1998 JAGUAR X308 Ground

[x] Cancel search: Ground

Page 1375 of 2490

JAGUAR X308 1998 2.G Workshop Manual Automatic Transmission/Transaxle - 4.0L NA V8 - AJ27/3.2L NA V8 - AJ26 
- Transmission 
Removal 
Removal 
Special Tool(s)
 
Engine support 
303-021 
 
Engine lifting brackets 
303-536 
1. Select N gea

Page 1379 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
25. Remove the bolts which secure the engine harness connector 
mounting bracket and move th e bracket aside for access. 
26.  On the RH side, clear the  cooler pipe for access. 
 
27.  NOTE: View

Page 1384 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
5. Fit the transmission to the engine. 
Loosely assemble - Cooler pipe clip.  
Loosely assemble - Ground lead.  
Loosely assemble - Ca talyst brackets.  
1. Tighten in sequence 1, 2, 3, 4

Page 1397 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
Connector Pin Identity Chart for EM062 
 
Connector Pin Identity Chart for CC008 
Pin NumberCircuitCircuit Function
001Not used
002Kickdown SW
003Mode SW
025DLS position WO
026DLS position W1
027DLS

Page 1398 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
Connector Pin Identity Chart for GB001 
 
Connector Pin Identity Chart for EM044 
Pin NumberCircuitCircuit Function
001DLS position W3
002Power ground (common to TCM)
003Ignition B+
004Neutral (BPU)

Page 1399 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
 
Pin NumberCircuitCircuit Function
001n3 speed signal
002Pressure regulator MD signal
003n2 speed signal
004Temperature sensor
005Solenoid 1 <-> 2, 4 <-> 5
006Solenoid and pressure regulator +ve

Page 1407 of 2490

JAGUAR X308 1998 2.G Workshop Manual  With EM062 and GB001 disconnected, measure the 
resistance between EM062/038 and EM061/029 1 
> 10 MOHM? 
Yes GO to C4  
No  Inspect EM062, EM044 and GB001 for corrosion, bent / 
pushed back pins or

Page 1410 of 2490

JAGUAR X308 1998 2.G Workshop Manual With EM062 and GB001 disconnected, measure the 
resistance between EM062/014 and EM061/029 1 
Repeat for EM062/015 and EM061/029 2 
EM062/016 and EM061/029 3 
Is the resistance > 10 MOHM? 
Yes GO to C