Page 49 of 63

83A-49
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2 The fuel level indicator does not display full
NOTESThe fuel tank must be filled with the ignition switched off (advise the customer to remove
the key).
Ideally the customer must fill the tank with at least 15 litres.
See Wiring Diagram Technical Note for Scénic II.
Ask the customer if the tank is filled up under the
following conditions:
–the customer filled the tank up to the 3
rd cut-out
–the customer has changed filling station
–the customer filled the tank in a flat-level station (not
on a slope).
Did the customer fill the tank while observing all of
these conditions?Ask the customer to return just after
having filled the tank under the conditions
mentioned above.
NO
YES
A
TDB_V08_ALP2/TDB_V0C_ALP2
Page 50 of 63
83A-50
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 1
With the ignition off, disconnect the fuel sender
connector, component code 199 and then check
the resistance using a multimeter.
The value should be: 54 ΩΩ Ω Ω
.
Is the value measured less than 54 ΩΩ Ω Ω
?Replace the fuel sender, component code
199 (see MR 370, Mechanical, 19C, Fuel
tank, Sender: Removal - Refitting).
If the fault is still present, contact Techline.
Compare the value measured to the value supplied
by the CLIP tool.
Is the value measured and the value provided
by the CLIP tool the same as or approximately
± 5 ΩΩ Ω Ω
?
A
YES
NO
YES
NOC
YES
B
Page 51 of 63

83A-51
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 2
Check the continuity, insulation and absence of
interference resistance on the following
connections:
•41A between components 247 and 199,
•41B between components 247 and 199.
Are the checks correct?
Measure the resistance of the sender and the wiring
using a multimeter via the connector, on the
instrument panel side.
Is the value measured and the value provided by
the CLIP tool the same as or approximately
± 5 ΩΩ Ω Ω
?Contact the Techline.
Replace the instrument panel, component code 247
(see MR 370, Mechanical, 83A, Instrument panel,
Instrument panel: Removal - Refitting).
Is the fault still present?The problem disappears.
C
NO
NOD
YES
YES
NO
NO
YES
B
Page 52 of 63
83A-52
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 3
If the connection or connections are faulty and
there is a repair procedure (see Technical Note
6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring,
otherwise replace the wiring.
Is the fault still present?
The problem disappears.
D
NO
YESB
NO
Page 53 of 63
83A-53
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 2
CONTINUED 4
Use the CLIP tool to check that the needle or
digital display type indicators are working correctly
using command AC008 Instrument panel needle
gauges.
Is the result of the check correct?Contact the Techline.
If the needle or display indicator test is incorrect,
replace the instrument panel, component code
247 (see MR 370, Mechanical, 83A, Instrument
panel, Instrument panel: Removal - Refitting).
Is the fault still present?The problem disappears.
Contact the Techline.
B
YES
YES
NO
NO
YES
Page 54 of 63
83A-54
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 3 Addition of fuel not registered (not full)
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
Consult the interpretation of ALP2 The fuel level indicator does not display full.
TDB_V08_ALP3/TDB_V0C_ALP3
Page 55 of 63

83A-55
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 4 Display jammed when driving (not mechanical)
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
For economical driving, the blocks on the display may remain illuminated or the needle
may remain jammed up to 120 miles (200 kms).
Check that there is no mechanical jamming.
If the fault is on the block at the top of the display or the needle is jammed at full:
check that the customer has travelled a sufficient amount of Km (miles) for the block at the top of the display to
go out or for the needle to move from the full section.
Check that the customer has not exceeded 3 filler cut-outs when filling the tank with fuel.
If the fault is still present or if the needle or the display is jammed in any position other than full, contact the Techline.
TDB_V08_ALP4/TDB_V0C_ALP4
Page 56 of 63

83A-56
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V8 MR-372-J84-83A000$945.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
ALP 5Fault with no warning given by warning light (no addition of fuel
since the fault)
NOTESPut the vehicle in + after ignition.
See Wiring Diagram Technical Note for Scénic II.
Check the instrument panel warning lights, component code
247.Replace the instrument panel,
component code 247 (see MR
370, Mechanical, 83A,
Instrument panel, Instrument
panel: Removal - Refitting). Does the fuel warning light illuminate for 3 seconds when
+ after ignition is switched on?
Record the resistance value provided by the CLIP tool.
Compare the value from the CLIP tool with the warning
resistance, which is 290 ΩΩ Ω Ω
.
Is this value above or equal to 290 ΩΩ Ω Ω
?Contact the Techline.
Rock the vehicle and check whether the resistance changes by
± 5 ΩΩ Ω Ω
.
Is there a change in the resistance value?Contact the Techline.
NO
YES
YES
NO
YES
NO
A
TDB_V08_ALP5/TDB_V0C_ALP5