EC-168
[QR25(WITH EURO-OBD)]
DTC P0132 HO2S1
CAUTION:
●Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
●Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 92 (HO2S1 signal) and engine ground.
3. Check the following with engine speed held at 2,000 rpm con-
stant under no load.
●The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
●The maximum voltage is over 0.6V at least one time.
●The minimum voltage is below 0.3V at least one time.
●The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V
CAUTION:
●Discard any heated oxygen sensor which has been
dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor;
use a new one.
●Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and InstallationEBS00M3H
HEATED OXYGEN SENSOR 1
Refer to EM-24, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
SEF648Y
PBIB0543E
DTC P0133 HO2S1
EC-169
[QR25(WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC P0133 HO2S1PFP:22690
Component DescriptionEBS00M3I
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1V to 0V.
CONSULT-II Reference Value in Data Monitor ModeEBS00M3J
Specification data are reference values.
ECM Terminals and Reference ValueEBS00M3K
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpmLEAN←→ RICH
Changes more than 5 times dur-
ing 10 seconds.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
92 G/WHeated oxygen sen-
sor 1[Engine is running]
●Warm-up condition
●Engine speed is 2,000 rpm.0 - Approximately 1.0V (Periodi-
cally change)
DTC P0133 HO2S1
EC-171
[QR25(WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 20 to 50 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-173, "
Diagnostic
Procedure" .
Overall Function CheckEBS00M3N
Use this procedure to check the overall function of the heated oxygen sensor 1 circuit. During this check, a
DTC might not be confirmed.
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 92 (HO2S1 signal) and engine ground.
3. Check the following with engine speed held at 2,000 rpm con-
stant under no load.
–The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V more
than 5 times within 10 seconds.
4. If NG, go to EC-173, "
Diagnostic Procedure" .
ENG SPEED 1,650 - 3,600 rpm
Vehicle speed More than 80 km/h (50 MPH)
B/FUEL SCHDL 4.0 - 14.5msec
Selector lever Suitable position
SEF339Z
SEF658Y
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2
times:0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V
→ 0 - 0.3V
PBIB0543E
EC-176
[QR25(WITH EURO-OBD)]
DTC P0133 HO2S1
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the follow-
ing steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
●“HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes
from “RICH” to “LEAN” to “RICH” 5 times in 10 seconds.
5 times (cycles) are counted as shown at right.
●“HO2S1 (B1)” voltage goes above 0.6V at least once.
●“HO2S1 (B1)” voltage goes below 0.3V at least once.
●“HO2S1 (B1)” voltage never exceeds 1.0V.
CAUTION:
●Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
●Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 92 (HO2S1 signal) and engine ground.
3. Check the following with engine speed held at 2,000 rpm con-
stant under no load.
●The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
●The maximum voltage is over 0.6V at least one time.
●The minimum voltage is below 0.3V at least one time.
●The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V
SEF646Y
SEF217YA
SEF648Y
PBIB0543E
DTC P0133 HO2S1
EC-177
[QR25(WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
CAUTION:
●Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
●Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and InstallationEBS00M3R
HEATED OXYGEN SENSOR 1
Refer to EM-24, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
EC-178
[QR25(WITH EURO-OBD)]
DTC P0134 HO2S1
DTC P0134 HO2S1
PFP:22690
Component DescriptionEBS00M3S
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1V to 0V.
CONSULT-II Reference Value in Data Monitor ModeEBS00M3T
Specification data are reference values.
ECM Terminals and Reference ValueEBS00M3U
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V ←→ Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
●Engine: After warming upMaintaining engine speed at 2,000
rpmLEAN ←→ RICH
Changes more than 5 times dur-
ing 10 seconds.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
92 G/WHeated oxygen sen-
sor 1[Engine is running]
●Warm-up condition
●Engine speed is 2,000 rpm.0 - Approximately 1.0V (Periodi-
cally change)
DTC P0134 HO2S1
EC-179
[QR25(WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
On Board Diagnosis LogicEBS00M3V
Under the condition in which the heated oxygen sensor 1 signal is
not input, the ECM circuits will read a continuous approximately
0.3V. Therefore, for this diagnosis, the time that output voltage is
within 200 to 400 mV range is monitored, and the diagnosis checks
that this time is not inordinately long.
DTC Confirmation ProcedureEBS00M3W
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “HO2S1 (B1) P0134” of “HO2S1” in “DTC WORK SUPPORT” mode with CONSULT-II.
3. Touch “START”.
4. Let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 4.
5. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 10 to 60 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
SEF237U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0134
0134Heated oxygen sensor
1 circuit high no activity
detectedThe voltage from the sensor is constantly
approx. 0.3V.
●Harness or connectors
(The sensor circuit is open or shorted)
●Heated oxygen sensor 1
PBIB0544E
ENG SPEED 1,550 - 3,600 rpm
Vehicle speed More than 64 km/h (40 MPH)
B/FUEL SCHDL 2.9 - 14.5 msec
Selector lever Suitable position
PBIB0545E
DTC P0134 HO2S1
EC-183
[QR25(WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
5.CHECK INTERMITTENT INCIDENT
Refer to EC-115, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS00M40
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the follow-
ing steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
●“HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes
from “RICH” to “LEAN” to “RICH” 5 times in 10 seconds.
5 times (cycles) are counted as shown at right.
●“HO2S1 (B1)” voltage goes above 0.6V at least once.
●“HO2S1 (B1)” voltage goes below 0.3V at least once.
●“HO2S1 (B1)” voltage never exceeds 1.0V.
CAUTION:
●Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
●Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 92 (HO2S1 signal) and engine ground.
SEF646Y
SEF217YA
SEF648Y