HEATER, AIR CONDITIONER AND VENTILATION -Troubleshooting 55B-19
Termi-
nal No.Normal condition Check conditions Check item
15Rear defoggerRear defogger: OFFSystem voltage
Rear defogger: ON1.5 V or less
16Multi center display unit communication
lineIgnition switch: ONHi: 4 - 5 V
Lo: 0 - 1 V
17Multi center display unit communication
lineIgnition switch: ONHi: 4 - 5 V
Lo: 0 - 1 V
18Multi center display unit communication
line shieldAt all times0V
19Diagnosis outputIgnition switch: ONA voltmeter needle
fluctuates between 0
and 12 V.
20Input from A/C compressor relayWhen the A/C is off.0V
When the A/C is in operation
(When compressor is operating)System voltage
21Power supply to potentiometerAt all times5V
22Input from outside air temperature
sensorSensor temperature: 25
_C (1.7 kW)1.9 V
23Input from heater water temperature
sensorSensor temperature: 25
_C(5kW)2.8 V
24Input from potentiometer for air mix
damperWhen the damper flap is moving to the
MAX HOT position.0.7 - 1.3 V
25Power supply to illuminationLighting switch: ONSystem voltage
26Power supply to ignition switch (IG2)Ignition switch: ONSystem voltage
27Power supply to ignition switch (ACC)Ignition switch: ACCSystem voltage
28Backup power supplyAt all timesSystem voltage
29Earth to sensor and potentiometerAt all times0V
30Input from air thermo sensorSensor temperature: 25
_C (1.5 kW)2.2 V
31Photo sensor (+)During 800 kcal/m2-h1V
32Input from potentiometer for the air
outlet changeover damperWhen the damper flap is moving to the
DEF position.0.7 - 1.3 V
33Diagnosis inputIgnition switch: ON0V
34Compressor lock signal (ignition signal)Engine speed: 3 000 r/min0.3 - 3.0
35Illumination earthAt all timesContinuity
36EarthAt all timesContinuity
CHECK AT ENGINE-A/T-ECU OR ENGINE-ECU TERMINALS
Refer to GROUP 13A – Troubleshooting or GROUP 13B – Troubleshooting .
www.WorkshopManuals.co.uk
Purchased from www.WorkshopManuals.co.uk