P24654
(+)
(−)E21
DI−24
−
DIAGNOSTICS ENGINE
1996 LAND CRUISER (RM451U)
5 Check continuity between terminal E21 of ECM and body ground.
PREPARATION:
Remove instrument panel speaker No.1 panel
(See pageSF−65).
CHECK:
Check continuity between terminal E21 of ECM and body
ground.
OK:
Continuity (1 Ω or less)
NG Check and replace ECM (See page IN−28 ).
OK
6 Check for open in harness and connector between mass air flow meter and \
ECM (See page IN−28 ).
NG Repair or replace harness or connector.
OK
Replace mass air flow meter.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 464 of 1399

A00484
Intake Air Temp. Sensor
(Inside the mass air flow meter)
3
4 L−Y
BR−B 5V
ECM
E5
E5
THA
E1
E2
P22420
3
9 R
−
DIAGNOSTICS ENGINE
DI−27
1996 LAND CRUISER (RM451U)
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
If DTCs P0110 (Intake Air Temp. Circuit Malfunction), P0115 (Engine Coolant Temp. Circuit Malfunction),
P0120 (Throttle/Pedal Position Sensor/Switch ”A” Circuit Malfunction)\
are output simultaneously, E2 (Sen-
sor Ground) may be open.
1 Connect the OBD II scan tool or TOYOTA hand −held tester, and read value of
intake air temperature.
PREPARATION:
(a) Remove the fuse cover on the instrument panel.
(b) Connect the OBD II scan tool or TOYOTA hand−held tester to DLC3.
(c) Turn ignition switch ON and OBD II scan tool or TOYOTA hand−held tester main switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA hand −held tester.
OK:
Same as actual intake air temp.
HINT:
If there is open circuit, push OBD II scan tool or TOYOTA hand− held tester indicates − 40° C (− 40°F).
If there is short circuit, OBD II scan tool or TOYOTA hand held tester indicates 140° C (284°F) or more.
NG − 40° C (− 40 °F) ....Go to step 2.
140 °C (284°F) or more ....Go to step 4.
OK
Check for intermittent problems
(See page DI−3 ).
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 465 of 1399

A00154
ON
Intake Air
Temp. Sensor ECM
5V
E2 E1
3
4 3
9
E5
E5
BE6653
FI7055 A00154 THA
A00150
ON
Intake Air
Temp. Sensor ECM
5V
3
9 E2
E1
THA E2
THA
E5
E5
BE6653
FI7057
P24655
DI−28
−
DIAGNOSTICS ENGINE
1996 LAND CRUISER (RM451U)
2 Check for open in harness or ECM.
PREPARATION:
(a) Disconnect the mass air flow meter connector.
(b) Connect sensor wire harness terminals together.
(c) Turn ignition switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA hand −
held tester.
OK:
Temp. value: 140° C (284°F) or more
OK Confirm good connection at sensor. If OK, replace mass air flow meter.
NG
3 Check for open in harness or ECM.
PREPARATION:
(a) Remove instrument panel speaker No.1 panel (See page SF−65 ).
(b) Connect between terminals THA and E2 of ECM connec-
tor.
HINT:
Mass air flow meter connector is disconnected.
Before checking, do a visual and contact pressure check for the
ECM connector (See page IN−28).
(c) Turn ignition switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA
hand −held tester.
OK:
Temp. value: 140° C (284°F) or more
OK Open in harness between terminals E2 or THA, repair or replace harness.
NG
Confirm good connection at ECM.
If OK, replace ECM (See page IN−28).
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 466 of 1399

A00151
ON
Intake Air
Temp. Sensor 3
4 ECM
3
9 5V
E2 E1
THA
E5
E5
BE6653
FI7054
A00155
ON
Intake Air
Temp. Sensor ECM
E5 connector 5V
E2 E1
THA
BE6653
FI7056
P19798
−
DIAGNOSTICS ENGINE
DI−29
1996 LAND CRUISER (RM451U)
4 Check for short in harness and ECM.
PREPARATION:
(a) Disconnect the mass air flow meter connector.
(b) Turn ignition switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA hand −
held tester.
OK:
Temp. value: − 40° C (− 40°F)
OK Replace mass air flow meter.
NG
5 Check for short in harness or ECM.
PREPARATION:
(a) Remove instrument panel speaker No.1 panel (See page SF−65 ).
(b) Disconnect the E5 connector of ECM.
HINT:
Mass air flow meter connector is disconnected.
(c) Turn ignition switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA hand −
held tester.
OK:
Temp. value: − 40°C (− 40 °F)
OK Repair or replace harness or connector (See page IN−28 ).
NG
Check and replace ECM (See page IN−28 ).
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 468 of 1399

A00156
ON
Engine Coolant
Temp. Sensor ECM
5V
4
9
2
1
E2
E1
THW
E5
E5
BE6653
FI7055
−
DIAGNOSTICS ENGINE
DI−31
1996 LAND CRUISER (RM451U)
INSPECTION PROCEDURE
HINT:
If DTC is P0110 (Intake Air Temp. Circuit Malfunction), P0115 (Engine Coolant Temp. Circuit Malfunction),
P0120 (Throttle/Pedal Position Sensor/Switch ”A” Circuit Malfunction)\
are output simultaneously, E2 (Sen-
sor Ground) may be open.
1 Connect the OBD II scan tool or TOYOTA hand −held tester, and read value of
engine coolant temperature.
PREPARATION:
(a) Remove the fuse cover on the instrument panel.
(b) Connect the OBD II scan tool or TOYOTA hand−held tester to the DLC3.
(c) Turn ignition switch ON and push the OBD II scan tool or TOYOTA hand−held tester main switch ON.
CHECK:
Read temperature value on the OBD II scan tool or TOYOTA hand −held tester.
OK:
Same as actual engine coolant temperature.
HINT:
If there is open circuit, OBD II scan tool or TOYOTA hand−held tester indicates − 40°C (− 40 °F).
If there is short circuit, OBD II scan tool or T OYOTA hand−held tester indicates 140 °C (284 °F) or more.
NG −40°C ( −40° F) ... Go to step 2.
140 °C (284° F) or more ... Go to step 4.
OK
Check for intermittent problems
(See page DI−3 ).
2 Check for open in harness or ECM.
PREPARATION:
(a) Disconnect the engine coolant temp. sensor connector.
(b) Connect sensor wire harness terminals together.
(c) Turn ignition switch ON.
CHECK:
Read temp. value on the OBD II scan tool or TOYOTA hand −
held tester.
OK:
Temp. value: 140° C (284°F) or more
OK Confirm good connection at sensor. If OK, replace engine coolant temp. sensor.
NG
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 469 of 1399

A00157
ONECM
Engine Coolant
Temp. Sensor
5V
E2 E1
2
1
THW E2
THW
E5
E54
9
BE6653
FI7057
P24656
A00158
ON
Engine Coolant
Temp. Sensor ECM
5V
4
9 E2
E1
THW
BE6653
FI7054 E5
E5
DI−32
−
DIAGNOSTICS ENGINE
1996 LAND CRUISER (RM451U)
3 Check for open in harness or ECM.
PREPARATION:
(a) Remove instrument panel speaker No.1 panel
(See page SF−65 ).
(b) Connect between terminals THW and E2 of ECM connec-
tor.
HINT:
Engine coolant temp. sensor connector is disconnected. Be-
fore checking, do a visual and contact pressure check for the
ECM connector (See page IN−28).
(c) Turn ignition switch ON.
CHECK:
Read temperature value on the OBD II scan tool or TOYOTA
hand −held tester.
OK:
Temperature value: 140° C (284°F) or more
OK Open in harness between terminals E2 or THW, repair or replace harness.
NG
Confirm good connection at ECM.
If OK, replace ECM (See page IN−28).
4 Check for short in harness or ECM.
PREPARATION:
(a) Disconnect the engine coolant temp. sensor connector.
(b) Turn ignition switch ON.
CHECK:
Read temperature value on the OBD II scan tool or TOYOTA
hand−held tester.
OK:
Temperature value: − 40° C (− 40°F)
OK Replace engine coolant temp. sensor.
NG
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 470 of 1399
A00159
ON
Engine Coolant
Temp. Sensor ECM
5V
E2 E1
E5 connector
THW
BE6653
FI7056
P19798
−
DIAGNOSTICS ENGINE
DI−33
1996 LAND CRUISER (RM451U)
5 Check for short in harness or ECM.
PREPARATION:
(a) Remove instrument panel speaker No.1 panel
(See page SF−65 ).
(b) Disconnect the E5 connector of ECM.
HINT:
Engine coolant temp. sensor connector is disconnected.
(c) Turn ignition switch ON.
CHECK:
Read temperature value on the OBD II scan tool or TOYOTA
hand −held tester.
OK:
Temperature value: − 40° C (− 40°F)
OK Repair or replace harness or connector.
NG
Check and replace ECM (See page IN−28 ).
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 471 of 1399

DI−34
−
DIAGNOSTICS ENGINE
1996 LAND CRUISER (RM451U)
DTC P0116 Engine Coolant Temp. Circuit Range/ Performance Problem
CIRCUIT DESCRIPTION
Refer to DTC P0115 (Engine Coolant Temp. Circuit Malfunction) on page DI−30.
DTC No..DTC Detecting ConditionTrouble Area
P0116
If THW 10°C (50° F), 2 min. or more after starting engine,
engine coolant temp. sensor value is 35 °C (95° F) or less
(2 trip detection logic)
Engine coolant temp. sensor
Cooling system
If −7°C (19.4° F) THW < 10 °C (50° F), 5 min. or more after
starting engine, engine coolant temp. sensor value 35 °C
(95 °F) or less
(2 trip detection logic)
If THW < −7°C (19.4° F), 20 min. or more after starting engine,
engine coolant temp. sensor value is 35 °C (95° F) or less
(2 trip detection logic)
INSPECTION PROCEDURE
HINT:
If DTC P0115 (Engine Coolant Temp. Circuit Malfunction) and P0116 (Engine Coolant Temp. Circuit Range/
Performance) are output simultaneously, engine coolant temp. sensor circuit may be open.
Perform troubleshooting of DTC P0115 first.
1 Are there any other codes (besides DTC P0116) being output?
YES Go to relevant DTC chart.
NO
2 Check thermostat (See page CO−9 ).
NG Replace the thermostat.
OK
Replace engine coolant temp. sensor.