Page 116 of 2100
1A±90
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Check of Auto Function
NoItemProcedureCriteriaNo.ItemConditionOperationCriteria
AUTO display highlighted on
display panel.
Cold air discharge.
Set temperature to
18C (65F)
VENT mode.
18C (65F).Intake switch LED on.
Fan speed bar graph display at
MAX6dash;HI
A/C switch LED on.
1Automatic operationAuto-switch ON
Gradually increase
the temperature
setting from 18C
(65F) to 31.5C
(89F).
Temperature of air discharge
increases with increase in setting
temperature.
Air discharge volume changes.
Panel display shows VENT,
BI±LEVEL, FOOT, or DEF/FOOT.
Hot air discharge.
A/C bar graph display disappears.
Set temperature to
32C (90F)
Foot mode.
32C (90F).Intake LED switch off.
Fan speed bar graph display at
MAX-HI
A/C switch LED on.
Page 117 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±91
Troubleshooting With Self-Diagnosis Function
Overview of Self-Diagnosis Function
Sensors (input) and actuators (output) are used to check
circuit function and provide essential data on these
circuits. For more detailed information, refer to the
[Inspection and Repair] Sections for the applicable
system or component.
The Table below shows how to turn the self-diagnosis
function on and off.
Self-Diagnosis Operation Procedure
865R200033
Page 118 of 2100

1A±92
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
StepActionValue(s)Ye sNo
11. Allow the engine to idle until it completely warms up.
2. Turn the starter switch to the OFF position.
3. Place a 60±watt lamp approximately 15 cm from the
sun sensor.
NOTE: This procedure is best performed at night or in
a dark, unlit area.
Is the action complete?
ÐGo to Step 2Ð
2Simultaneously press and hold the RESET key and the
CLOCK key (display unit).
Move the starter switch to start the engine.
Does DIAG appear on the display?
ÐGo to Step 3
Replace
display unit
3Press the COMPUTER MODE key.
Does DIAG AIRCON appear on the display?
ÐGo to Step 4
Replace
audio unit
4NOTE: A '1' should appear in the set temperature
segment of the display.
Does '0' appear in the outside air segment of the
display?
ÐGo to Step 6Go to Step 5
5Repair or replace damaged parts.
NOTE: Refer to
Step 1 Trouble Code Table.
Is the action complete?ÐGo to Step 1Ð
6Press and release the fan switch (one time only).
NOTE: A '2' should appear in the set temperature
segment of the display.
Does '0' appear in the outside air segment of the
display?
ÐGo to Step 8Go to Step 7
7Repair or replace damaged parts.
NOTE: Refer to
Step 2 Trouble Code Table.
Is the action complete?ÐGo to Step 1Ð
8Press and release the fan switch (one time only).
NOTE:
Refer to
Step 3 Sensor Output Check for a sample
output value.
A '3' should appear in the set temperature
segment of the display.
Does the correct sensor output value appear in the
outside air segment of the display?
ÐGo to Step 10Go to Step 9
9Repair or replace damaged parts.
NOTE: Refer to
Trouble Spot Inspection.
Is the action complete?ÐGo to Step 1Ð
10Press and release the fan switch one time only.
NOTE: Refer to
Step 4 (Operation Check) for display
readings and inspection steps.
Are all parts operating normally?
ÐGo to Step 12Go to Step 11
Page 119 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±93
StepNo Ye s Value(s) Action
11Repair or replace damaged parts.
NOTE: Refer to
Trouble Spot Inspection.
Is the action complete?ÐGo to Step 1Ð
121. Press and release the fan switch (one time only).
2. Press the DEF switch several times.
NOTE: A '3' should appear in the set temperature
segment of the display.
Does the correct sequence pattern (1, 2, 1, 2) appear in
the outside air segment of the display?
ÐGo to Step 15Go to Step 13
13Perform diagnosis for DEF switch, intake actuator, and
AUTO A/C control unit.
Have the diagnosis procedures been completed.
ÐGo to Step 14Ð
141. Press and release the fan switch (one time only).
2. Press the DEF switch several times.
Are all parts operating normally?
ÐGo to Step 15
Replace
display unit
15Turn the starter switch OFF.
Is the action complete?
ÐÐÐ
Page 120 of 2100
1A±94
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
STEP 1: Trouble Code Table
Trouble
CodeDefective PartTrouble
CodeDefective Part
1In Car Sensor Open Circuit± 1In Car Sensor Short Circuit
2Ambient Sensor Open Circuit± 2Ambient Sensor Short Circuit
3Sun Sensor Open Circuit± 3Sun Sensor Short Circuit
4Duct Sensor Open Circuit± 4Duct Sensor Short Circuit
5Mix Potentiometer Open Circuit± 5Mix Potentiometer Short Circuit
6Mode Encoder Open Circuit
7Intake Encoder Open Circuit
0No Defective Part
STEP 2: Trouble Code Table
Trouble
CodeDefective PartTrouble
CodeDefective Part
1In Car Sensor Open Circuit± 1In Car Sensor Short Circuit
2Ambient Sensor Open Circuit± 2Ambient Sensor Short Circuit
3Not Used± 3Sun Sensor Short Circuit
4Duct Sensor Open Circuit± 4Duct Sensor Short Circuit
5Mix Potentiometer Open Circuit± 5Mix Potentiometer Short Circuit
6Mode Encoder Open Circuit
7Intake Encoder Open Circuit
0No Defective Part
Page 121 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±95
STEP 3: Sensor Output Check
865R200035
Page 122 of 2100
1A±96
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
STEP 4: Operation Check
865R200032
Page 123 of 2100
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±97
Inspection By Failed Location
Inspection of the Sensors
When the self-diagnosis function has determined that
trouble is present on the sensors, check them according
to the following flow chart.
F01RY00005