Page 1001 of 2062
Downloaded from www.Manualslib.com manuals search engine SF1QJ−01
− MFI (3RZ−FE)MASS AIR FLOW (MAF) METER
MF−37
1996 TOYOTA T100 (RM449U)
REMOVAL
1. REMOVE AIR CLEANER CAP AND MAF METER
(a) Disconnect the MAF meter connector, IAT sensor con-
nector and wire clamp.
(b) Loosen the air cleaner hose clamp.
(c) Loosen the 4 clips, and remove the air cleaner cap and
MAF meter.
2. REMOVE MAF METER FROM AIR CLEANER CAP
(a) Remove the 4 nuts, MAF meter and gasket.
(b) Remove the IAT sensor from air cleaner cap.
Page 1002 of 2062
Downloaded from www.Manualslib.com manuals search engine SF1GL−01
P15781
MF−38
− MFI (3RZ−FE)MASS AIR FLOW (MAF) METER
1996 TOYOTA T100 (RM449U)
INSPECTION
INSPECT MAF METER OPERATION
(a) Connect negative (−) terminal cable to battery.
(b) Turn the ignition switch ON.
(c) Connect the MAF meter connector.
(d) Using a voltmeter, connect the positive (+) tester probe to
terminal VG, and negative (−) tester probe to terminal E3.
(e) Blow air into the MAF meter, and check that the voltage
fluctuates.
If operation is not as specified, replace the MAF meter.
(f) Turn the ignition switch OFF.
(g) Disconnect negative (−) terminal cable from battery.
(h) Disconnect the MAF meter connector.
Page 1003 of 2062
Downloaded from www.Manualslib.com manuals search engine SF0AZ−02
− MFI (3RZ−FE)MASS AIR FLOW (MAF) METER
MF−39
1996 TOYOTA T100 (RM449U)
INSTALLATION
1. INSTALL MAF METER TO AIR CLEANER CAP
(a) Install the IAT sensor to the air cleaner cap.
(b) Place a new gasket on the air cleaner cap.
(c) Install the MAF meter with the 4 nuts.
Torque: 8.5 N·m (87 kgf·cm, 75 in.·lbf)
2. INSTALL MAF METER AND AIR CLEANER CAP
Page 1004 of 2062
Downloaded from www.Manualslib.com manuals search engine B02510
SF0BA−03
P07170
Ohmmeter
No
ContinuityContinuity
3Ohmmeter
2 1
5
P07171
Ohmmeter
3
2 1
5
Battery
MF−40
− MFI (3RZ−FE)EFI MAIN RELAY
992 Author: Date:
1996 TOYOTA T100 (RM449U)
EFI MAIN RELAY
INSPECTION
1. REMOVE EFI MAIN RELAY (Marking: EFI)
2. INSPECT EFI MAIN RELAY CONTINUITY
(a) Using an ohmmeter, check that there is continuity be-
tween terminals 1 and 2.
If there is no continuity, replace the relay.
(b) Check that there is no continuity between terminals 3 and
5.
If there is continuity, replace the relay.
3. INSPECT EFI MAIN RELAY OPERATION
(a) Apply battery voltage across terminals 1 and 2.
(b) Using an ohmmeter, check that there is continuity be-
tween terminals 3 and 5.
If there is no continuity, replace the relay.
4. REINSTALL EFI MAIN RELAY
Page 1005 of 2062
Downloaded from www.Manualslib.com manuals search engine SF0BB−02
Z14696
− MFI (3RZ−FE)CIRCUIT OPENING RELAY
MF−41
993 Author: Date:
1996 TOYOTA T100 (RM449U)
CIRCUIT OPENING RELAY
COMPONENTS
Page 1006 of 2062
Downloaded from www.Manualslib.com manuals search engine SF0BC−02
FI1908
FI1909
MF−42
− MFI (3RZ−FE)CIRCUIT OPENING RELAY
1996 TOYOTA T100 (RM449U)
INSPECTION
1. REMOVE GLOVE COMPARTMENT DOOR
2. REMOVE CIRCUIT OPENING RELAY
3. INSPECT CIRCUIT OPENING RELAY CONTINUITY
(a) Using an ohmmeter, check that there is continuity be-
tween terminals STA and E1.
If there is no continuity, replace the relay.
(b) Check that there is continuity between terminals +B and
FC.
If there is no continuity, replace the relay.
(c) Check that there is no continuity between terminals +B
and FP.
If there is continuity, replace the relay.
4. INSPECT CIRCUIT OPENING RELAY OPERATION
(a) Apply battery voltage across terminals STA and E1.
(b) Using an ohmmeter, check that there is continuity be-
tween terminals +B and FP.
If there is no continuity, replace the relay.
5. REINSTALL CIRCUIT OPENING RELAY
6. REINSTALL GLOVE COMPARTMENT DOOR
Page 1007 of 2062
Downloaded from www.Manualslib.com manuals search engine P15774
P15773
SF0BE−01
P15772
P15771
− MFI (3RZ−FE)VSV FOR EVAPORATIVE EMISSION (EVAP)
MF−43
995 Author: Date:
1996 TOYOTA T100 (RM449U)
VSV FOR EVAPORATIVE
EMISSION (EVAP)
INSPECTION
1. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance: 30 − 34 Ω at 20°C (68°F)
If there is no continuity, replace the VSV.
2. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
3. INSPECT VSV OPERATION
(a) Check that air does not flow from pipe E to pipe F.
(b) Apply battery voltage across the terminals.
(c) Check that air flows from pipe E to pipe F.
If operation is not as specified, replace the VSV.
Page 1008 of 2062
Downloaded from www.Manualslib.com manuals search engine P15763
Ohmmeter
Continuity
SF0BD−01
P15764
Ohmmeter
No Continuity
P15765
Air
E
F
P15766
Air
E
F Battery MF−44
− MFI (3RZ−FE)VSV FOR EXHAUST GAS RECIRCULATION (EGR)
SYSTEM
996 Author: Date:
1996 TOYOTA T100 (RM449U)
VSV FOR EXHAUST GAS
RECIRCULATION (EGR)
INSPECTION
1. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the
terminals.
Resistance: 33 − 39 Ω at 20°C (68°F)
If there is no continuity, replace the VSV.
2. INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.
3. INSPECT VSV OPERATION
(a) Check that air does not flow from pipe E to pipe F.
(b) Apply battery voltage across the terminals.
(c) Check that air flows from pipe E to pipe F.
If operation is not as specified, replace the VSV.