Trouble diagnosis of turbocharger
Preliminary check:
Check that the VNT control valve system has no malfunction.
Refer to EC section, ªECM Terminals and Reference Valueº in
ªTROUBLE DIAGNOSIS Ð GENERAL DESCRIPTIONº.
+Check that the engine oil level is between MIN and MAX of
the dipstick. (When the engine oil amount is more than MAX,
the oil flows into the inlet duct through the blow-by gas
passage, and the turbocharger is misjudged failure.)
+Ask the customer if he/she always runs the vehicle in idle
engine speed to cool the oil down after driving.
+Replace the turbocharger assembly when any malfunction is
found after unit inspections specified in the table below.
+If no malfunction is found after the unit inspections, judge that
the turbocharger body has no failure. Check the other parts
again.
Inspection item Inspection resultSymptom (when each inspection item
meets each inspection result)
Oil leak-
ageSmoke NoiseInsuffi-
cient
power/
accel-
eration
failure
Turbine wheelOil leaks.n
nn
Carbon is accumulated.n
jj
Friction with housing.nj
j
Blades are bent or broken.
Compressor wheelInside the air inlet is seriously contami-
nated by oil.jj
Friction with housing.njj
Blades are bent or broken.
After checking both turbine and compressor,
inspect rotor shaft end play.There is resistance when the rotor shaft
is rotated by your fingertips.nnj
The rotor shaft sometimes does not
rotate by your fingertips.
There is too much play in the bearing.nnjn
Oil return portCarbon or sludge is accumulated in the
waste oil hole.n
nn
Operation of VNT control actuator+The actuator does not operate
smoothly when vacuum pressure is
gradually applied.
+Stroke amount is not in compliance
with the vacuum pressure.j
: Large possibility
j: Medium possibility
n: Small possibility
INSTALLATION
1. Install catalyst.
:29-39Nzm (2.9 - 3.3 kg-m, 21 - 23 ft-lb)
Place the protruding area of the gasket between the turbo-
charger and the exhaust outlet upwards, and install the lipped
side to the turbocharger side. Refer to the figure, EM-1014.
2. Install in the reverse order of removal.
CATALYST AND TURBOCHARGERZD
Inspection (Cont'd)
EM-1017
3. Drain oil and fill with new engine oil.
Oil grade: API CF4 or ACEA B3-96.98 or ACEA B3/E3-
96.98
Viscosity:
See ªRECOMMENDED FLUIDS AND
LUBRICANTSº, MA-1009.
Refill oil capacity (approximate):
Without oil filter change
5.2!(4-5/8 Imp qt)
With oil filter change
5.7!(5 Imp qt)
CAUTION:
+Be sure to clean and install oil pan drain plug with
washer.
Drain plug:
:54-58Nzm (5.5 - 6.0 kg-m, 40 - 43 ft-lb)
+The refill capacity changes depending on the oil tem-
perature and drain time; use these valves as a reference
and be certain to check with the dipstick when changing
the oil.
4. Check oil level.
5. Start engine. Check area around drain plug and oil filter for
any sign of oil leakage.
6. Run engine for a few minutes, then turn it off. After 10 min-
utes check oil level.
Changing Engine Oil Filter
REMOVAL
1. Insert a suitable tool with a 12.7 mm square (1/2 inch square)
such as an extension bar and ratchet handle into the filter
body, and loosen the body by approximately 4 turns.
WARNING:
Be careful not to burn yourself, as the engine and engine oil
are hot.
SMA102D
JMA103D
JMA104D
ENGINE MAINTENANCEZD
Changing Engine Oil (Cont'd)
MA-1013