Operation
A
u
t
o
S
w
i
t
c
hDuring manual outside air intake (FRESH), pressing the AUTO
switch cancels manual outside air intake. The display panel shows
the current set temperature, the current air outlet(s), and the blower
speed. The intake switch LED shows the current air source. The
A/C switch LED is on.
Air volume, air outlet operation, and air source are controlled
automatically. The compressor is on.
During manual inside air recirculation (REC), pressing the AUTO
switch does not cancel inside air recirculation. The intake switch
LED is on.
O
f
f
S
w
i
t
c
hWhen the OFF switch is pressed, the display panel clears except
for the air outlet indication. Blower and compressor operation stop.
The air source switches from automatic to outside air.
During manual inside air recirculation (REC), pressing the OFF
switch does not cancel inside air recirculation. The intake switch
LED is on.
F
a
n
´
S
w
i
t
c
h
When the fan switch is pressed, air outlet volume (fan speed) can
be manually controlled. Other control switches are unaffected. The
display panel clears AUTO indication.
1. FAN switch is pressed during automatic fan control (AUTO)
Fan control (AUTO)"Press fan switch"Fan speed increases
from automatic set speed to HI
Fan control (AUTO)"Press fan switch"Fan speed decreases
from automatic set speed to LO
2. Fan switch is pressed when the fan is off.
Fan (OFF)"Press fan switch"The fan operates at LO speed
Fan (OFF)"Press fan switch"The fan operates at LO speed
3. Fan switch is pressed when the fan is in manual operation.
Manual (LO)"Press fan switch"Manual operation
(LO)" (M1)"(M2)"(M3)"(HI)
Manual (HI)"Press fan switch"Manual operation
(HI)"(M3)"(M2)"(M1)"(LO)
M
o
d
e
S
w
i
t
c
hPress the mode switch to manually select the air outlet(s). Each
time the switch is pressed, the air outlets change in the progression
shown below.
Mode switch (Automatic control of air
outlets)"VENT"BI-LEVEL"FOOT"DEF/FOOT
Page 101 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±75
A
/
C
´
S
w
i
t
c
hWhen the A/C switch is pressed, the LED light goes out and the
compressor turns off. If the switch is pressed again, the LED light
turns on and the compressor begins to operate.
The air conditioner will not operate if the fan switch is off.
During manual DEF or D/F operation, the A/C LED will turn on or off
in response to switch operation. However, the compressor remains
on regardless of switch position.
D
E
F
M
o
d
e
S
w
i
t
c
hWhen the defrost switch (DEF) is pressed, air flows from the de-
froster outlets. The compressor is on and blower speed is automati-
cally controlled. Air intake is from outside the vehicle (FRESH). The
defroster symbol appears on the display.
When the defrost switch (DEF) is pressed again, the unit returns to
the settings in use before the defroster was turned on.
Page 102 of 2100
1A±76
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
I
Pressing the intake switch permits manual control of air intake and/
or recirculation.
I
n
t
a
k
e
S
w
i
t
c
h
If the intake switch is pressed during manual DEF or D/F, the intake
switch LED briefly turns on. However, outside air intake (FRESH)
continues.
T
e
m
p
e
r
a
t
u
r
e
C
o
n
t
r
o
l
S
w
i
t
c
hThe display panel temperature setting can be set from 18C (65F)
to 32C (90F).
Pressing and immediately releasing the switch increases the
temperature setting in -17C (1F) increments. If the switch is
pressed and held, the temperature setting increases rapidly.
Pressing and immediately releasing the switch decreases the
temperature setting in -17C (1F) decrements. If the switch is
pressed and held, the temperature setting decreases rapidly.
When the temperature setting is at 32C (90F), the unit is set to
maximum heat mode.
When the temperature setting is at 18C (65F), the unit is set to
maximum cooling mode.
Page 103 of 2100

HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±77
Overview of Construction, Movement
and Control of Major Parts of
Automatic Air Conditioner System
Automatic Air Conditioner Control Unit
Equipped with the built-in micro-computer, this control
unit operates on signals from sensors and input signals
from switches to offer total control of the blower fan, and
actuators used for the mode door, intake door and air mix
door.
Its self-diagnosis function enables quicker access to a
failed part and its more accurate troubleshooting.
In Car Sensor
It is a sensor used for detecting room temperature of a
vehicle. This sensor converts a given room temperature
into a resistance value before entering the data to the
automatic air conditioner control unit.
This in car sensor unites the power driven aspirator and
the motor fan so that a small amount of room air may be
constantly fed to the sensor.
This sensor is provided on the right side of meter cluster.
865R200001
Legend
(1) Meter Cluster
(2) In Car Sensor
Ambient Sensor
This sensor is used for detecting temperature outside the
vehicle. It converts a given outside air temperature into a
resistance value before entering the data to the automatic
air conditioner control unit.
Thermal effects from the condenser and radiator during
idling after a run can be measured and offset the
automatic amplifier.
This sensor is provided on the side plate situated at upper
right side of the condenser.
875R200017
Legend
(1) Ambient Sensor
(2) Condenser Assembly
Duct Sensor
The duct sensor is the sensor to detect temperature
change of the side of evaporator blower coming by fresh
recirculation of intake door or ªonº ªoffº of compressor.
The temperature is converted to resistant rate.
And it works as thermostat to control to prevent freezing
of evaporator.
This sensor is installed in the upper case of evaporator.
874R200001
Legend
(1) Sensor Part
(2) Duct Sensor Assembly
(3) Evaporator Assembly
Page 104 of 2100

1A±78
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Sun Sensor
It is a photodiode used for detecting quantity of solar
radiation. This sensor converts the offset signal
generated by changes in the interior temperature (which
results from fluctuations in solar radiation) into
photoelectric current to enter into the automatic air
conditioner control unit.
This sensor is provided at top of the center cluster upper.
865R200002
Legend
(1) Sun Sensor
(2) Center Cluster Upper
Power Transistor
Receiving base current from the automatic air conditioner
control unit, the power transistor implements stage-less
speed change of the blower fan motor. This transistor is
provided on the evaporator.
874R200009
Legend
(1) Evaporator Assembly
(2) Power Transistor
Max Hi Relay
This relay turned on or off by the signal from the automatic
air conditioner control unit. As the Max Hi relay is turned
on, supply voltage is directly fed to the blower fan motor to
select the Max Hi mode.
873RY00005
Legend
(1) Blower Unit
(2) Max High Relay
Page 105 of 2100

HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±79
Actuator
The actuators are power driven type containing a small
motor. Receiving output current from the automatic air
conditioner control unit, actuators drive the heater and
blower unit mode doors.
Actuators consist of the mode actuator used for switching
the mode (blow port selection), the mix actuator used for
changing aperture of the air mix door, the intake actuator
used for switching the intake mode(fresh air/interior air)
actuator.
860R200004
Legend
(1) Mix Actuator
(2) Intake Actuator
(3) Blower Unit
(4) Mode Actuator
(5) Heater Unit
The actuator changes the motor speed using the gear
and drives each door rotating the output axis united with
the sliding contact.
860RW026
Legend
(1) Output Axis
(2) Motor
(3) Printed Circuit Board
(4) Sliding Contact
The mode and mix actuators are common actuators with
the built-in potentiometer. For the intake actuator, the
contact switch type is selected.
The potentiometer is a register assembled to the printed
circuit board of the mix and mode actuators. It detects the
air mix door position specified by rotation of the output
axis as a ratio of the variable terminal (VM) voltage
against the reference voltage (VDD: 5V), then signals the
value to the automatic air conditioner control unit.
C01RX016
Page 106 of 2100

1A±80
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Movement of Mix Actuator
Position of the air mix door is determined by the controller
on the automatic air conditioner control unit.
As the heat or cool side of the controller is grounded, the
transistor on the driver is activated and, thus, the motor
rotation is turned on. The sliding contact connected to the
motor sends the position detection signal from the
potentiometer to the automatic air conditioner control
unit. As the set temperature and interior temperature are
balanced, the controller returns to the neutral and the
motor rotation is stopped.
C-43
Rotation
direction
Remarks
(+) side(-) sidedirection
86ClockwiseFull heat side
68Counter
clockwiseFull cool side
C01RX005
Movement of Mode Actuator
As target position of the mode door is decided on the
controller of the control unit, the control unit reads the
position detection signal from the actuator to select the
clockwise or counter clockwise motor rotation direction.
Grounding the controller VENT or DEF side after the
direction selection activates the transistor on the driver,
thus turning on the motor rotation. Accompanying the
motor rotation, the sliding contact rotates, too. When the
target position is reached, the controller on the control
unit returns to the neutral and the motor stops.
Conduction pin
Rotation
direction
Remarks
(+) side(-) sidedirection
51ClockwiseVENT to DEF
direction
15Counter
clockwiseDEF to VENT
direction
C01RX017
Page 107 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±81
Movement of Intake Actuator
The controller on the automatic heater/air conditioner
control unit selects an intake mode to be used.
As the Terminal No.5 C-33 is grounded via the sliding
contact on the terminal plate, the transistor on the driver is
activated, thus turning on the motor rotation. Then,
accompanying move of the motor, the sliding contact
rotates until grounding of the Terminal No.5 C-33 is
removed, thus stopping the motor.
Grounding
terminal
Rotation
directionRemarks
No.5 C-33ClockwiseRE-CIRCULATI
ON"MIX"
FRESH
C01RX006
Overview of Automatic Control of
Automatic Air Conditioner
The automatic air conditioner on this vehicle has the
following features:
Interior temperature control.
Air flow control.
Mode (blow port) control.
Intake (switching between fresh air and interior air)
control.
Heater start timing control.
Cooler start timing control.
Evaporator anti-freeze control.