ELECTRONIC CONTROL UNIT (ECU)
Removal & Installation
Information not available from manufacturer.
COOLANT TEMPERATURE SENSOR (CTS)
Removal & Installation
Drain cooling system. Remove air cleaner assembly. Disconnect
electrical connector and remove sensor from block. To install, reverse
removal procedure. Refill cooling system.
OXYGEN (O2) SENSOR
Removal & Installation
Raise and support vehicle. Disconnect electrical connector
from sensor. Remove sensor from exhaust manifold. Install and tighten
sensor to 35 ft. lbs. (47 N.m). Reconnect electrical connector. Lower
vehicle.
THROTTLE POSITION SENSOR (TPS)
Removal
Disconnect electrical connector from TPS. Bend lock tabs away
from retaining screws and remove screws. Remove TPS.
Installation
With throttle valve in normal closed position, install TPS.
Install TPS retaining screws. Perform OUTPUT CHECK.
NOTE: Throttle position sensor is nonadjustable. Only output
voltage can be monitored.
Output Check (Manual Transmission Only)
1) Connect negative lead of digital voltmeter to terminal "B"
and positive lead to terminal "A" of TPS connector. Do not disconnect
electrical connector. Insert leads through back of connector. It may
be necessary to remove throttle body from vehicle to gain access to
connector.
2) Turn ignition on, engine off. With throttle closed and
resting against idle stop, input voltage should be about 5 volts. Move
positive lead from terminal "B" to terminal "C" and read voltage
output. Output voltage should be about 0.8 volt with throttle closed
and resting against idle stop.
3) If voltage is not as specified, loosen lower retaining
screw and pivot sensor for large adjustments. Loosen upper retaining
screw and pivot sensor for small adjustments. Adjust sensor so output
voltage reading equals 16 percent of input voltage. If voltage
specifications cannot be obtained, replace sensor. Remove voltmeter.
Tighten screws and bend retaining tabs into position.
ALL OTHER SENSORS, SOLENOIDS & SWITCHES
Removal & Installation
Removal of sensors, switches, and solenoids is accomplished
by disconnecting the electrical and/or vacuum connectors and removing
or detaching the component. To install, reverse removal procedure.
TESTING
NOTE: Refer to Figs. 8-10 for Testing information.