1995 SUBARU LEGACY light

[x] Cancel search: light

Page 721 of 2248

SUBARU LEGACY 1995  Service Repair Manual B: SERVICE DATA
ITEM STANDARD SERVICE LIMIT
Front brakePad thickness
(including back metal)17 mm (0.67 in) 7.5 mm (0.295 in)
Disc thickness 24 mm (0.94 in) 22 mm (0.87 in)
Disc runout—0.075 mm (0.00

Page 757 of 2248

SUBARU LEGACY 1995  Service Repair Manual B: DISASSEMBLY
1. PRECAUTIONS FOR DISASSEMBLING
1) Remove mud and dirt from the surface of brake master
cylinder.
2) Prepare tools necessary for disassembly operation, and
arrange them neatly on work

Page 758 of 2248

SUBARU LEGACY 1995  Service Repair Manual D: ASSEMBLY
1. PRECAUTIONS FOR ASSEMBLING
1) When assembling, be sure to use recommended brake
fluid.
2) Ensure that the inside wall of cylinder, pistons, and pis-
ton cups are free from dirt when ass

Page 760 of 2248

SUBARU LEGACY 1995  Service Repair Manual B4M0616A
B4M0617A
7) Adjust operating rod of brake booster.
Standard: L
145.3 mm (5.72 in)
If it is not in specified value, adjust it by adjusting brake
booster operating rod.
8) Measure the clearance

Page 761 of 2248

SUBARU LEGACY 1995  Service Repair Manual G4M0744
2. AIR TIGHTNESS CHECK
Start engine, and run it for 1 to 2 minutes, then turn it off.
Depress brake pedal several times applying the same
pedal force as that used in ordinary braking operation

Page 765 of 2248

SUBARU LEGACY 1995  Service Repair Manual G4M0426
7. Brake Hose
A: REMOVAL
1) Separate brake pipe from brake hose.
(Always use flare nut wrench and be careful not to deform
flare nut.)
2) Pull out clamp to remove brake hose.
3) Remove clamp a

Page 767 of 2248

SUBARU LEGACY 1995  Service Repair Manual C: INSTALLATION
1) Install PHV onto side frame.
Tightening torque:
18±5 N⋅m (1.8±0.5 kg-m, 13.0±3.6 ft-lb)
2) Connect brake pipes to PHV.
Tightening torque:
15
+3
�2N⋅m (1.5+0.3
�0.2kg-m, 10.8+

Page 785 of 2248

SUBARU LEGACY 1995  Service Repair Manual 2. CHECKING THE HYDRAULIC UNIT OPERATION BY
PRESSURE GAUGE
1) Remove the FL and FR pipes from the hydraulic unit.
G4M0460
2) Connect two pressure gauges to the hydraulic unit.
CAUTION:
Pressure gauge