Page 57 of 63
83A-57
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 5
CONTINUED 1
With the ignition off, disconnect the fuel sender connector,
component code 199 and then check the resistance using a
multimeter.
Replace the sender, component
code 833 (see MR 370,
Mechanical, 19C, Fuel tank,
Sender: Removal - Refitting). Is the measured value above or equal to 290 ΩΩ Ω Ω
?
Compare the value measured to the value supplied by the CLIP
tool.
Is the value measured and the value provided by the CLIP
tool the same as or approximately ± 5 ΩΩ Ω Ω
?
Contact the Techline.
A
NO
NO
YES
NOB
YES
Page 58 of 63
83A-58
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 5
CONTINUED 2
Check the continuity, insulation and absence of interference
resistance on the following connections:
•41A between components 247 and 199,
•41B between components 247 and 199.
Are the checks correct?
If the connection or connections are faulty and there is a repair procedure
(see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the wiring.
Is the fault still present?
The problem disappears.
B
NO
NOC
YES
D
C
NO
YESD
NO
Page 59 of 63
83A-59
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 5
CONTINUED 3
Measure the resistance of the sender and the wiring via the connector,
on the instrument panel side.
Is the value measured and the value provided by the CLIP tool the
same as or approximately ± 5 ΩΩ Ω Ω
?Contact the Techline.
Replace the instrument panel, component code 247 (see MR 370,
Mechanical, 83A, Instrument panel, Instrument panel: Removal -
Refitting).
Is the fault still present?Contact the Techline.
The problem disappears.
D
YES
YES
NO
YES
NO
Page 60 of 63

83A-60
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 6Fault with no warning given by warning light (addition of fuel
since the fault)
NOTESPut the vehicle in + after ignition.
See Wiring Diagram Technical Note for Scénic II.
Check the instrument panel warning lights, component
code 247.
Does the fuel warning light illuminate for 3
seconds when + after ignition is switched on?Replace the instrument panel,
component code 247 (see MR 370,
Mechanical, 83A, Instrument panel,
Instrument panel: Removal -
Refitting).
With the ignition off, disconnect the fuel sender
connector, component code 199 and then check the
resistance using a multimeter.
Compare the value measured to the value supplied by
the CLIP tool.
Is the value measured and the value provided by
the CLIP tool the same as or approximately ± 5 ΩΩ Ω Ω
?
Contact the Techline.
NO
YES
NOB
YES
TDB_V08_ALP6/TDB_V0C_ALP6
Page 61 of 63
83A-61
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 6
CONTINUED 1
Check the continuity, insulation and absence of interference
resistance on the following connections:
•41A between components 247 and 199,
•41B between components 247 and 199.
Are the checks correct?
If the connection or connections are faulty and there is a repair procedure
(see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the wiring.
Is the fault still present?Contact the Techline.
The problem disappears.
B
NO
NOD
YES
E
D
NO
YES
NO
Page 62 of 63
83A-62
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 6
CONTINUED 2
Measure the resistance of the sender and the wiring via the
connector, on the instrument panel side.
Is the value measured and the value provided by the CLIP
tool the same as or approximately ± 5 ΩΩ Ω Ω
?Contact the Techline.
Replace the instrument panel, component code 247 (see MR
370, Mechanical, 83A, Instrument panel, Instrument
panel: Removal - Refitting).
Is the fault still present?The problem disappears.
Contact the Techline.
E
YES
YES
NO
NO
YES
Page 63 of 63
83A-63
AFTER REPAIRRepeat the conformity check from the start.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 7 Fault with delayed warning
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
Ask the customer the distance travelled since the
warning appeared until the fault occurred.
Did the fault take place after travelling more than
30 miles (50 Kms)?Explain to the customer that the guaranteed
distance is 30 miles (50 kms) from the
warning.
Has the customer added any fuel since the fault?See ALP6 Fault with no warning given
by warning light (addition of fuel since
the fault).
See ALP5 Fault with no warning given by
warning light (no addition of fuel since the fault).
YES
NO
YES
NO
TDB_V08_ALP7/TDB_V0C_ALP7