1990 MAZDA 232 Workshop Manual Suplement

Page 177 of 677

MAZDA 232 1990  Workshop Manual Suplement F2 CONTROL SYSTEM 
Terminal voltage [BP TURBO] 
eminal input Output , 1 Connected to Test condition Correct voltage Remark 
IA - - Battery Constant Approx. 12V for backup 
15 0 Main relay OFF Approx.

Page 178 of 677

MAZDA 232 1990  Workshop Manual Suplement CONTROL SYSTEM F2 
Incorrect voltage Possible cause 
Always OV 
l ROOM 10A fuse burned l Open circuit in wiring from ROOM 10A fuse to ECU termrnal IA 
Always OV 
I l Main relay maifunctlon l Open or s

Page 179 of 677

MAZDA 232 1990  Workshop Manual Suplement F2 CONTROLSYSTEM 
erminat Input ’ Output Connected to Test condition Correct voltage Remark 
1N 0 I Throttle sensor Accelerator pedal released &low l.OV j Ignition switch 
(Idle switch) 
Accelerator

Page 180 of 677

MAZDA 232 1990  Workshop Manual Suplement CONTROL SYSTEM F2 
Incorrect voltage 
Always below 1 .OV Possible cause 
l Throttle sensor misadjustment l Short circuit in wiring from throttle sensor to ECU terminal IN l ECU malfunction 
Always app

Page 181 of 677

MAZDA 232 1990  Workshop Manual Suplement F2 CUNTRULSYSTEM 
‘erminal Input Output i Connected to Test condition Correct voltage Remark 
2A - - ’ Ground {Injector) 
Constant OV - 
2B - - I Ground (Output) 
Constant OV - 
2c , - - 1 Ground

Page 182 of 677

MAZDA 232 1990  Workshop Manual Suplement CUNTRUL SYSTEM F2 
Incorrect voltage Possible cause 
I 
Above Ok’ l Poor contact at ground terminal l Open crrcurt in wiring from ECU to ground 
Always approx. OV or approx. 2V 
l Refer to Code No.0

Page 183 of 677

MAZDA 232 1990  Workshop Manual Suplement F2 CONTROLSYSTEM 
Terminal I Input Output Connected to Test condition Correct voltage Remark 
25 0 
Overboost warning lgnltion switch ON Approx. 12V 
- 
buzzer 
2T 0 1 Solenoid valve 180 seconds atter

Page 184 of 677

MAZDA 232 1990  Workshop Manual Suplement CONTROLSYSTEM F2 
I 
7 
Incorrect voltage Possible cause 
Always OV l Open or short circuit in wjring from ECU terminal 2s to buzzer 
Always OV or approx. 12V 
1 l Refer to Code No.25 Troubieshootlng