1996 TOYOTA TERCEL remove instrument panel

[x] Cancel search: remove instrument panel

Page 183 of 1202

TOYOTA TERCEL 1996  Service Repair Manual P25914P25915A07081
TE1
E1 SST
DLC1
- DIAGNOSTICSENGINE
DI-9
1996 TERCEL   (RM440U)
(e) Remove the fuse cover on the instrument panel.
(f) Connect the OBD II scan tool or TOYOTA hand-held tester to DLC

Page 184 of 1202

TOYOTA TERCEL 1996  Service Repair Manual P25916
S00553
DI-10
- DIAGNOSTICSENGINE
1996 TERCEL   (RM440U)
7 Check fuel pressure.
PREPARATION:
(a) Be sure that enough fuel is in the tank.
(b) Turn ignition switch ON.
(c) Remove the fuse cover o

Page 195 of 1202

TOYOTA TERCEL 1996  Service Repair Manual A15677
- DIAGNOSTICSENGINE
DI-21
1996 TERCEL   (RM440U)
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
If DTC P0105, P0110, P0115, P0120 are output simultaneously, E2 (sensor ground) may be open.
1 Connect

Page 199 of 1202

TOYOTA TERCEL 1996  Service Repair Manual A10940
ECM
E7
E7 L-B
BR5V
R
E1 E2 THA
2
1 Intake Air Temp. Sensor
15
16
- DIAGNOSTICSENGINE
DI-25
1996 TERCEL   (RM440U)
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
If DTC P0105, P0106, P0110, P0115, P0

Page 203 of 1202

TOYOTA TERCEL 1996  Service Repair Manual A15685
- DIAGNOSTICSENGINE
DI-29
1996 TERCEL   (RM440U)
INSPECTION PROCEDURE
HINT:
If DTC P0105, P0106, P0110, P0115, P0120 are output simultaneously, E2 (sensor ground) may be open.
1 Connect OBD II

Page 208 of 1202

TOYOTA TERCEL 1996  Service Repair Manual A15689
FI7052
DI-34
- DIAGNOSTICSENGINE
1996 TERCEL   (RM440U)
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
If DTC P0105, P0110, P0120 are output simultaneously, E2 (sensor ground) may be open.
1 Connect

Page 213 of 1202

TOYOTA TERCEL 1996  Service Repair Manual A15693
- DIAGNOSTICSENGINE
DI-39
1996 TERCEL   (RM440U)
WIRING DIAGRAM
INSPECTION PROCEDURE
1 Connect OBD II scan tool or TOYOTA hand-held tester and read value for volt-
age output of heated oxygen s

Page 216 of 1202

TOYOTA TERCEL 1996  Service Repair Manual DI-42
- DIAGNOSTICSENGINE
1996 TERCEL   (RM440U)
INSPECTION PROCEDURE
1 Check for open and short in harness and connector between ECM and oxygen
sensor (See page IN-26).
NG Repair or replace harness o