Page 1768 of 2898
DIAGNOSTIC PROCEDURE 1 (LIGHTING SWITCH
INPUT SIGNAL CHECK)
=NJEL0455S03
1 CHECK LIGHTING SWITCH INPUT SIGNAL
Check voltage between time control unit terminal 10 and ground.
SEL449X
OK or NG
OK©Lighting switch is OK.
NG©Check the following.
+10A fuse (No. 38, located in the fuse and fusible link box)
+Harness for open or short between time control unit and lighting switch/daytime light
control unit
+Lighting switch
WARNING CHIME
Trouble Diagnoses/Hatchback (Cont'd)
EL-210
Page 1769 of 2898
DIAGNOSTIC PROCEDURE 2 (KEY SWITCH INSERT
SIGNAL CHECK)
=NJEL0455S04
1 CHECK KEY SWITCH INPUT SIGNAL
Check voltage between time control unit terminal 22 and ground.
SEL433X
OK or NG
OK©Key switch is OK.
NG©GO TO 2.
2 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
YEL786C
OK or NG
OK©Check the following.
+10A fuse [No. 12, located in fuse block (J/B)]
+Harness for open or short between key switch and fuse
+Harness for open or short between time control unit and key switch
NG©Replace key switch.
WARNING CHIME
Trouble Diagnoses/Hatchback (Cont'd)
EL-211
Page 1770 of 2898
DIAGNOSTIC PROCEDURE 3 (DOOR UNLOCK SENSOR
CHECK)
NJEL0455S05
1 CHECK DOOR UNLOCK SENSOR INPUT SIGNAL
Check voltage between time control unit terminal 35 and ground.
SEL431X
OK or NG
OK©Door unlock sensor is OK.
NG©GO TO 2.
2 CHECK DOOR UNLOCK SENSOR
1. Disconnect door unlock sensor connector.
2. Check continuity between door unlock sensor terminals 2 and 5.
SEL988W
OK or NG
OK©Check the following.
+Door unlock sensor ground circuit
+Harness for open or short between time control unit and door unlock sensor
NG©Replace door unlock sensor.
WARNING CHIME
Trouble Diagnoses/Hatchback (Cont'd)
EL-212
Page 1771 of 2898
DIAGNOSTIC PROCEDURE 4NJEL0455S06
1 CHECK IGNITION ON SIGNAL
Check voltage between time control unit terminal 1 or 9 and ground.
SEL447X
OK or NG
OK©GO TO 2.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+15A fuse [No. 5, located in the fuse block (J/B)]
+Harness for open or short between time control unit and fuse
2 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between time control unit terminal 6 and ground.
SEL430X
OK or NG
OK©System is OK.
NG©Check voltage between time control unit terminal 6 and body ground with disconnecting
front door switch (driver side).
If approx. 5V is supplied, GO TO 3.
If approx. 5V is not supplied, replace time control unit.
WARNING CHIME
Trouble Diagnoses/Hatchback (Cont'd)
EL-213
Page 1772 of 2898
3 CHECK DRIVER SIDE DOOR SWITCH
Check continuity between terminals 2 and 3.
SEL325WA
OK or NG
OK©Check the following.
+Driver side door switch ground circuit and condition
+Harness for open or short between time control unit and driver side door switch
NG©Replace driver side door switch.
WARNING CHIME
Trouble Diagnoses/Hatchback (Cont'd)
EL-214
Page 1950 of 2898

System Description/Sedan=NJEL0399FUNCTIONNJEL0399S01Multi-remote control system has the following function.
+Door lock (and set super lock)
+Door unlock (and release super lock)
+Hazard reminder
LOCK OPERATIONNJEL0399S02To lock door by multi-remote controller, the ignition switch must be at OFF.
When the LOCK signal is input to multi-remote control unit (the antenna of the system is combined with multi-
remote control unit), ground is supplied
+through multi-remote control unit terminal 5
+to time control unit terminal 32.
Then time control unit operates to lock doors and set super lock (models with super lock).
UNLOCK OPERATIONNJEL0399S03When the UNLOCK signal is input to multi-remote control unit (the antenna of the system is combined with
multi-remote control unit), ground is supplied
+through multi-remote control unit terminal 6
+to time control unit terminal 33.
Time control unit operates to unlock driver's door and release super lock (models with super lock).
Then, if an unlock signal is sent from the remote controller again within 5 seconds, all other doors will be
unlocked.
HAZARD REMINDERNJEL0399S04When the doors are locked or unlocked by multi-remote controller (signal from driver side unlock sensor),
supply power to hazard warning lamp flashes as follows
+Lock operation: Flash once
+Unlock operation: Flash twice
MULTI-REMOTE CONTROLLER ID CODE ENTRYNJEL0399S05A maximum of four remote controllers can be entered.
To enter ID code entry, the following signals must be input to the multi-remote control unit.
+Ignition switch (ON)
+Signal from remote controller
For detailed procedure, refer to ªID Code Entry Procedureº in EL-402.
MULTI-REMOTE CONTROL SYSTEM
System Description/Sedan
EL-392
Page 1958 of 2898
HAZARD REMINDER CHECK=NJEL0478S04
1 CHECK HAZARD WARNING LAMP
Check if hazard warning lamp flashes with hazard switch.
Does hazard warning lamp operate?
Ye s©GO TO 2.
No©Check hazard warning lamp circuit.
2 CHECK HAZARD REMINDER OPERATION
Check the following at when push the multi-remote control switch.
Check voltage between terminal 3 and ground.
Check voltage between terminal 8 and ground.
SEL502X
OK or NG
OK©GO TO 3.
NG©Replace multi-remote control unit.
3 CHECK HAZARD REMINDER CIRCUIT
1. Disconnect multi-remote control unit harness connector.
2. Check continuity between multi-remote control unit and hazard switch.
SEL503X
OK or NG
OK©System is OK.
NG©Repair harness.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses/Sedan (Cont'd)
EL-400
Page 1968 of 2898

IGNITION ªONº POWER SUPPLY CIRCUIT FOR TIME
CONTROL UNIT
=NJEL0482S17
1 CHECK IGNITION ªONº POWER SUPPLY CIRCUIT FOR TIME CONTROL UNIT
1. Disconnected time control unit harness connector.
2. Check voltage between time control unit terminal 1 and ground.
SEL429X
OK or NG
OK©Ignition ªONº power supply circuit is OK.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+Harness for open or short between time control unit and fuse.
HAZARD REMINDER CHECKNJEL0482S18
1 CHECK HAZARD WARNING LAMP
Check if hazard warning lamp flashes with hazard switch.
Does hazard warning lamp operate?
Ye s©GO TO 2.
No©Check hazard warning lamp circuit.
2 CHECK HAZARD REMINDER OPERATION
Check the following at when push the multi-remote control switch.
Check voltage between terminal 11 and ground.
Check voltage between terminal 15 and ground.
SEL499X
OK or NG
OK©System is OK.
NG©Replace time control unit. (Before replacing the unit, make sure the remote controller ID
registration for time control unit and the remote controller battery once again.)
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses/Hatchback (Cont'd)
EL-410