TM-42
< SYSTEM DESCRIPTION >[CVT: RE0F10D]
DIAGNOSIS SYSTEM (TCM)
• When the self-diagnosis result is acceptable at the 2nd
trip (conforming to driving condition B), DTC of the
1st trip is erased.
COUNTER SYSTEM LIST
DRIVING CONDITION
Driving condition A
Driving condition A is the driving condition that provides warm-up.
In specific, count-up is performed when all of the following conditions are satisfied.
• Engine speed is 400 rpm or more.
• After start of the engine, the water temperature increased by 20 °C (36 °F) or more.
• Water temperature was 70 °C (158 °F) or more.
• The ignition switch was changed from ON to OFF.
NOTE:
• If the same malfunction is detected regardless of the driving condition, reset the A counter.
• When the above is satisfied without detecting t he same malfunction, count up the A counter.
• When MIL goes off due to the malfunction and the A counter reaches 40, the DTC is erased.
Driving condition B
Driving condition B is the driving condition that performs all diagnoses once.
In specific, count-up is performed when all of the following conditions are satisfied.
• Engine speed is 400 rpm or more.
• Water temperature was 70 °C (158 °F) or more.
• In closed loop control, vehicle speed of 70 – 120 km/h (43 – 75 MPH) continued for 60 seconds or more.
• In closed loop control, vehicle speed of 30 – 60 km/h (19 – 37 MPH) continued for 10 seconds or more.
• In closed loop control, vehicle speed of 4 km/h (2 MPH) or less and idle determination ON continued for 12
seconds or more.
• After start of the engine, 22 minutes or more have passed.
• The condition that the vehicle speed is 10 km/h (6 MPH) or more continued for 10 seconds or more in total.
• The ignition switch was changed from ON to OFF.
NOTE:
• If the same malfunction is detected regardless of the driving condition, reset the B counter.
• When the above is satisfied without detecting t he same malfunction, count up the B counter.
• When the B counter reaches 3 wit hout malfunction, MIL goes off.
• When the B counter is counted once without detecting the same malfunction after TCM memorizes DTC of
the 1st trip, DTC of the 1st trip is erased.
Item Driving condition Trip
MIL (OFF) B 3
DTC (clear) A 40
DTC at 1st trip (clear) B 1
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
TM-158
< DTC/CIRCUIT DIAGNOSIS >[CVT: RE0F10D]
P2813 SELECT SOLENOID
P2813 SELECT SOLENOID
DTC LogicINFOID:0000000009464099
DTC DETECTION LOGIC
NOTE:
DC stands for “DRIVING CYCLE” and indicates a seri es of driving cycle of “Ignition switch OFF → ON → driv-
ing → OFF”.
DTC CONFIRMATION PROCEDURE
CAUTION:
Be careful of the driving speed.
1.PREPARATION BEFORE WORK
DTC CONSULT screen terms
(Trouble diagnosis content) DTC detection condition Possible causes
P2813 SELECT SOLENOID
(Select solenoid) When any of 1, or 2 is satisfied:
1. When all the following conditions are es- tablished three times in 1DC
-Precondition
• DTC other than the applicable DTC is not detected.
• Throtte position: More than 6.27 deg.
• Vehicle speed: Less than 3 km/h (1 MPH)
• CVT fluid temperature: More than 20 °C
(68 °F)
• Selector lever: Other than P, N
• Turbine speed when performed N → D,
N (P) → R: More than 500 rpm
• TCM power supply voltage: More than 11 V
- Detection time
•N → D: 0.4 seconds
•N → R: 0.3 seconds
•P → R: 0.3 seconds
2. When all of the following conditions are satisfied and this state is maintained for
30 seconds:
- The counting of time continues while all of the following conditions are satisfied
and stops when the conditions become
unsatisfied (the count is maintained).
When accumulated time reaches 30 sec-
onds (Clutch is judged as engaged and
the count is reset.)
• Selector lever: Other than P, N
• Vehicle speed: Less than 3 km/h (1
MPH)
• Differences between primary pulley speed and secondary speed speed:
Less than 120 rpm
• Clutch instructions pressure: 0.95 MPa or more
• Differences between turbine speed and input speed speed: Less than 200 rpm
• Turbine speed – speed: More than 450
rpm
• DTC other than the applicable DTC is not detected.
• TCM power supply voltage: More than 11 V Select solenoid valve
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
TM-244
< SYSTEM DESCRIPTION >[CVT: RE0F10E]
DIAGNOSIS SYSTEM (TCM)
• When the self-diagnosis result is acceptable at the 2nd
trip (conforming to driving condition B), DTC of the
1st trip is erased.
COUNTER SYSTEM LIST
DRIVING CONDITION
Driving condition A
Driving condition A is the driving condition that provides warm-up.
In specific, count-up is performed when all of the following conditions are satisfied.
• Engine speed is 400 rpm or more.
• After start of the engine, the water temperature increased by 20 °C (36 °F) or more.
• Water temperature was 70 °C (158 °F) or more.
• The ignition switch was changed from ON to OFF.
NOTE:
• If the same malfunction is detected regardless of the driving condition, reset the A counter.
• When the above is satisfied without detecting t he same malfunction, count up the A counter.
• When MIL goes off due to the malfunction and the A counter reaches 40, the DTC is erased.
Driving condition B
Driving condition B is the driving condition that performs all diagnoses once.
In specific, count-up is performed when all of the following conditions are satisfied.
• Engine speed is 400 rpm or more.
• Water temperature was 70 °C (158 °F) or more.
• In closed loop control, vehicle speed of 70 – 120 km/h (43 – 75 MPH) continued for 60 seconds or more.
• In closed loop control, vehicle speed of 30 – 60 km/h (19 – 37 MPH) continued for 10 seconds or more.
• In closed loop control, vehicle speed of 4 km/h (2 MPH) or less and idle determination ON continued for 12
seconds or more.
• After start of the engine, 22 minutes or more have passed.
• The condition that the vehicle speed is 10 km/h (6 MPH) or more continued for 10 seconds or more in total.
• The ignition switch was changed from ON to OFF.
NOTE:
• If the same malfunction is detected regardless of the driving condition, reset the B counter.
• When the above is satisfied without detecting t he same malfunction, count up the B counter.
• When the B counter reaches 3 wit hout malfunction, MIL goes off.
• When the B counter is counted once without detecting the same malfunction after TCM memorizes DTC of
the 1st trip, DTC of the 1st trip is erased.
Item Driving condition Trip
MIL (OFF) B 3
DTC (clear) A 40
DTC at 1st trip (clear) B 1
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
TM-360
< DTC/CIRCUIT DIAGNOSIS >[CVT: RE0F10E]
P2813 SELECT SOLENOID
P2813 SELECT SOLENOID
DTC LogicINFOID:0000000009464316
DTC DETECTION LOGIC
NOTE:
DC stands for “DRIVING CYCLE” and indicates a seri es of driving cycle of “Ignition switch OFF → ON → driv-
ing → OFF”.
DTC CONFIRMATION PROCEDURE
CAUTION:
Be careful of the driving speed.
1.PREPARATION BEFORE WORK
DTC CONSULT screen terms
(Trouble diagnosis content) DTC detection condition Possible causes
P2813 SELECT SOLENOID
(Select solenoid) When any of 1, or 2 is satisfied:
1. When all the following conditions are es- tablished three times in 1DC
-Precondition
• DTC other than the applicable DTC is not detected.
• Throtte position: More than 6.27 deg.
• Vehicle speed: Less than 3 km/h (1 MPH)
• CVT fluid temperature: More than 20 °C
(68 °F)
• Selector lever: Other than P, N
• Turbine speed when performed N → D,
N (P) → R: More than 500 rpm
• TCM power supply voltage: More than 11 V
- Detection time
•N → D: 0.4 seconds
•N → R: 0.3 seconds
•P → R: 0.3 seconds
2. When all of the following conditions are satisfied and this state is maintained for
30 seconds:
- The counting of time continues while all of the following conditions are satisfied
and stops when the conditions become
unsatisfied (the count is maintained).
When accumulated time reaches 30 sec-
onds (Clutch is judged as engaged and
the count is reset.)
• Selector lever: Other than P, N
• Vehicle speed: Less than 3 km/h (1
MPH)
• Differences between primary pulley speed and secondary speed speed:
Less than 120 rpm
• Clutch instructions pressure: 0.95 MPa or more
• Differences between turbine speed and input speed speed: Less than 200 rpm
• Turbine speed – speed: More than 450
rpm
• DTC other than the applicable DTC is not detected.
• TCM power supply voltage: More than 11 V Select solenoid valve
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
WCS
DIAGNOSIS SYSTEM (METER)WCS-9
< SYSTEM DESCRIPTION >
C
D E
F
G H
I
J
K L
M B
A
O P
DIAGNOSIS SYSTEM (METER)
DescriptionINFOID:0000000009941189
COMBINATION METER SE LF-DIAGNOSIS MODE
The following meter functions can be checked during Combination Meter Self-Diagnosis Mode:
• Pointer sweep of speedometer, tachometer and gauges.
• Illumination of all LCD segments and color patterns for meter displays.
• Illumination of all lamps/LEDs that are controlled by the combination meter (regardless of switch status).
STARTING COMBINATION METER SELF-DIAGNOSIS MODE
NOTE:
• Check combination meter power supply and ground circuits if self-diagnosis mode does not start. Refer to
MWI-58, "COMBINATION METER : Diagnosis Procedure"
. Replace combination meter if power supply and
ground circuits are found to be normal and self-diagnosis mode does not start. Refer to MWI-82, "Removal
and Installation".
• Combination meter self-diagnosis mode will function with the ignition switch in ON. Combination meter self-
diagnosis mode will exit upon turning the ignition switch to OFF.
How to Initiate Se lf-Diagnosis Mode
1. Press and hold the trip reset switch while turning the ignition switch ON. After 2 seconds release trip reset
switch, then press the trip reset switch 3 times withi n 7 seconds after the ignition switch is turned ON.
2. When the diagnosis function is activated, the meter illuminates all of the following:
• Warning lights/indicators.
• Meter assembly.
• Information display color bars red, green, blue and white (1).
• Odometer, trip A/B odometers and CVT indicator LCD display segments (2).
3. Pressing and holding the trip reset switch performs the pointer sweep test.
CONSULT Function (METER/M&A)INFOID:0000000009941190
CAUTION:
After disconnecting the CONSULT vehicle interface (VI) from the data link connector, the ignition must
be cycled OFF → ON (for at least 5 seconds) → OFF. If this step is not performed, the BCM may not go
to ”sleep mode”, potentiall y causing a discharged battery and no-start condition.
APPLICATION ITEMS
CONSULT can display each diagnostic item using the diagnostic test modes shown.
SELF DIAG RESULT
AWNIA2543GB
METER/M&A Diagnosis mode Description
SELF DIAGNOSTIC RESULT Displays combination meter self-diagnosis results. DATA MONITOR Displays combination meter input/output data in real time.
WARNING HISTORY Lighting history of the warning lamp and indicator lamp can be checked.
CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read.
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM