Page 17 of 63

83A-17
MR-372-J84-83A000$378.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of faults83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
DF016
CONTINUED
CC
NOTESNone.
Look for possible damage to the harness, and check the connection and condition of the oil level sensor and its
connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair) repair the wiring, otherwise replace it.
Check the insulation and continuity of the following connections:
Vdiag 44 UPC:
Oil level sensor track 1 track 11, black connector (PEM), Protection
and Switching Unit
Oil level sensor track 2 track 10, black connector (PEM), Protection
and Switching Unit
Instrument panel connection track 10 track 5, black connector (PEH), Protection
and Switching Unit
Instrument panel track 3 track 4, black connector (PEH), Protection
and Switching Unit
UPC Vdiag 48:
Oil level sensor track 1 track 11, connector MT1, Protection and
Switching Unit
Oil level sensor track 2 track 12, connector MT1, Protection and
Switching Unit
Instrument panel connection track 10 track 6, connector CT1, Protection and
Switching Unit
Instrument panel track 3 track 5, connector CT1, Protection and
Switching Unit
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault becomes an open circuit fault, move to the next step of the fault finding.
Measure the resistance between tracks 1 and 2 of the oil level sensor.
Replace the oil level sensor if the resistance is not between 3 and 20 ΩΩ Ω Ω
.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
Page 18 of 63
83A-18
MR-372-J84-83A000$378.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of faults83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
* EEPROM = Computer memory.DF018
PRESENT
INSTRUMENT PANEL
1.DEF: Computer fault
NOTESSpecial notes:
A computer fault is declared when the instrument panel detects an odometer
management fault in the EEPROM*. The mileage is no longer guaranteed to be
correct.
Contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
TDB_V08_DF018P/ TDB_V0C_DF018P
Page 19 of 63

83A-19
MR-372-J84-83A000$378.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of faults83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
DF019
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Voltage too low
2.DEF: Voltage too high
3.DEF: Excess voltage
NOTESNone.
1.DEF
NOTESSpecial note:
The fault is declared present if the battery voltage is less
than 8 V.
Manipulate the wiring harness between the instrument panel and the battery in order to produce a change in fault
status (Present → Stored).
Look for any harness damage, and check the connection and condition of the battery and its connections.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the condition of the battery and the charging circuit (see Technical Note 6014A, Checking the
charging circuit).
Check the condition of the vehicle earths.
Check for + 12 V on track 13 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
With the ignition on, check for + 12 V on track 14 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check for earth on track 1 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
TDB_V08_DF019/ TDB_V0C_DF019
Page 20 of 63

83A-20
MR-372-J84-83A000$378.mif
V8
INSTRUMENT PANEL
Fault finding - Interpretation of faults83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
DF019
CONTINUED
2.DEF
3.DEF
NOTESSpecial note:
The fault is declared present if the battery voltage is greater
than 16 V.
Manipulate the wiring harness between the instrument panel and the battery in order to produce a change in fault
status (Present → Stored).
Look for any harness damage, and check the connection and condition of the battery and its connections.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check the condition of the battery and the charging circuit (see Technical Note 6014A, Checking the
charging circuit).
Check the condition of the vehicle earths.
Check for + 12 V on track 13 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
With the ignition on, check for + 12 V on track 14 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
Check for earth on track 1 of the instrument panel.
If there is a repair method (see Technical note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
Page 21 of 63

83A-21
MR-372-J84-83A000$441.mif
V8
83A
INSTRUMENT PANEL
Fault finding - Conformity check
MAIN COMPUTER STATUSES AND PARAMETERS
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Ignition on, engine off.
Order FunctionParameter, Status
Check or ActionDisplay and notes Fault finding
1
SupplyPR110:Battery voltage11.5 V < PR110 < 16 VIn the event of a fault, consult
the interpretation of fault
DF019 Battery voltage.
2ET002:+ 12 V after
ignitionAbsent
PresentIn the event of a fault, refer to
the interpretation of status
ET002 + 12 V after ignition.
3
BrakeET097:Parking brakeApplied
ReleasedIn the event of a fault, consult
the interpretation of status
ET097 Parking brake.
4ET066:Brake fluid level
light alertIndicates the brake
fluid level.
PRESENT: Level too
low
ABSENT: Level correctIn the event of a fault, consult
the interpretation of status
ET066 Brake fluid level light
warning.
5Lighting PR111:Lighting dimmer
voltageIgnition on, dipped
headlights lit.
0.3 V < PR111 < 7 VIf the fault is still present,
contact Techline.
6Oil ET096:Oil pressure
contactOpen: indicator light off
Closed: indicator light
onIn the event of a fault, consult
the interpretation of status
ET096 Oil pressure contact.
7
Seat beltET098:Driver's seat belt
contactPresent (fastened)
AbsentIn the event of a fault, consult
the interpretation of status
ET098 Driver's seat belt
contact.
8ET062:Seat belt alarmOff
onIn the event of a fault, consult
the interpretation of status
ET098 Driver's seat belt
contact and of command
AC009 Instrument panel
indicator lights.
TDB_V08_CCONF /TDB_V0C_CCONFTDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
MR-372-J84-83A000$441.mif
Page 22 of 63
83A-22
MR-372-J84-83A000$441.mif
V8
INSTRUMENT PANEL
Fault finding - Conformity check83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
GAUGES
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Ignition on, engine off.
Order FunctionParameter, Status
Check or ActionDisplay and notes Fault finding
1
FuelPR115:LPG fuel levelIndicates the fuel level in the
tank.
PR115 = 0 l if vehicle not
equippedIn the event of a fault,
consult the interpretation
of parameter PR115 LPG
fuel level.
2PR002:Fuel sender
resistance In reserve: 290 ΩΩ Ω Ω
Full: 54 ΩΩ Ω ΩIn the event of a fault,
consult the interpretation
of fault DF007 Fuel
sender circuit. 3PR035:Fuel levelIndicates the fuel level in the
tank.
Page 23 of 63

83A-23
MR-372-J84-83A000$441.mif
V8
INSTRUMENT PANEL
Fault finding - Conformity check83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
DISPLAY
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Ignition on, engine off.
Order FunctionParameter, Status
Check or ActionDisplay and notes Fault finding
1Vehicle
speedPR099:Vehicle speedX mph (km/h)In the event of a fault, consult
the interpretation of parameter
PR099 Vehicle speed.
2
EnginePR116:Engine speedX rpmIn the event of a fault, consult
the interpretation of parameter
PR116 Engine speed.
3PR027:Coolant
temperature"X" ˚CIn the event of a fault, consult
the interpretation of parameter
PR027 Coolant temperature.
4
LightingPR111:Lighting dimmer
voltageIgnition on, dipped
headlights lit.
0.3 V < PR111 < 7 VIn the event of a fault, contact
the Techline.
5AC009:Instrument panel
warning lightsThe command lights
up all the indicator
lights at the same
time.In the event of a fault, consult
the interpretation of commands
AC009 Instrument panel
warning lights.
6AC010:LightingThe lighting intensity
will vary to 50% then
100% of its maximum
intensity for
5 seconds each time.In the event of a fault, consult
the interpretation of commands
AC010 Lighting.
7 Needle
gaugesAC008:Instrument panel
needle gaugesInstrument panel
needle gauge control.In the event of a fault, consult
the interpretation of command
AC008 Instrument panel
needles.
8Display AC007:DisplayThe display shows the
mileage as well as the
range.
All areas of the display
must light up at the
same time.In the event of a fault, consult
the interpretation of command
AC007 Display.
9Symbol
displayAC011:Symbol displayThe symbol display
shows the status of
the opening elements
and the tyre pressure.In the event of a fault, consult
the interpretation of command
AC011 Symbol display.
Page 24 of 63

83A-24
MR-372-J84-83A000$441.mif
V8
INSTRUMENT PANEL
Fault finding - Conformity check83A
TDB ph2 (EG/MG)
Prog version: 04xx
Vdiag No.: 08, 0C
MILEOMETER
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Ignition on, engine off.
Order FunctionParameter, Status
Check or ActionDisplay and notes Fault finding
1Odometer PR009:OdometerIndicates the counter
value in km.
If the fault is still present,
contact Techline. 2
Oil change
intervalPR007:Oil service
interval: current
value in kmIndicates the distance
to the next oil service
in km (this value must
be less than or equal
to the oil service
interval).
3PR008:Oil service
interval: actual
value in monthsIndicates the time
remaining to the oil
service in months (this
value must be less
than or equal to the
frequency).
4
Oil change
frequencyPR005:Oil change
frequency in
miles (kms)Indicates the oil
change frequency in
miles (kms)
(e.g.: 18,000 miles
(30,000 km))
5PR006:Oil change
frequency in
months.Indicates the oil
change frequency in
months
(e.g.: 24 months)