ISUZU AXIOM 2002  Service Repair Manual 1A±50
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
11. Disconnect discharge line (High-pressure hose)
using a back-up wrench.
Use a backup wrench when disconnecting and
reconnecting the refriger

Page 77 of 2100

ISUZU AXIOM 2002  Service Repair Manual HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±51
Main Data And Specifications
General Specifications
Heater Unit
Temperature controlReheat air mix system
Capacity4.3 kw (3700 Kcal./hr.)
Air flo

Page 78 of 2100

ISUZU AXIOM 2002  Service Repair Manual 1A±52
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Torque Specifications
852R200009
874R200013

Page 79 of 2100

ISUZU AXIOM 2002  Service Repair Manual HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±53
Compressor
Service Precaution
WARNING: THIS VEHICLE HAS A SUPPLEMENTAL
RESTRAINT SYSTEM (SRS). REFER TO THE SRS
COMPONENT LOCATION VIEW IN ORDER

Page 80 of 2100

ISUZU AXIOM 2002  Service Repair Manual 1A±54
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Diagnosis
ConditionPossible causeCorrection
Noise from compressionDefective rotor/pistonReplace compressor/cylinder and
shaft assembly
Defective

Page 81 of 2100

ISUZU AXIOM 2002  Service Repair Manual HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±55
Magnetic Clutch Assembly (DKV-14G Type)
Parts Location View
871RX025
Legend
(1) Drive Plate bolt
(2) Drive Plate
(3) Snap Ring(4) Pulley Assembl

Page 82 of 2100

ISUZU AXIOM 2002  Service Repair Manual 1A±56
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
4. Remove snap ring (1) by using snap ring pliers.
871RY00029
5. Remove pulley assembly by using pulley puller pilot
J-38424 (2), pulley puller

Page 83 of 2100

ISUZU AXIOM 2002  Service Repair Manual HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±57
Inspection and Repair
Drive Plate
If the frictional surface shows signs of damage due to
excessive heat, the drive plate and pulley should be
re