I01386
AC-4
- AIR CONDITIONINGAIR CONDITIONING SYSTEM
1996 TERCEL (RM440U)
2. INSPECT REFRIGERANT PRESSURE WITH MAN-
IFOLD GAUGE SET
This is a method in which the trouble is located by using a man-
ifold gauge set. Read the manifold gauge pressure when these
conditions are established.
Test conditions:
Temperature at the air inlet with the switch set
at RECURC is 30 - 35 °C (86 - 95 °F).
Engine running at 1,500 rpm.
Blower speed control switch set at high.
Temperature control set at max. cool.
HINT:
It should be noted that the gauge indications may vary slightly
due to ambient temperature conditions.
(1) Normally functioning refrigeration system.
Gauge reading:
Low pressure side:
0.15 - 0.25 MPa (1.5 - 2.5 kgf/cm
2)
High pressure side:
1.37 - 1.57 MPa (14 - 16 kgf/cm
2)